Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument

In order to further play role of coal mine safety monitoring system in gas control, AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument should be amended. The main contents of proposed amendments include: adding wind direction sensor and dust sensor...

Full description

Bibliographic Details
Main Author: SUN Jiping
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2016-03-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2016.03.001
_version_ 1797868827420131328
author SUN Jiping
author_facet SUN Jiping
author_sort SUN Jiping
collection DOAJ
description In order to further play role of coal mine safety monitoring system in gas control, AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument should be amended. The main contents of proposed amendments include: adding wind direction sensor and dust sensor; mine directors in underground should carry wireless portable methane alarm detector or wireless digital methane detect and alarm head lamp with wireless transmission function; protection grade of sensor should be not less than IP65; coal and gas outburst mines should use full range or high and low concentration methane sensor; coal mine safety monitoring system should be networked, and upload real-time monitoring data to superior; the system can transmit information by cable or optical cable; backbone cable should be divided from different shaft or from different positions with some distance in a shaft into underground; safety monitoring system cannot share the same optical fiber with image monitoring system; safety monitoring equipment should be regularly adjusted and tested 1 time per month at least; adjustment period of carrier catalytic methane sensor, wireless portable methane alarm detector and wireless methane detect and alarm head lamp should be increased from 10 days to 15 days, and the sensor should be adjusted in setting location; methane electric blocking and wind power blocking function should be tested at least 1 time per 15 days, and equipment that may cause local ventilator power outage should be tested 1 time per 6 months; dual host computer hot-backup is needed, and switch time from the host to the backup host should be not more than 40 s; scheduling staff on duty should power off and order related personnel to evacuate after receiving alarm, power outage and abnormal feed information.
first_indexed 2024-04-10T00:01:59Z
format Article
id doaj.art-23d63cda9797495285a59178c197cebe
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-10T00:01:59Z
publishDate 2016-03-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-23d63cda9797495285a59178c197cebe2023-03-17T01:42:26ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2016-03-014231610.13272/j.issn.1671-251x.2016.03.001Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing InstrumentSUN JipingIn order to further play role of coal mine safety monitoring system in gas control, AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument should be amended. The main contents of proposed amendments include: adding wind direction sensor and dust sensor; mine directors in underground should carry wireless portable methane alarm detector or wireless digital methane detect and alarm head lamp with wireless transmission function; protection grade of sensor should be not less than IP65; coal and gas outburst mines should use full range or high and low concentration methane sensor; coal mine safety monitoring system should be networked, and upload real-time monitoring data to superior; the system can transmit information by cable or optical cable; backbone cable should be divided from different shaft or from different positions with some distance in a shaft into underground; safety monitoring system cannot share the same optical fiber with image monitoring system; safety monitoring equipment should be regularly adjusted and tested 1 time per month at least; adjustment period of carrier catalytic methane sensor, wireless portable methane alarm detector and wireless methane detect and alarm head lamp should be increased from 10 days to 15 days, and the sensor should be adjusted in setting location; methane electric blocking and wind power blocking function should be tested at least 1 time per 15 days, and equipment that may cause local ventilator power outage should be tested 1 time per 6 months; dual host computer hot-backup is needed, and switch time from the host to the backup host should be not more than 40 s; scheduling staff on duty should power off and order related personnel to evacuate after receiving alarm, power outage and abnormal feed information.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2016.03.001coal mine safety monitoring systemcoal and gas outburstnetworkingmethane sensorwind direction sensorwireless transmissio
spellingShingle SUN Jiping
Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument
Gong-kuang zidonghua
coal mine safety monitoring system
coal and gas outburst
networking
methane sensor
wind direction sensor
wireless transmissio
title Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument
title_full Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument
title_fullStr Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument
title_full_unstemmed Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument
title_short Revision amendments of AQ 1029-2007 Use Management Specification of Coal Mine Safety Monitoring System and Testing Instrument
title_sort revision amendments of aq 1029 2007 use management specification of coal mine safety monitoring system and testing instrument
topic coal mine safety monitoring system
coal and gas outburst
networking
methane sensor
wind direction sensor
wireless transmissio
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2016.03.001
work_keys_str_mv AT sunjiping revisionamendmentsofaq10292007usemanagementspecificationofcoalminesafetymonitoringsystemandtestinginstrument