DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV

The methods to identify types of phase-to-phase short circuits that can be used to improve technical excellence by speed-current line protection of distribution networks of 6–35 kV are considered. As a result of the assessment of the appropriateness of their application in current protection, the ch...

Full description

Bibliographic Details
Main Authors: F. A. Romaniuk, E. V. Buloichik, O. A. Huryanchyk, M. A. Shevaldin
Format: Article
Language:Russian
Published: Belarusian National Technical University 2017-11-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1093
_version_ 1826556442549682176
author F. A. Romaniuk
E. V. Buloichik
O. A. Huryanchyk
M. A. Shevaldin
author_facet F. A. Romaniuk
E. V. Buloichik
O. A. Huryanchyk
M. A. Shevaldin
author_sort F. A. Romaniuk
collection DOAJ
description The methods to identify types of phase-to-phase short circuits that can be used to improve technical excellence by speed-current line protection of distribution networks of 6–35 kV are considered. As a result of the assessment of the appropriateness of their application in current protection, the choice was made in favor of the method based on the control of the relative current unbalance. The influence of contact resistances and load currents of various levels on the magnitude and character of the change of relative unbalance taking into account the errors of measuring transformers of current has been studied with the aid of the method of numerical experiment. It is demonstrated that in a lot of cases of arch short circuits in the loaded power line and in idle mode, the control only asymmetry is insufficient for reliable determination of the type of damage. A better algorithm has been proposed for determining phase-to-phase short circuit based on the control and the analysis of the two relative unbalance currents determined by the current values of the differences of the phase currents of the line. Its serviceability was evaluated. It was found out that in all the modes being considered, the proposed method – when boundary conditions are properly chosen – makes it possible to fix three-phase and two-phase short circuit on the protected line, and in the area of remote redundancy. The dynamic properties of the proposed method are investigated for different modes of the line. It is established that in the worst case, the determining of the damage is provided during the time not exceeding 25 ms.
first_indexed 2024-04-10T02:52:53Z
format Article
id doaj.art-2246bc67d6f84c06bde40b4f4f82e746
institution Directory Open Access Journal
issn 1029-7448
2414-0341
language Russian
last_indexed 2025-03-14T08:12:46Z
publishDate 2017-11-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj.art-2246bc67d6f84c06bde40b4f4f82e7462025-03-02T13:14:26ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412017-11-0160649750410.21122/1029-7448-2017-60-6-497-5041054DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KVF. A. Romaniuk0E. V. Buloichik1O. A. Huryanchyk2M. A. Shevaldin3Belarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityBelarusian National Technical UniversityThe methods to identify types of phase-to-phase short circuits that can be used to improve technical excellence by speed-current line protection of distribution networks of 6–35 kV are considered. As a result of the assessment of the appropriateness of their application in current protection, the choice was made in favor of the method based on the control of the relative current unbalance. The influence of contact resistances and load currents of various levels on the magnitude and character of the change of relative unbalance taking into account the errors of measuring transformers of current has been studied with the aid of the method of numerical experiment. It is demonstrated that in a lot of cases of arch short circuits in the loaded power line and in idle mode, the control only asymmetry is insufficient for reliable determination of the type of damage. A better algorithm has been proposed for determining phase-to-phase short circuit based on the control and the analysis of the two relative unbalance currents determined by the current values of the differences of the phase currents of the line. Its serviceability was evaluated. It was found out that in all the modes being considered, the proposed method – when boundary conditions are properly chosen – makes it possible to fix three-phase and two-phase short circuit on the protected line, and in the area of remote redundancy. The dynamic properties of the proposed method are investigated for different modes of the line. It is established that in the worst case, the determining of the damage is provided during the time not exceeding 25 ms.https://energy.bntu.by/jour/article/view/1093power linecurrent protectiontechnical excellencerelative unbalancetype of short circuitcontact resistanceperformance
spellingShingle F. A. Romaniuk
E. V. Buloichik
O. A. Huryanchyk
M. A. Shevaldin
DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
power line
current protection
technical excellence
relative unbalance
type of short circuit
contact resistance
performance
title DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV
title_full DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV
title_fullStr DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV
title_full_unstemmed DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV
title_short DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV
title_sort determining a type of a damage in the current protection of power lines of 6 35 kv
topic power line
current protection
technical excellence
relative unbalance
type of short circuit
contact resistance
performance
url https://energy.bntu.by/jour/article/view/1093
work_keys_str_mv AT faromaniuk determiningatypeofadamageinthecurrentprotectionofpowerlinesof635kv
AT evbuloichik determiningatypeofadamageinthecurrentprotectionofpowerlinesof635kv
AT oahuryanchyk determiningatypeofadamageinthecurrentprotectionofpowerlinesof635kv
AT mashevaldin determiningatypeofadamageinthecurrentprotectionofpowerlinesof635kv