Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.

Tissue perfusion during surgery is important in reducing surgical site infections and promoting healing. This study aimed to determine if insufflation of the open abdomen with heated, humidified (HH) carbon dioxide (CO2) increased visceral tissue perfusion and core body temperature during open abdom...

Full description

Bibliographic Details
Main Authors: Jonathan P Robson, Pavlo Kokhanenko, Jean K Marshall, Anthony R Phillips, Jan van der Linden
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5884566?pdf=render
_version_ 1818922856451407872
author Jonathan P Robson
Pavlo Kokhanenko
Jean K Marshall
Anthony R Phillips
Jan van der Linden
author_facet Jonathan P Robson
Pavlo Kokhanenko
Jean K Marshall
Anthony R Phillips
Jan van der Linden
author_sort Jonathan P Robson
collection DOAJ
description Tissue perfusion during surgery is important in reducing surgical site infections and promoting healing. This study aimed to determine if insufflation of the open abdomen with heated, humidified (HH) carbon dioxide (CO2) increased visceral tissue perfusion and core body temperature during open abdominal surgery in a rodent model. Using two different rodent models of open abdominal surgery, visceral perfusion and core temperature were measured. Visceral perfusion was investigated using a repeated measures crossover experiment with rodents receiving the same sequence of two alternating treatments: exposure to ambient air (no insufflation) and insufflation with HH CO2. Core body temperature was measured using an independent experimental design with three treatment groups: ambient air, HH CO2 and cold, dry (CD) CO2. Visceral perfusion was measured by laser speckle contrast analysis (LASCA) and core body temperature was measured with a rectal thermometer. Insufflation with HH CO2 into a rodent open abdominal cavity significantly increased visceral tissue perfusion (2.4 perfusion units (PU)/min (95% CI 1.23-3.58); p<0.0001) compared with ambient air, which significantly reduced visceral blood flow (-5.20 PU/min (95% CI -6.83- -3.58); p<0.0001). Insufflation of HH CO2 into the open abdominal cavity significantly increased core body temperature (+1.15 ± 0.14°C) compared with open cavities exposed to ambient air (-0.65 ± 0.52°C; p = 0.037), or cavities insufflated with CD CO2 (-0.73 ± 0.33°C; p = 0.006). Abdominal visceral temperatures also increased with HH CO2 insufflation compared with ambient air or CD CO2, as shown by infrared thermography. This study reports for the first time the use of LASCA to measure visceral perfusion in open abdominal surgery and shows that insufflation of open abdominal cavities with HH CO2 significantly increases visceral tissue perfusion and core body temperature.
first_indexed 2024-12-20T02:00:11Z
format Article
id doaj.art-236abe5206d540f2a66e645ad96256f4
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-20T02:00:11Z
publishDate 2018-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-236abe5206d540f2a66e645ad96256f42022-12-21T19:57:20ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-01134e019546510.1371/journal.pone.0195465Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.Jonathan P RobsonPavlo KokhanenkoJean K MarshallAnthony R PhillipsJan van der LindenTissue perfusion during surgery is important in reducing surgical site infections and promoting healing. This study aimed to determine if insufflation of the open abdomen with heated, humidified (HH) carbon dioxide (CO2) increased visceral tissue perfusion and core body temperature during open abdominal surgery in a rodent model. Using two different rodent models of open abdominal surgery, visceral perfusion and core temperature were measured. Visceral perfusion was investigated using a repeated measures crossover experiment with rodents receiving the same sequence of two alternating treatments: exposure to ambient air (no insufflation) and insufflation with HH CO2. Core body temperature was measured using an independent experimental design with three treatment groups: ambient air, HH CO2 and cold, dry (CD) CO2. Visceral perfusion was measured by laser speckle contrast analysis (LASCA) and core body temperature was measured with a rectal thermometer. Insufflation with HH CO2 into a rodent open abdominal cavity significantly increased visceral tissue perfusion (2.4 perfusion units (PU)/min (95% CI 1.23-3.58); p<0.0001) compared with ambient air, which significantly reduced visceral blood flow (-5.20 PU/min (95% CI -6.83- -3.58); p<0.0001). Insufflation of HH CO2 into the open abdominal cavity significantly increased core body temperature (+1.15 ± 0.14°C) compared with open cavities exposed to ambient air (-0.65 ± 0.52°C; p = 0.037), or cavities insufflated with CD CO2 (-0.73 ± 0.33°C; p = 0.006). Abdominal visceral temperatures also increased with HH CO2 insufflation compared with ambient air or CD CO2, as shown by infrared thermography. This study reports for the first time the use of LASCA to measure visceral perfusion in open abdominal surgery and shows that insufflation of open abdominal cavities with HH CO2 significantly increases visceral tissue perfusion and core body temperature.http://europepmc.org/articles/PMC5884566?pdf=render
spellingShingle Jonathan P Robson
Pavlo Kokhanenko
Jean K Marshall
Anthony R Phillips
Jan van der Linden
Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.
PLoS ONE
title Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.
title_full Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.
title_fullStr Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.
title_full_unstemmed Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.
title_short Increased visceral tissue perfusion with heated, humidified carbon dioxide insufflation during open abdominal surgery in a rodent model.
title_sort increased visceral tissue perfusion with heated humidified carbon dioxide insufflation during open abdominal surgery in a rodent model
url http://europepmc.org/articles/PMC5884566?pdf=render
work_keys_str_mv AT jonathanprobson increasedvisceraltissueperfusionwithheatedhumidifiedcarbondioxideinsufflationduringopenabdominalsurgeryinarodentmodel
AT pavlokokhanenko increasedvisceraltissueperfusionwithheatedhumidifiedcarbondioxideinsufflationduringopenabdominalsurgeryinarodentmodel
AT jeankmarshall increasedvisceraltissueperfusionwithheatedhumidifiedcarbondioxideinsufflationduringopenabdominalsurgeryinarodentmodel
AT anthonyrphillips increasedvisceraltissueperfusionwithheatedhumidifiedcarbondioxideinsufflationduringopenabdominalsurgeryinarodentmodel
AT janvanderlinden increasedvisceraltissueperfusionwithheatedhumidifiedcarbondioxideinsufflationduringopenabdominalsurgeryinarodentmodel