Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator Modules

The intensity of solar energy is an important factor in viewing the performance of the thermoelectric generator (TEG). Most studies only look at the effect of treatment on the TEG module in the form of cooling mode and its materials. Therefore this study examines the effect of the solar intensity va...

Full description

Bibliographic Details
Main Authors: Zuryati Djafar, Abdul Halim, Mustofa Mustofa, Lita Asyriati Latif, Wahyu Haryadi Piarah
Format: Article
Language:English
Published: Khairun University, Faculty of Engineering, Department of Electrical Engineering 2023-09-01
Series:Protek: Jurnal Ilmiah Teknik Elektro
Subjects:
Online Access:https://ejournal.unkhair.ac.id/index.php/protk/article/view/6375
_version_ 1797689398640246784
author Zuryati Djafar
Abdul Halim
Mustofa Mustofa
Lita Asyriati Latif
Wahyu Haryadi Piarah
author_facet Zuryati Djafar
Abdul Halim
Mustofa Mustofa
Lita Asyriati Latif
Wahyu Haryadi Piarah
author_sort Zuryati Djafar
collection DOAJ
description The intensity of solar energy is an important factor in viewing the performance of the thermoelectric generator (TEG). Most studies only look at the effect of treatment on the TEG module in the form of cooling mode and its materials. Therefore this study examines the effect of the solar intensity value on the magnitude of the module voltage. On the hot side of the module are placed heat absorber plates of copper, Fe and aluminum plates as well as non collector plates. Modules are cascaded and connected in series as many as 14 modules per plate, so that a total of 56 TEG modules are used. Data collection is carried out simultaneously on all plates. The test results show that the increase in solar intensity is liner with the magnitude of the TEG module voltage or in other words the correlation is positive. The data also shows that copper collector plates produce the highest voltage difference, followed by Ferro, Alumina and no-plates at ∆V 0.871, 0.805; 0.369 and 0.153 V, respectively
first_indexed 2024-03-12T01:45:10Z
format Article
id doaj.art-2331208113134b46a9ca1c2c99741133
institution Directory Open Access Journal
issn 2354-8924
2527-9572
language English
last_indexed 2024-03-12T01:45:10Z
publishDate 2023-09-01
publisher Khairun University, Faculty of Engineering, Department of Electrical Engineering
record_format Article
series Protek: Jurnal Ilmiah Teknik Elektro
spelling doaj.art-2331208113134b46a9ca1c2c997411332023-09-09T07:31:23ZengKhairun University, Faculty of Engineering, Department of Electrical EngineeringProtek: Jurnal Ilmiah Teknik Elektro2354-89242527-95722023-09-0110317918310.33387/protk.v10i3.63753595Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator ModulesZuryati Djafar0Abdul Halim1Mustofa Mustofa2Lita Asyriati Latif3Wahyu Haryadi Piarah4Universitas HasanuddinUniversitas HasanuddinUniversitas TadulakoUniversitas Khairun TernateUniversitas HasanuddinThe intensity of solar energy is an important factor in viewing the performance of the thermoelectric generator (TEG). Most studies only look at the effect of treatment on the TEG module in the form of cooling mode and its materials. Therefore this study examines the effect of the solar intensity value on the magnitude of the module voltage. On the hot side of the module are placed heat absorber plates of copper, Fe and aluminum plates as well as non collector plates. Modules are cascaded and connected in series as many as 14 modules per plate, so that a total of 56 TEG modules are used. Data collection is carried out simultaneously on all plates. The test results show that the increase in solar intensity is liner with the magnitude of the TEG module voltage or in other words the correlation is positive. The data also shows that copper collector plates produce the highest voltage difference, followed by Ferro, Alumina and no-plates at ∆V 0.871, 0.805; 0.369 and 0.153 V, respectivelyhttps://ejournal.unkhair.ac.id/index.php/protk/article/view/6375sun intensityvoltagepower outputthermal absorber
spellingShingle Zuryati Djafar
Abdul Halim
Mustofa Mustofa
Lita Asyriati Latif
Wahyu Haryadi Piarah
Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator Modules
Protek: Jurnal Ilmiah Teknik Elektro
sun intensity
voltage
power output
thermal absorber
title Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator Modules
title_full Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator Modules
title_fullStr Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator Modules
title_full_unstemmed Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator Modules
title_short Correlation of Sunlight Intensity and Output Voltage on Collector Plate-based Cascaded Thermoelectric Generator Modules
title_sort correlation of sunlight intensity and output voltage on collector plate based cascaded thermoelectric generator modules
topic sun intensity
voltage
power output
thermal absorber
url https://ejournal.unkhair.ac.id/index.php/protk/article/view/6375
work_keys_str_mv AT zuryatidjafar correlationofsunlightintensityandoutputvoltageoncollectorplatebasedcascadedthermoelectricgeneratormodules
AT abdulhalim correlationofsunlightintensityandoutputvoltageoncollectorplatebasedcascadedthermoelectricgeneratormodules
AT mustofamustofa correlationofsunlightintensityandoutputvoltageoncollectorplatebasedcascadedthermoelectricgeneratormodules
AT litaasyriatilatif correlationofsunlightintensityandoutputvoltageoncollectorplatebasedcascadedthermoelectricgeneratormodules
AT wahyuharyadipiarah correlationofsunlightintensityandoutputvoltageoncollectorplatebasedcascadedthermoelectricgeneratormodules