The accuracy of a method for printing three-dimensional spinal models.
To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology...
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Public Library of Science (PLoS)
2015-01-01
|
Series: | PLoS ONE |
Online Access: | http://europepmc.org/articles/PMC4411119?pdf=render |
_version_ | 1818200127056117760 |
---|---|
author | Ai-Min Wu Zhen-Xuan Shao Jian-Shun Wang Xin-Dong Yang Wan-Qing Weng Xiang-Yang Wang Hua-Zi Xu Yong-Long Chi Zhong-Ke Lin |
author_facet | Ai-Min Wu Zhen-Xuan Shao Jian-Shun Wang Xin-Dong Yang Wan-Qing Weng Xiang-Yang Wang Hua-Zi Xu Yong-Long Chi Zhong-Ke Lin |
author_sort | Ai-Min Wu |
collection | DOAJ |
description | To study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined.Forty-five computed tomography (CT) scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again.Paired t-tests were used to determine the significance, set to P<0.05, of all parameter data from the radiographic images and 3D printed models. Furthermore, 88.6% of all parameters of the cervical spine, 90% of all parameters of the thoracic spine, and 94% of all parameters of the lumbar spine had Intraclass Correlation Coefficient (ICC) values >0.800. The other ICC values were <0.800 and >0.600; none were <0.600.In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research. |
first_indexed | 2024-12-12T02:32:43Z |
format | Article |
id | doaj.art-222ddab62c73468f8e1c6f37449374a3 |
institution | Directory Open Access Journal |
issn | 1932-6203 |
language | English |
last_indexed | 2024-12-12T02:32:43Z |
publishDate | 2015-01-01 |
publisher | Public Library of Science (PLoS) |
record_format | Article |
series | PLoS ONE |
spelling | doaj.art-222ddab62c73468f8e1c6f37449374a32022-12-22T00:41:21ZengPublic Library of Science (PLoS)PLoS ONE1932-62032015-01-01104e012429110.1371/journal.pone.0124291The accuracy of a method for printing three-dimensional spinal models.Ai-Min WuZhen-Xuan ShaoJian-Shun WangXin-Dong YangWan-Qing WengXiang-Yang WangHua-Zi XuYong-Long ChiZhong-Ke LinTo study the morphology of the human spine and new spinal fixation methods, scientists require cadaveric specimens, which are dependent on donation. However, in most countries, the number of people willing to donate their body is low. A 3D printed model could be an alternative method for morphology research, but the accuracy of the morphology of a 3D printed model has not been determined.Forty-five computed tomography (CT) scans of cervical, thoracic and lumbar spines were obtained, and 44 parameters of the cervical spine, 120 parameters of the thoracic spine, and 50 parameters of the lumbar spine were measured. The CT scan data in DICOM format were imported into Mimics software v10.01 for 3D reconstruction, and the data were saved in .STL format and imported to Cura software. After a 3D digital model was formed, it was saved in Gcode format and exported to a 3D printer for printing. After the 3D printed models were obtained, the above-referenced parameters were measured again.Paired t-tests were used to determine the significance, set to P<0.05, of all parameter data from the radiographic images and 3D printed models. Furthermore, 88.6% of all parameters of the cervical spine, 90% of all parameters of the thoracic spine, and 94% of all parameters of the lumbar spine had Intraclass Correlation Coefficient (ICC) values >0.800. The other ICC values were <0.800 and >0.600; none were <0.600.In this study, we provide a protocol for printing accurate 3D spinal models for surgeons and researchers. The resulting 3D printed model is inexpensive and easily obtained for spinal fixation research.http://europepmc.org/articles/PMC4411119?pdf=render |
spellingShingle | Ai-Min Wu Zhen-Xuan Shao Jian-Shun Wang Xin-Dong Yang Wan-Qing Weng Xiang-Yang Wang Hua-Zi Xu Yong-Long Chi Zhong-Ke Lin The accuracy of a method for printing three-dimensional spinal models. PLoS ONE |
title | The accuracy of a method for printing three-dimensional spinal models. |
title_full | The accuracy of a method for printing three-dimensional spinal models. |
title_fullStr | The accuracy of a method for printing three-dimensional spinal models. |
title_full_unstemmed | The accuracy of a method for printing three-dimensional spinal models. |
title_short | The accuracy of a method for printing three-dimensional spinal models. |
title_sort | accuracy of a method for printing three dimensional spinal models |
url | http://europepmc.org/articles/PMC4411119?pdf=render |
work_keys_str_mv | AT aiminwu theaccuracyofamethodforprintingthreedimensionalspinalmodels AT zhenxuanshao theaccuracyofamethodforprintingthreedimensionalspinalmodels AT jianshunwang theaccuracyofamethodforprintingthreedimensionalspinalmodels AT xindongyang theaccuracyofamethodforprintingthreedimensionalspinalmodels AT wanqingweng theaccuracyofamethodforprintingthreedimensionalspinalmodels AT xiangyangwang theaccuracyofamethodforprintingthreedimensionalspinalmodels AT huazixu theaccuracyofamethodforprintingthreedimensionalspinalmodels AT yonglongchi theaccuracyofamethodforprintingthreedimensionalspinalmodels AT zhongkelin theaccuracyofamethodforprintingthreedimensionalspinalmodels AT aiminwu accuracyofamethodforprintingthreedimensionalspinalmodels AT zhenxuanshao accuracyofamethodforprintingthreedimensionalspinalmodels AT jianshunwang accuracyofamethodforprintingthreedimensionalspinalmodels AT xindongyang accuracyofamethodforprintingthreedimensionalspinalmodels AT wanqingweng accuracyofamethodforprintingthreedimensionalspinalmodels AT xiangyangwang accuracyofamethodforprintingthreedimensionalspinalmodels AT huazixu accuracyofamethodforprintingthreedimensionalspinalmodels AT yonglongchi accuracyofamethodforprintingthreedimensionalspinalmodels AT zhongkelin accuracyofamethodforprintingthreedimensionalspinalmodels |