Application of Transverse Grain-Cooling Ventilation for Warehouse by Subregion in High Temperature and Humidity Area

This paper studies transverse grain-cooling ventilation technology applied to 24m long-span warehouse in high temperature and humidity area. Application effect of transverse grain-cooling ventilation technology was evaluated by adopting district cooling ventilation mode. The results showed that the...

Full description

Bibliographic Details
Main Authors: LI Qian-qian, YANG Dong-ping, HUANG Cheng-bing, SHI Tian-yu, LIU Hui-biao
Format: Article
Language:English
Published: Academy of National Food and Strategic Reserves Administration 2022-01-01
Series:Liang you shipin ke-ji
Subjects:
Online Access:http://lyspkj.ijournal.cn/lyspkj/article/abstract/20220133?st=article_issue
Description
Summary:This paper studies transverse grain-cooling ventilation technology applied to 24m long-span warehouse in high temperature and humidity area. Application effect of transverse grain-cooling ventilation technology was evaluated by adopting district cooling ventilation mode. The results showed that the transverse grain-cooling ventilation by sub region in large-span warehouse had the advantages of faster cooling rate, better ventilation uniformity, remarkable water retention effect and lower consuming power. The temperature gradient along the cool air direction was less than 0.22 ℃/m. The ventilation water loss rate was 0.1% and consuming power rate was 0.10 kw·h/(t·℃). The consuming power rate is only 20% of the maximum consuming power rate index of 0.5 kw·h/(t·℃) which is defined in the “Grain and oil storage—Technology regulation of application of grain chiller”, (GB/T 29374—2012).
ISSN:1007-7561