Indoor air quality monitoring in metropolitan city Lahore: Using handheld devices

Introduction: Outdoor air pollution has been considered the primary issueby scientists and environmentalists for decades. With the advancement of technology, the activities of human are shifting from outdoor to indoor, urging researchers to investigate the indoor environment. Theerefore, the focus...

Full description

Bibliographic Details
Main Authors: Muhammad Muneeb Iqbal, Muhammad Shafiq
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2024-01-01
Series:Journal of Air Pollution and Health
Subjects:
Online Access:https://japh.tums.ac.ir/index.php/japh/article/view/593
_version_ 1797359813519212544
author Muhammad Muneeb Iqbal
Muhammad Shafiq
author_facet Muhammad Muneeb Iqbal
Muhammad Shafiq
author_sort Muhammad Muneeb Iqbal
collection DOAJ
description Introduction: Outdoor air pollution has been considered the primary issueby scientists and environmentalists for decades. With the advancement of technology, the activities of human are shifting from outdoor to indoor, urging researchers to investigate the indoor environment. Theerefore, the focus of this study is to examine indoor air quality in the metropolitan of Lahore. Materials and methods: The Temtop M2000C and Temtop H3 Laser monitors were used to collect data on Particulate Matter (PM), Carbon dioxide (CO2) concentration, Total Volatile Organic Compounds (TVOC), and formaldehyde (HCHO). The concentration of air pollutants in nine indoor areas was measured for a specified time interval. The values of particulate matter are measured to find the impact of the outdoor environment on the indoor environment. Results: The maximum average values of the particulate matter PM2.5 and PM10 were 488.6 μg/m³ and 737.2 6 μg/m³, respectively, which reduced drastically after the rain to 219 μg/m³ and 340 μg/m³, respectively. The maximum values of PM2.5 and PM10 during coal burning outside the room were 997.6 μg/m³ and 999.9 μg/m³, respectively, far higher than the values during normal conditions. TVOC and HCHO were found within the prescribed limits. Conclusion: The outcomes of this study established a deep impact of the outdoor environment on the indoor environment and recommend air purifiers to reduce the level of pollutants in the indoor environment.
first_indexed 2024-03-08T15:30:11Z
format Article
id doaj.art-244d61d64843471790dad1f7548e4593
institution Directory Open Access Journal
issn 2476-3071
language English
last_indexed 2024-03-08T15:30:11Z
publishDate 2024-01-01
publisher Tehran University of Medical Sciences
record_format Article
series Journal of Air Pollution and Health
spelling doaj.art-244d61d64843471790dad1f7548e45932024-01-10T06:10:31ZengTehran University of Medical SciencesJournal of Air Pollution and Health2476-30712024-01-018410.18502/japh.v8i4.14539Indoor air quality monitoring in metropolitan city Lahore: Using handheld devicesMuhammad Muneeb Iqbal0Muhammad Shafiq1Department of Industrial Engineering and Management, University of the Punjab, Lahore, PakistanDepartment of Industrial Engineering and Management, University of the Punjab, Lahore, Pakistan Introduction: Outdoor air pollution has been considered the primary issueby scientists and environmentalists for decades. With the advancement of technology, the activities of human are shifting from outdoor to indoor, urging researchers to investigate the indoor environment. Theerefore, the focus of this study is to examine indoor air quality in the metropolitan of Lahore. Materials and methods: The Temtop M2000C and Temtop H3 Laser monitors were used to collect data on Particulate Matter (PM), Carbon dioxide (CO2) concentration, Total Volatile Organic Compounds (TVOC), and formaldehyde (HCHO). The concentration of air pollutants in nine indoor areas was measured for a specified time interval. The values of particulate matter are measured to find the impact of the outdoor environment on the indoor environment. Results: The maximum average values of the particulate matter PM2.5 and PM10 were 488.6 μg/m³ and 737.2 6 μg/m³, respectively, which reduced drastically after the rain to 219 μg/m³ and 340 μg/m³, respectively. The maximum values of PM2.5 and PM10 during coal burning outside the room were 997.6 μg/m³ and 999.9 μg/m³, respectively, far higher than the values during normal conditions. TVOC and HCHO were found within the prescribed limits. Conclusion: The outcomes of this study established a deep impact of the outdoor environment on the indoor environment and recommend air purifiers to reduce the level of pollutants in the indoor environment. https://japh.tums.ac.ir/index.php/japh/article/view/593Indoor air quality; Particulate matter; Carbon dioxide; Volatile organic compound (VOC); Formaldehyde
spellingShingle Muhammad Muneeb Iqbal
Muhammad Shafiq
Indoor air quality monitoring in metropolitan city Lahore: Using handheld devices
Journal of Air Pollution and Health
Indoor air quality; Particulate matter; Carbon dioxide; Volatile organic compound (VOC); Formaldehyde
title Indoor air quality monitoring in metropolitan city Lahore: Using handheld devices
title_full Indoor air quality monitoring in metropolitan city Lahore: Using handheld devices
title_fullStr Indoor air quality monitoring in metropolitan city Lahore: Using handheld devices
title_full_unstemmed Indoor air quality monitoring in metropolitan city Lahore: Using handheld devices
title_short Indoor air quality monitoring in metropolitan city Lahore: Using handheld devices
title_sort indoor air quality monitoring in metropolitan city lahore using handheld devices
topic Indoor air quality; Particulate matter; Carbon dioxide; Volatile organic compound (VOC); Formaldehyde
url https://japh.tums.ac.ir/index.php/japh/article/view/593
work_keys_str_mv AT muhammadmuneebiqbal indoorairqualitymonitoringinmetropolitancitylahoreusinghandhelddevices
AT muhammadshafiq indoorairqualitymonitoringinmetropolitancitylahoreusinghandhelddevices