Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation

Abstract Background Changes in coagulability during the hyperacute phase within 24 h after transcatheter aortic valve implantation (TAVI) for Heyde’s syndrome, or aortic stenosis complicated by gastrointestinal angiodysplasia and acquired coagulation dysfunction, have not been clarified. We evaluate...

Full description

Bibliographic Details
Main Authors: Kumi Fukuhara, Takashi Kondo, Hirotsugu Miyoshi, Hiroshi Hamada, Masashi Kawamoto
Format: Article
Language:English
Published: SpringerOpen 2019-01-01
Series:JA Clinical Reports
Subjects:
Online Access:http://link.springer.com/article/10.1186/s40981-019-0224-3
_version_ 1818968223244091392
author Kumi Fukuhara
Takashi Kondo
Hirotsugu Miyoshi
Hiroshi Hamada
Masashi Kawamoto
author_facet Kumi Fukuhara
Takashi Kondo
Hirotsugu Miyoshi
Hiroshi Hamada
Masashi Kawamoto
author_sort Kumi Fukuhara
collection DOAJ
description Abstract Background Changes in coagulability during the hyperacute phase within 24 h after transcatheter aortic valve implantation (TAVI) for Heyde’s syndrome, or aortic stenosis complicated by gastrointestinal angiodysplasia and acquired coagulation dysfunction, have not been clarified. We evaluated perioperative changes in coagulability using rotational thromboelastometry (ROTEM). Case presentation A female patient with Heyde’s syndrome in her 80s underwent TAVI. ROTEM showed coagulation dysfunction before and at 6 h after surgery. Improvements in coagulation function started at 12 h after surgery. Based on ROTEM findings, oral administration of antiplatelet agents was started on the day after surgery. No hemorrhagic complications were observed in the postoperative phase. Conclusions Evaluation of coagulation function using ROTEM was useful for monitoring perioperative hemostasis and coagulation in this patient.
first_indexed 2024-12-20T14:01:16Z
format Article
id doaj.art-23f3128fa5d3499f9e4487b2a9899160
institution Directory Open Access Journal
issn 2363-9024
language English
last_indexed 2024-12-20T14:01:16Z
publishDate 2019-01-01
publisher SpringerOpen
record_format Article
series JA Clinical Reports
spelling doaj.art-23f3128fa5d3499f9e4487b2a98991602022-12-21T19:38:22ZengSpringerOpenJA Clinical Reports2363-90242019-01-01511510.1186/s40981-019-0224-3Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantationKumi Fukuhara0Takashi Kondo1Hirotsugu Miyoshi2Hiroshi Hamada3Masashi Kawamoto4Department of Anesthesiology and Critical Care, Hiroshima University HospitalDepartment of Anesthesiology and Critical Care, Hiroshima University HospitalDepartment of Anesthesiology and Critical Care, Hiroshima University HospitalDepartment of Anesthesiology and Critical Care, Hiroshima University HospitalDepartment of Anesthesiology and Critical Care, Hiroshima University HospitalAbstract Background Changes in coagulability during the hyperacute phase within 24 h after transcatheter aortic valve implantation (TAVI) for Heyde’s syndrome, or aortic stenosis complicated by gastrointestinal angiodysplasia and acquired coagulation dysfunction, have not been clarified. We evaluated perioperative changes in coagulability using rotational thromboelastometry (ROTEM). Case presentation A female patient with Heyde’s syndrome in her 80s underwent TAVI. ROTEM showed coagulation dysfunction before and at 6 h after surgery. Improvements in coagulation function started at 12 h after surgery. Based on ROTEM findings, oral administration of antiplatelet agents was started on the day after surgery. No hemorrhagic complications were observed in the postoperative phase. Conclusions Evaluation of coagulation function using ROTEM was useful for monitoring perioperative hemostasis and coagulation in this patient.http://link.springer.com/article/10.1186/s40981-019-0224-3Heyde’s syndromeRotational thromboelastometryTranscatheter aortic valve implantation
spellingShingle Kumi Fukuhara
Takashi Kondo
Hirotsugu Miyoshi
Hiroshi Hamada
Masashi Kawamoto
Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation
JA Clinical Reports
Heyde’s syndrome
Rotational thromboelastometry
Transcatheter aortic valve implantation
title Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation
title_full Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation
title_fullStr Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation
title_full_unstemmed Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation
title_short Rotational thromboelastometry-guided perioperative management of coagulation in a patient with Heyde’s syndrome undergoing transcatheter aortic valve implantation
title_sort rotational thromboelastometry guided perioperative management of coagulation in a patient with heyde s syndrome undergoing transcatheter aortic valve implantation
topic Heyde’s syndrome
Rotational thromboelastometry
Transcatheter aortic valve implantation
url http://link.springer.com/article/10.1186/s40981-019-0224-3
work_keys_str_mv AT kumifukuhara rotationalthromboelastometryguidedperioperativemanagementofcoagulationinapatientwithheydessyndromeundergoingtranscatheteraorticvalveimplantation
AT takashikondo rotationalthromboelastometryguidedperioperativemanagementofcoagulationinapatientwithheydessyndromeundergoingtranscatheteraorticvalveimplantation
AT hirotsugumiyoshi rotationalthromboelastometryguidedperioperativemanagementofcoagulationinapatientwithheydessyndromeundergoingtranscatheteraorticvalveimplantation
AT hiroshihamada rotationalthromboelastometryguidedperioperativemanagementofcoagulationinapatientwithheydessyndromeundergoingtranscatheteraorticvalveimplantation
AT masashikawamoto rotationalthromboelastometryguidedperioperativemanagementofcoagulationinapatientwithheydessyndromeundergoingtranscatheteraorticvalveimplantation