Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysis

Three dimensional (3D) culture of mammalian cells is emerging as a powerful new tool to understand organogenesis as well as serve as models for diseases with implications for therapeutic evaluation. 3D cultures are referred to variously as spheroid, organoids or embryoid bodies. While many methods e...

Full description

Bibliographic Details
Main Authors: Ross Ferguson, Vasanta Subramanian
Format: Article
Language:English
Published: Elsevier 2018-04-01
Series:Stem Cell Research
Online Access:http://www.sciencedirect.com/science/article/pii/S1873506118300485
_version_ 1818558781052682240
author Ross Ferguson
Vasanta Subramanian
author_facet Ross Ferguson
Vasanta Subramanian
author_sort Ross Ferguson
collection DOAJ
description Three dimensional (3D) culture of mammalian cells is emerging as a powerful new tool to understand organogenesis as well as serve as models for diseases with implications for therapeutic evaluation. 3D cultures are referred to variously as spheroid, organoids or embryoid bodies. While many methods exist for large scale production of embryoid bodies or other spheroid cell aggregates, either at controlled sizes using microwell/micropatterned plates or uncontrolled sizes in suspension dishes, very few protocols exist for medium throughput analysis of differentiation at the histological level. We have developed a method which allows for parallel processing, sectioning and analysis of multiple 3D samples (e.g. fixed at different time points, treated with different drugs/growth factors, generated from different cell lines etc.) by double-embedding blocks in a larger array format. Our protocol has few barriers for use and requires only materials commonly found in any lab currently using embedding materials for cryosectioning. Sectioning in parallel allows histological techniques (such as histochemistry, immunostaining or in situ hybridisation) to be performed simultaneously on many samples on a single slide. This reduces slide to slide variation as well as requiring less reagents, fewer consumables with lower time and labour requirements when compared to individually embedded samples. Keywords: Embryonic stem cells, 3-D cultures, EB arrays, Cryosectioning
first_indexed 2024-12-14T00:16:45Z
format Article
id doaj.art-22b4a4129ad8471eb5b5d493842a8f85
institution Directory Open Access Journal
issn 1873-5061
language English
last_indexed 2024-12-14T00:16:45Z
publishDate 2018-04-01
publisher Elsevier
record_format Article
series Stem Cell Research
spelling doaj.art-22b4a4129ad8471eb5b5d493842a8f852022-12-21T23:25:28ZengElsevierStem Cell Research1873-50612018-04-0128125130Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysisRoss Ferguson0Vasanta Subramanian1Department of Biology and Biochemistry, Building 4 South, University of Bath, Bath BA2 7AY, United Kingdom.Corresponding author.; Department of Biology and Biochemistry, Building 4 South, University of Bath, Bath BA2 7AY, United Kingdom.Three dimensional (3D) culture of mammalian cells is emerging as a powerful new tool to understand organogenesis as well as serve as models for diseases with implications for therapeutic evaluation. 3D cultures are referred to variously as spheroid, organoids or embryoid bodies. While many methods exist for large scale production of embryoid bodies or other spheroid cell aggregates, either at controlled sizes using microwell/micropatterned plates or uncontrolled sizes in suspension dishes, very few protocols exist for medium throughput analysis of differentiation at the histological level. We have developed a method which allows for parallel processing, sectioning and analysis of multiple 3D samples (e.g. fixed at different time points, treated with different drugs/growth factors, generated from different cell lines etc.) by double-embedding blocks in a larger array format. Our protocol has few barriers for use and requires only materials commonly found in any lab currently using embedding materials for cryosectioning. Sectioning in parallel allows histological techniques (such as histochemistry, immunostaining or in situ hybridisation) to be performed simultaneously on many samples on a single slide. This reduces slide to slide variation as well as requiring less reagents, fewer consumables with lower time and labour requirements when compared to individually embedded samples. Keywords: Embryonic stem cells, 3-D cultures, EB arrays, Cryosectioninghttp://www.sciencedirect.com/science/article/pii/S1873506118300485
spellingShingle Ross Ferguson
Vasanta Subramanian
Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysis
Stem Cell Research
title Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysis
title_full Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysis
title_fullStr Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysis
title_full_unstemmed Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysis
title_short Embryoid body arrays: Parallel cryosectioning of spheroid/embryoid body samples for medium through-put analysis
title_sort embryoid body arrays parallel cryosectioning of spheroid embryoid body samples for medium through put analysis
url http://www.sciencedirect.com/science/article/pii/S1873506118300485
work_keys_str_mv AT rossferguson embryoidbodyarraysparallelcryosectioningofspheroidembryoidbodysamplesformediumthroughputanalysis
AT vasantasubramanian embryoidbodyarraysparallelcryosectioningofspheroidembryoidbodysamplesformediumthroughputanalysis