Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
O objetivo deste trabalho foi calibrar o medidor de clorofila Minolta SPAD-502 para avaliação da nutrição nitrogenada das plantas de milho, baseando-se na prévia comparação das leituras de clorofila com os teores obtidos pelos extratores N,N-dimetilformamida (DMF) e acetona 80%. No campo, foram aval...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Embrapa Informação Tecnológica
2003-09-01
|
Series: | Pesquisa Agropecuária Brasileira |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-204X2003000900014 |
_version_ | 1818248104384659456 |
---|---|
author | Lincoln Zotarelli Eduardo Garcia Cardoso Jorge Luiz Piccinin Segundo Urquiaga Robert Michael Boddey Eleno Torres Bruno José Rodrigues Alves |
author_facet | Lincoln Zotarelli Eduardo Garcia Cardoso Jorge Luiz Piccinin Segundo Urquiaga Robert Michael Boddey Eleno Torres Bruno José Rodrigues Alves |
author_sort | Lincoln Zotarelli |
collection | DOAJ |
description | O objetivo deste trabalho foi calibrar o medidor de clorofila Minolta SPAD-502 para avaliação da nutrição nitrogenada das plantas de milho, baseando-se na prévia comparação das leituras de clorofila com os teores obtidos pelos extratores N,N-dimetilformamida (DMF) e acetona 80%. No campo, foram avaliados os teores de clorofila em folhas de milho cultivado sob plantio direto após a cultura de aveia-preta e após a de tremoço-branco, por duas safras consecutivas. A extração da clorofila com a solução DMF, por 72 horas, foi a mais indicada para a calibração do medidor de clorofila SPAD502 na cultura do milho. O ajuste do modelo linear expressou melhor a relação entre o conteúdo de clorofila e as leituras do SPAD na cultura do milho, e seu uso produziu resultados coerentes com o estado nutricional da cultura.<br>The subject of this study was the calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the N nutrition of maize, firstly comparing the chlorophyll readings to the contents obtained from either 80% acetone or N,N-dimethylformamide (DMF) chlorophyll extrators. The chlorophyll of the maize leaves cultivated under zerotillage after oat and lupin for two consecutive harvests was evaluated in a field experiment. The chlorophyll extraction after 72 hours in DMF solution, was the most suitable for the calibration of the SPAD502 chlorophyll meter for maize and its use was coherent with the nutritional status of the crop. |
first_indexed | 2024-12-12T15:15:17Z |
format | Article |
id | doaj.art-23b614b6bbc44ca3ba599b44bae3e175 |
institution | Directory Open Access Journal |
issn | 0100-204X 1678-3921 |
language | English |
last_indexed | 2024-12-12T15:15:17Z |
publishDate | 2003-09-01 |
publisher | Embrapa Informação Tecnológica |
record_format | Article |
series | Pesquisa Agropecuária Brasileira |
spelling | doaj.art-23b614b6bbc44ca3ba599b44bae3e1752022-12-22T00:20:31ZengEmbrapa Informação TecnológicaPesquisa Agropecuária Brasileira0100-204X1678-39212003-09-013891117112210.1590/S0100-204X2003000900014Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maizeLincoln ZotarelliEduardo Garcia CardosoJorge Luiz PiccininSegundo UrquiagaRobert Michael BoddeyEleno TorresBruno José Rodrigues AlvesO objetivo deste trabalho foi calibrar o medidor de clorofila Minolta SPAD-502 para avaliação da nutrição nitrogenada das plantas de milho, baseando-se na prévia comparação das leituras de clorofila com os teores obtidos pelos extratores N,N-dimetilformamida (DMF) e acetona 80%. No campo, foram avaliados os teores de clorofila em folhas de milho cultivado sob plantio direto após a cultura de aveia-preta e após a de tremoço-branco, por duas safras consecutivas. A extração da clorofila com a solução DMF, por 72 horas, foi a mais indicada para a calibração do medidor de clorofila SPAD502 na cultura do milho. O ajuste do modelo linear expressou melhor a relação entre o conteúdo de clorofila e as leituras do SPAD na cultura do milho, e seu uso produziu resultados coerentes com o estado nutricional da cultura.<br>The subject of this study was the calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the N nutrition of maize, firstly comparing the chlorophyll readings to the contents obtained from either 80% acetone or N,N-dimethylformamide (DMF) chlorophyll extrators. The chlorophyll of the maize leaves cultivated under zerotillage after oat and lupin for two consecutive harvests was evaluated in a field experiment. The chlorophyll extraction after 72 hours in DMF solution, was the most suitable for the calibration of the SPAD502 chlorophyll meter for maize and its use was coherent with the nutritional status of the crop.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-204X2003000900014Avena strigosaLupinus albusadubo verdeestado nutricionalAvena strigosaLupinus albusgreen manuresnutritional status |
spellingShingle | Lincoln Zotarelli Eduardo Garcia Cardoso Jorge Luiz Piccinin Segundo Urquiaga Robert Michael Boddey Eleno Torres Bruno José Rodrigues Alves Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize Pesquisa Agropecuária Brasileira Avena strigosa Lupinus albus adubo verde estado nutricional Avena strigosa Lupinus albus green manures nutritional status |
title | Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize |
title_full | Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize |
title_fullStr | Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize |
title_full_unstemmed | Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize |
title_short | Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize |
title_sort | calibracao do medidor de clorofila minolta spad 502 para avaliacao do conteudo de nitrogenio do milho calibration of a minolta spad 502 chlorophyll meter for evaluation of the nitrogen nutrition of maize |
topic | Avena strigosa Lupinus albus adubo verde estado nutricional Avena strigosa Lupinus albus green manures nutritional status |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-204X2003000900014 |
work_keys_str_mv | AT lincolnzotarelli calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize AT eduardogarciacardoso calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize AT jorgeluizpiccinin calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize AT segundourquiaga calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize AT robertmichaelboddey calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize AT elenotorres calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize AT brunojoserodriguesalves calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize |