Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinoma

Objective This study aimed to identify the effects of beamlet width on dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) and determine the optimal parameters for the most effective radiotherapy plan. Methods This study evaluated 20 patients with NPC were selecte...

Full description

Bibliographic Details
Main Authors: Manya Wu, Jinhui Jin, Zhenghuan Li, Fantu Kong, Yadi He, Lijiang Liu, Wei Yang, Xiangying Xu
Format: Article
Language:English
Published: PeerJ Inc. 2022-08-01
Series:PeerJ
Subjects:
Online Access:https://peerj.com/articles/13748.pdf
_version_ 1827608299145527296
author Manya Wu
Jinhui Jin
Zhenghuan Li
Fantu Kong
Yadi He
Lijiang Liu
Wei Yang
Xiangying Xu
author_facet Manya Wu
Jinhui Jin
Zhenghuan Li
Fantu Kong
Yadi He
Lijiang Liu
Wei Yang
Xiangying Xu
author_sort Manya Wu
collection DOAJ
description Objective This study aimed to identify the effects of beamlet width on dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) and determine the optimal parameters for the most effective radiotherapy plan. Methods This study evaluated 20 patients with NPC were selected for dynamic IMRT. Only the beamlet width in the optimization parameters was changed (set to 2, 4, 6, 8, and 10 mm that were named BL02, BL04, BL06, BL08, and BL10, respectively) to optimize the results of the five groups of plans. Using the plan quality scoring system, the dose results of the planning target volumes (PTVs) and organs at risks (OARs) were analyzed objectively and comprehensively. The lower the quality score, the better the quality of the plan. The efficiency and accuracy of plan execution were evaluated using monitor units (MUs) and plan delivery time (PDT). Results The BL04 mm group had the lowest quality score for the targets and OARs (0.087), while the BL10 mm group had the highest total score (1.249). The BL04 mm group had the highest MUs (837 MUs) and longest PDT (358 s). However, the MUs range of each group plan was below 100 MUs, and the PDT range was within 30 s. In the BL02, BL04, BL06, BL08, and BL10 plans, <5 MUs segments accounted for 33%, 16%, 24%, 33%, and 40% of total segments, respectively, with which the lowest was in the BL04 mm group. Conclusion Smaller beamlet widths have not only reduced OARs dose while maintaining high dose coverage to the PTVs, but also lead to more MUs that would produce greater PDT. Considering the quality and efficiency of dynamic IMRT, the beamlet width value of the Monaco treatment planning system set to 4 mm would be optimal for NPC.
first_indexed 2024-03-09T07:11:05Z
format Article
id doaj.art-2363010fd0d5472e82ceedd5b8ac8465
institution Directory Open Access Journal
issn 2167-8359
language English
last_indexed 2024-03-09T07:11:05Z
publishDate 2022-08-01
publisher PeerJ Inc.
record_format Article
series PeerJ
spelling doaj.art-2363010fd0d5472e82ceedd5b8ac84652023-12-03T09:07:14ZengPeerJ Inc.PeerJ2167-83592022-08-0110e1374810.7717/peerj.13748Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinomaManya Wu0Jinhui Jin1Zhenghuan Li2Fantu Kong3Yadi He4Lijiang Liu5Wei Yang6Xiangying Xu7Department of Radiation Oncology, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, ChinaSchool of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, ChinaDepartment of Radiation Oncology, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, ChinaDepartment of Radiation Oncology, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, ChinaSchool of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, ChinaSchool of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, ChinaSchool of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, ChinaDepartment of Radiation Oncology, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, Guangdong, ChinaObjective This study aimed to identify the effects of beamlet width on dynamic intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) and determine the optimal parameters for the most effective radiotherapy plan. Methods This study evaluated 20 patients with NPC were selected for dynamic IMRT. Only the beamlet width in the optimization parameters was changed (set to 2, 4, 6, 8, and 10 mm that were named BL02, BL04, BL06, BL08, and BL10, respectively) to optimize the results of the five groups of plans. Using the plan quality scoring system, the dose results of the planning target volumes (PTVs) and organs at risks (OARs) were analyzed objectively and comprehensively. The lower the quality score, the better the quality of the plan. The efficiency and accuracy of plan execution were evaluated using monitor units (MUs) and plan delivery time (PDT). Results The BL04 mm group had the lowest quality score for the targets and OARs (0.087), while the BL10 mm group had the highest total score (1.249). The BL04 mm group had the highest MUs (837 MUs) and longest PDT (358 s). However, the MUs range of each group plan was below 100 MUs, and the PDT range was within 30 s. In the BL02, BL04, BL06, BL08, and BL10 plans, <5 MUs segments accounted for 33%, 16%, 24%, 33%, and 40% of total segments, respectively, with which the lowest was in the BL04 mm group. Conclusion Smaller beamlet widths have not only reduced OARs dose while maintaining high dose coverage to the PTVs, but also lead to more MUs that would produce greater PDT. Considering the quality and efficiency of dynamic IMRT, the beamlet width value of the Monaco treatment planning system set to 4 mm would be optimal for NPC.https://peerj.com/articles/13748.pdfIMRTBeamlet widthPlan qualityDelivery efficiencyNPC
spellingShingle Manya Wu
Jinhui Jin
Zhenghuan Li
Fantu Kong
Yadi He
Lijiang Liu
Wei Yang
Xiangying Xu
Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinoma
PeerJ
IMRT
Beamlet width
Plan quality
Delivery efficiency
NPC
title Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinoma
title_full Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinoma
title_fullStr Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinoma
title_full_unstemmed Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinoma
title_short Influence of beamlet width on dynamic IMRT plan quality in nasopharyngeal carcinoma
title_sort influence of beamlet width on dynamic imrt plan quality in nasopharyngeal carcinoma
topic IMRT
Beamlet width
Plan quality
Delivery efficiency
NPC
url https://peerj.com/articles/13748.pdf
work_keys_str_mv AT manyawu influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma
AT jinhuijin influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma
AT zhenghuanli influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma
AT fantukong influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma
AT yadihe influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma
AT lijiangliu influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma
AT weiyang influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma
AT xiangyingxu influenceofbeamletwidthondynamicimrtplanqualityinnasopharyngealcarcinoma