Lead Fractures after Vagal Nerve Stimulator Implantation

Objectives:Vagal nerve stimulator is an effective treatment option for the medical treatment of the resistant-epilepsies. Surgical complication risks, as well as device-dependent risks, are also present. In this study, we aimed to draw attention to lead fractures from device-dependent complications....

Full description

Bibliographic Details
Main Authors: Ahmet Eren SEÇEN, Ayfer ASLAN, Erkut Baha BULDUK, İrem YILDIRIM, Ayşe SERDAROĞLU, Gökhan KURT
Format: Article
Language:English
Published: Galenos Yayinevi 2019-12-01
Series:Archives of Epilepsy
Subjects:
Online Access: http://archepilepsy.org/archives/archive-detail/article-preview/lead-fractures-after-vagal-nerve-stimulator-mplant/54826
_version_ 1797767379908820992
author Ahmet Eren SEÇEN
Ayfer ASLAN
Erkut Baha BULDUK
İrem YILDIRIM
Ayşe SERDAROĞLU
Gökhan KURT
author_facet Ahmet Eren SEÇEN
Ayfer ASLAN
Erkut Baha BULDUK
İrem YILDIRIM
Ayşe SERDAROĞLU
Gökhan KURT
author_sort Ahmet Eren SEÇEN
collection DOAJ
description Objectives:Vagal nerve stimulator is an effective treatment option for the medical treatment of the resistant-epilepsies. Surgical complication risks, as well as device-dependent risks, are also present. In this study, we aimed to draw attention to lead fractures from device-dependent complications.Methods:Between March 2005 and March 2015, patients who had vagal nerve stimulator implantation were screened in our clinic, and patients with lead fractures were included in this study.Results:Vagal nerve stimulator implants were implanted to over 170 patients in our clinic, and 11 of them were found to have lead fractures. They were all taken to revision surgery.Conclusion:Although lead fractures are not common, they form 11% of the device-dependent complications. High seizure severity, frequent frequency, long seizures and trauma may cause lead fractures.
first_indexed 2024-03-12T20:38:53Z
format Article
id doaj.art-245cfc345a14405db11ac84c9fa2fa53
institution Directory Open Access Journal
issn 2792-0550
language English
last_indexed 2024-03-12T20:38:53Z
publishDate 2019-12-01
publisher Galenos Yayinevi
record_format Article
series Archives of Epilepsy
spelling doaj.art-245cfc345a14405db11ac84c9fa2fa532023-08-01T11:13:14ZengGalenos YayineviArchives of Epilepsy2792-05502019-12-0125313614010.14744/epilepsi.2018.9765913049054Lead Fractures after Vagal Nerve Stimulator ImplantationAhmet Eren SEÇEN0Ayfer ASLAN1Erkut Baha BULDUK2İrem YILDIRIM3Ayşe SERDAROĞLU4Gökhan KURT5 Department of Neurosurgery, University of Health Sciences, Fatih Sultan Mehmet Training and Research Hospital, İstanbul, Turkey Department of Neurosurgery, Şırnak State Hospital, Şırnak, Turkey Department of Neurosurgery, Eskişehir State Hospital, Eskişehir, Turkey Department of Neurology, Gazi University Faculty of Medicine, Ankara, Turkey Department of Pediatric Neurology, Gazi University Faculty of Medicine, Ankara, Turkey Department of Neurosurgery, Gazi University Faculty of Medicine, Ankara, Turkey Objectives:Vagal nerve stimulator is an effective treatment option for the medical treatment of the resistant-epilepsies. Surgical complication risks, as well as device-dependent risks, are also present. In this study, we aimed to draw attention to lead fractures from device-dependent complications.Methods:Between March 2005 and March 2015, patients who had vagal nerve stimulator implantation were screened in our clinic, and patients with lead fractures were included in this study.Results:Vagal nerve stimulator implants were implanted to over 170 patients in our clinic, and 11 of them were found to have lead fractures. They were all taken to revision surgery.Conclusion:Although lead fractures are not common, they form 11% of the device-dependent complications. High seizure severity, frequent frequency, long seizures and trauma may cause lead fractures. http://archepilepsy.org/archives/archive-detail/article-preview/lead-fractures-after-vagal-nerve-stimulator-mplant/54826 complicationlead fracturesvagus nerve stimulator
spellingShingle Ahmet Eren SEÇEN
Ayfer ASLAN
Erkut Baha BULDUK
İrem YILDIRIM
Ayşe SERDAROĞLU
Gökhan KURT
Lead Fractures after Vagal Nerve Stimulator Implantation
Archives of Epilepsy
complication
lead fractures
vagus nerve stimulator
title Lead Fractures after Vagal Nerve Stimulator Implantation
title_full Lead Fractures after Vagal Nerve Stimulator Implantation
title_fullStr Lead Fractures after Vagal Nerve Stimulator Implantation
title_full_unstemmed Lead Fractures after Vagal Nerve Stimulator Implantation
title_short Lead Fractures after Vagal Nerve Stimulator Implantation
title_sort lead fractures after vagal nerve stimulator implantation
topic complication
lead fractures
vagus nerve stimulator
url http://archepilepsy.org/archives/archive-detail/article-preview/lead-fractures-after-vagal-nerve-stimulator-mplant/54826
work_keys_str_mv AT ahmeterensecen leadfracturesaftervagalnervestimulatorimplantation
AT ayferaslan leadfracturesaftervagalnervestimulatorimplantation
AT erkutbahabulduk leadfracturesaftervagalnervestimulatorimplantation
AT iremyildirim leadfracturesaftervagalnervestimulatorimplantation
AT ayseserdaroglu leadfracturesaftervagalnervestimulatorimplantation
AT gokhankurt leadfracturesaftervagalnervestimulatorimplantation