Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize

O objetivo deste trabalho foi calibrar o medidor de clorofila Minolta SPAD-502 para avaliação da nutrição nitrogenada das plantas de milho, baseando-se na prévia comparação das leituras de clorofila com os teores obtidos pelos extratores N,N-dimetilformamida (DMF) e acetona 80%. No campo, foram aval...

Full description

Bibliographic Details
Main Authors: Lincoln Zotarelli, Eduardo Garcia Cardoso, Jorge Luiz Piccinin, Segundo Urquiaga, Robert Michael Boddey, Eleno Torres, Bruno José Rodrigues Alves
Format: Article
Language:English
Published: Embrapa Informação Tecnológica 2003-09-01
Series:Pesquisa Agropecuária Brasileira
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-204X2003000900014
_version_ 1818248104384659456
author Lincoln Zotarelli
Eduardo Garcia Cardoso
Jorge Luiz Piccinin
Segundo Urquiaga
Robert Michael Boddey
Eleno Torres
Bruno José Rodrigues Alves
author_facet Lincoln Zotarelli
Eduardo Garcia Cardoso
Jorge Luiz Piccinin
Segundo Urquiaga
Robert Michael Boddey
Eleno Torres
Bruno José Rodrigues Alves
author_sort Lincoln Zotarelli
collection DOAJ
description O objetivo deste trabalho foi calibrar o medidor de clorofila Minolta SPAD-502 para avaliação da nutrição nitrogenada das plantas de milho, baseando-se na prévia comparação das leituras de clorofila com os teores obtidos pelos extratores N,N-dimetilformamida (DMF) e acetona 80%. No campo, foram avaliados os teores de clorofila em folhas de milho cultivado sob plantio direto após a cultura de aveia-preta e após a de tremoço-branco, por duas safras consecutivas. A extração da clorofila com a solução DMF, por 72 horas, foi a mais indicada para a calibração do medidor de clorofila SPAD502 na cultura do milho. O ajuste do modelo linear expressou melhor a relação entre o conteúdo de clorofila e as leituras do SPAD na cultura do milho, e seu uso produziu resultados coerentes com o estado nutricional da cultura.<br>The subject of this study was the calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the N nutrition of maize, firstly comparing the chlorophyll readings to the contents obtained from either 80% acetone or N,N-dimethylformamide (DMF) chlorophyll extrators. The chlorophyll of the maize leaves cultivated under zerotillage after oat and lupin for two consecutive harvests was evaluated in a field experiment. The chlorophyll extraction after 72 hours in DMF solution, was the most suitable for the calibration of the SPAD502 chlorophyll meter for maize and its use was coherent with the nutritional status of the crop.
first_indexed 2024-12-12T15:15:17Z
format Article
id doaj.art-23b614b6bbc44ca3ba599b44bae3e175
institution Directory Open Access Journal
issn 0100-204X
1678-3921
language English
last_indexed 2024-12-12T15:15:17Z
publishDate 2003-09-01
publisher Embrapa Informação Tecnológica
record_format Article
series Pesquisa Agropecuária Brasileira
spelling doaj.art-23b614b6bbc44ca3ba599b44bae3e1752022-12-22T00:20:31ZengEmbrapa Informação TecnológicaPesquisa Agropecuária Brasileira0100-204X1678-39212003-09-013891117112210.1590/S0100-204X2003000900014Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maizeLincoln ZotarelliEduardo Garcia CardosoJorge Luiz PiccininSegundo UrquiagaRobert Michael BoddeyEleno TorresBruno José Rodrigues AlvesO objetivo deste trabalho foi calibrar o medidor de clorofila Minolta SPAD-502 para avaliação da nutrição nitrogenada das plantas de milho, baseando-se na prévia comparação das leituras de clorofila com os teores obtidos pelos extratores N,N-dimetilformamida (DMF) e acetona 80%. No campo, foram avaliados os teores de clorofila em folhas de milho cultivado sob plantio direto após a cultura de aveia-preta e após a de tremoço-branco, por duas safras consecutivas. A extração da clorofila com a solução DMF, por 72 horas, foi a mais indicada para a calibração do medidor de clorofila SPAD502 na cultura do milho. O ajuste do modelo linear expressou melhor a relação entre o conteúdo de clorofila e as leituras do SPAD na cultura do milho, e seu uso produziu resultados coerentes com o estado nutricional da cultura.<br>The subject of this study was the calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the N nutrition of maize, firstly comparing the chlorophyll readings to the contents obtained from either 80% acetone or N,N-dimethylformamide (DMF) chlorophyll extrators. The chlorophyll of the maize leaves cultivated under zerotillage after oat and lupin for two consecutive harvests was evaluated in a field experiment. The chlorophyll extraction after 72 hours in DMF solution, was the most suitable for the calibration of the SPAD502 chlorophyll meter for maize and its use was coherent with the nutritional status of the crop.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-204X2003000900014Avena strigosaLupinus albusadubo verdeestado nutricionalAvena strigosaLupinus albusgreen manuresnutritional status
spellingShingle Lincoln Zotarelli
Eduardo Garcia Cardoso
Jorge Luiz Piccinin
Segundo Urquiaga
Robert Michael Boddey
Eleno Torres
Bruno José Rodrigues Alves
Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
Pesquisa Agropecuária Brasileira
Avena strigosa
Lupinus albus
adubo verde
estado nutricional
Avena strigosa
Lupinus albus
green manures
nutritional status
title Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
title_full Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
title_fullStr Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
title_full_unstemmed Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
title_short Calibração do medidor de clorofila Minolta SPAD-502 para avaliação do conteúdo de nitrogênio do milho Calibration of a Minolta SPAD-502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
title_sort calibracao do medidor de clorofila minolta spad 502 para avaliacao do conteudo de nitrogenio do milho calibration of a minolta spad 502 chlorophyll meter for evaluation of the nitrogen nutrition of maize
topic Avena strigosa
Lupinus albus
adubo verde
estado nutricional
Avena strigosa
Lupinus albus
green manures
nutritional status
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-204X2003000900014
work_keys_str_mv AT lincolnzotarelli calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize
AT eduardogarciacardoso calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize
AT jorgeluizpiccinin calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize
AT segundourquiaga calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize
AT robertmichaelboddey calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize
AT elenotorres calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize
AT brunojoserodriguesalves calibracaodomedidordeclorofilaminoltaspad502paraavaliacaodoconteudodenitrogeniodomilhocalibrationofaminoltaspad502chlorophyllmeterforevaluationofthenitrogennutritionofmaize