Maximum phonation time in the pulmonary function assessment
ABSTRACT Purpose: to evaluate the reliability of the maximum phonation time (MPT) and Vital Capacity intra and inter-examiner, by means of the single-breath counting test (CT) and the sustained /a/ phoneme, and the slow vital capacity (SVC). Methods: a reliability study carried out in three groups...
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Associação Brasileira de Motricidade Orofacial - ABRAMO
2021-05-01
|
Series: | Revista CEFAC |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-18462021000400502&tlng=pt |
_version_ | 1827165967238561792 |
---|---|
author | Edvania Gomes Henrique Moreno Bianca Teixeira Calassa Daniela Vitoria Silva Oliveira Maylanne Iris Nascimento Silva Laienne Carla Barbosa de Barros Albuquerque Ricardo de Freitas-Dias Bruno Rafael Vieira Souza Silva Rodrigo Capatto de Araújo Eduarda Lubambo Costa Emília Chagas Costa Marco Aurélio de Valois Correia Junior |
author_facet | Edvania Gomes Henrique Moreno Bianca Teixeira Calassa Daniela Vitoria Silva Oliveira Maylanne Iris Nascimento Silva Laienne Carla Barbosa de Barros Albuquerque Ricardo de Freitas-Dias Bruno Rafael Vieira Souza Silva Rodrigo Capatto de Araújo Eduarda Lubambo Costa Emília Chagas Costa Marco Aurélio de Valois Correia Junior |
author_sort | Edvania Gomes Henrique Moreno |
collection | DOAJ |
description | ABSTRACT Purpose: to evaluate the reliability of the maximum phonation time (MPT) and Vital Capacity intra and inter-examiner, by means of the single-breath counting test (CT) and the sustained /a/ phoneme, and the slow vital capacity (SVC). Methods: a reliability study carried out in three groups of healthy individuals, each group with 30 volunteers, allocated according to age. SVC was measured using a spirometer, while the MPT was assessed by the phoneme /a/ and CT. The data were analyzed using SPSS version 20.0. Initially, descriptive statistics were used and for data reliability, the intraclass correlation coefficient (ICC). Results: the Intraclass Correlation Coefficients (ICC) were considered excellent, with significant results above 0.92 for SVC and greater than 0.79 for CT and phoneme /a/. Regarding the inter-examiner evaluation, the ICCs were also significant for both SVC with values greater than 0.96, and for CT and the phoneme /a/ with values greater than 0.85. The error inherent in the technique was assessed using the standard error of the measurement for intra and inter-examiner analyses with values ranging from 1.79 to 3.29 for phoneme /a/, 3.20 to 6.58 for CT and 65, 05 to 206.73 for SVCml. Conclusion: phonation techniques with the phoneme /a/ and CT, as well as SVC, have an excellent reliability, due to intra and inter-examiner agreement measures. |
first_indexed | 2024-04-11T18:29:32Z |
format | Article |
id | doaj.art-23bf44be1e1848b28717ee99bf34c94f |
institution | Directory Open Access Journal |
issn | 1982-0216 |
language | English |
last_indexed | 2025-03-21T01:40:54Z |
publishDate | 2021-05-01 |
publisher | Associação Brasileira de Motricidade Orofacial - ABRAMO |
record_format | Article |
series | Revista CEFAC |
spelling | doaj.art-23bf44be1e1848b28717ee99bf34c94f2024-08-02T23:39:03ZengAssociação Brasileira de Motricidade Orofacial - ABRAMORevista CEFAC1982-02162021-05-0123410.1590/1982-0216/20212349720Maximum phonation time in the pulmonary function assessmentEdvania Gomes Henrique Morenohttps://orcid.org/0000-0002-8195-4468Bianca Teixeira Calassahttps://orcid.org/0000-0003-0779-6585Daniela Vitoria Silva Oliveirahttps://orcid.org/0000-0002-0702-6663Maylanne Iris Nascimento Silvahttps://orcid.org/0000-0002-5991-9287Laienne Carla Barbosa de Barros Albuquerquehttps://orcid.org/0000-0001-6612-5269Ricardo de Freitas-Diashttps://orcid.org/0000-0003-4846-9951Bruno Rafael Vieira Souza Silvahttps://orcid.org/0000-0002-6140-6990Rodrigo Capatto de Araújohttps://orcid.org/0000-0002-6399-3201Eduarda Lubambo Costahttps://orcid.org/0000-0001-9549-4426Emília Chagas Costahttps://orcid.org/0000-0002-7664-5994Marco Aurélio de Valois Correia Juniorhttps://orcid.org/0000-0003-0386-5256ABSTRACT Purpose: to evaluate the reliability of the maximum phonation time (MPT) and Vital Capacity intra and inter-examiner, by means of the single-breath counting test (CT) and the sustained /a/ phoneme, and the slow vital capacity (SVC). Methods: a reliability study carried out in three groups of healthy individuals, each group with 30 volunteers, allocated according to age. SVC was measured using a spirometer, while the MPT was assessed by the phoneme /a/ and CT. The data were analyzed using SPSS version 20.0. Initially, descriptive statistics were used and for data reliability, the intraclass correlation coefficient (ICC). Results: the Intraclass Correlation Coefficients (ICC) were considered excellent, with significant results above 0.92 for SVC and greater than 0.79 for CT and phoneme /a/. Regarding the inter-examiner evaluation, the ICCs were also significant for both SVC with values greater than 0.96, and for CT and the phoneme /a/ with values greater than 0.85. The error inherent in the technique was assessed using the standard error of the measurement for intra and inter-examiner analyses with values ranging from 1.79 to 3.29 for phoneme /a/, 3.20 to 6.58 for CT and 65, 05 to 206.73 for SVCml. Conclusion: phonation techniques with the phoneme /a/ and CT, as well as SVC, have an excellent reliability, due to intra and inter-examiner agreement measures.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-18462021000400502&tlng=ptPhonationVital CapacitySpirometryHealth Assessment |
spellingShingle | Edvania Gomes Henrique Moreno Bianca Teixeira Calassa Daniela Vitoria Silva Oliveira Maylanne Iris Nascimento Silva Laienne Carla Barbosa de Barros Albuquerque Ricardo de Freitas-Dias Bruno Rafael Vieira Souza Silva Rodrigo Capatto de Araújo Eduarda Lubambo Costa Emília Chagas Costa Marco Aurélio de Valois Correia Junior Maximum phonation time in the pulmonary function assessment Revista CEFAC Phonation Vital Capacity Spirometry Health Assessment |
title | Maximum phonation time in the pulmonary function assessment |
title_full | Maximum phonation time in the pulmonary function assessment |
title_fullStr | Maximum phonation time in the pulmonary function assessment |
title_full_unstemmed | Maximum phonation time in the pulmonary function assessment |
title_short | Maximum phonation time in the pulmonary function assessment |
title_sort | maximum phonation time in the pulmonary function assessment |
topic | Phonation Vital Capacity Spirometry Health Assessment |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-18462021000400502&tlng=pt |
work_keys_str_mv | AT edvaniagomeshenriquemoreno maximumphonationtimeinthepulmonaryfunctionassessment AT biancateixeiracalassa maximumphonationtimeinthepulmonaryfunctionassessment AT danielavitoriasilvaoliveira maximumphonationtimeinthepulmonaryfunctionassessment AT maylanneirisnascimentosilva maximumphonationtimeinthepulmonaryfunctionassessment AT laiennecarlabarbosadebarrosalbuquerque maximumphonationtimeinthepulmonaryfunctionassessment AT ricardodefreitasdias maximumphonationtimeinthepulmonaryfunctionassessment AT brunorafaelvieirasouzasilva maximumphonationtimeinthepulmonaryfunctionassessment AT rodrigocapattodearaujo maximumphonationtimeinthepulmonaryfunctionassessment AT eduardalubambocosta maximumphonationtimeinthepulmonaryfunctionassessment AT emiliachagascosta maximumphonationtimeinthepulmonaryfunctionassessment AT marcoaureliodevaloiscorreiajunior maximumphonationtimeinthepulmonaryfunctionassessment |