Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity

Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Sergios Taliantzis,1 Asli Perente,1 Konstantinos Delibasis,2 Lambros T Doulos3 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biomedical Informatics...

Full description

Bibliographic Details
Main Authors: Labiris G, Panagiotopoulou EK, Taliantzis S, Perente A, Delibasis K, Doulos LT
Format: Article
Language:English
Published: Dove Medical Press 2021-11-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/lighting-standards-revisited-introduction-of-a-mathematical-model-for--peer-reviewed-fulltext-article-OPTH
_version_ 1818900091041218560
author Labiris G
Panagiotopoulou EK
Taliantzis S
Perente A
Delibasis K
Doulos LT
author_facet Labiris G
Panagiotopoulou EK
Taliantzis S
Perente A
Delibasis K
Doulos LT
author_sort Labiris G
collection DOAJ
description Georgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Sergios Taliantzis,1 Asli Perente,1 Konstantinos Delibasis,2 Lambros T Doulos3 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biomedical Informatics, University of Thessaly, Lamia, 35131, Greece; 3School of Applied Arts, Lighting Design, Hellenic Open University, Patras, 26335, GreeceCorrespondence: Georgios LabirisDepartment of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, GreeceTel +30 697 745 5027Fax +30 255 103 0405Email labiris@usa.netPurpose: Primary objective of present study is to introduce a contemporary methodology for the lighting standards update addressing both normophakic and pseudophakic patients.Methods: For the sake of our study, we theoretically estimated the intraocular-to-crystalline lens iIluminance ratio (ICIR) and the intraocular lens (IOL) luminous efficiency function VIOL(λ) as a new lighting benefit metric. Then, in a sample of 24 pseudophakic patients (38 eyes) implanted with the trifocal diffractive IOL Panoptix (SG) and in a control group (CG) of 28 normophakic participants (50 eyes), uncorrected distance visual acuity (UDVA) was measured at illuminance of 550lx (optimal UDVA). Following dark adaptation, illuminance was gradually raised from 20 lx until illuminance level that the patient reached his/her optimal UDVA. This measured illuminance at this point was defined as the minimum required illuminance level (MRIL). MRIL and UDVA for illuminance levels between 20 and 550lx in SG were compared with the corresponding values in CG. MRIL calculation allowed the construction of a predictive mathematical model that estimates the impact of environmental lighting on UDVA.Results: ICIR for Panoptix eyes ranged from 54.00% to 55.99%. Both groups had significantly higher UDVA at 550lx compared to 20lx (p < 0.05). CG had significantly higher UDVA than SG at 20lx (7.20 letters, p = 0.045), while no significant difference was detected at 550lx (0.40 letters, p = 0.883). SG required significantly more illuminance than CG to maintain their UDVA (MRILSG= 191.05lx, MRILCG= 122lx, p = 0.007). Our predictive model suggests suboptimal UDVA in a series of lighting directives for normophakic and Panoptix eyes.Conclusion: This is the first study to introduce the VIOL(λ) as a new lighting benefit metric and a mathematical model that quantifies the impact of illuminance on UDVA in normophakic and pseudophakic patients.Clinicaltrials.gov Identifier: NCT04263636.Keywords: multifocal intraocular lens, illuminance, light transmission, luminous efficiency function, lighting standards
first_indexed 2024-12-19T19:58:20Z
format Article
id doaj.art-24f4f5853fd24d39ba790b9090245639
institution Directory Open Access Journal
issn 1177-5483
language English
last_indexed 2024-12-19T19:58:20Z
publishDate 2021-11-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj.art-24f4f5853fd24d39ba790b90902456392022-12-21T20:07:44ZengDove Medical PressClinical Ophthalmology1177-54832021-11-01Volume 154553456470983Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual AcuityLabiris GPanagiotopoulou EKTaliantzis SPerente ADelibasis KDoulos LTGeorgios Labiris,1 Eirini-Kanella Panagiotopoulou,1 Sergios Taliantzis,1 Asli Perente,1 Konstantinos Delibasis,2 Lambros T Doulos3 1Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, Greece; 2Department of Computer Science and Biomedical Informatics, University of Thessaly, Lamia, 35131, Greece; 3School of Applied Arts, Lighting Design, Hellenic Open University, Patras, 26335, GreeceCorrespondence: Georgios LabirisDepartment of Ophthalmology, University Hospital of Alexandroupolis, Dragana, 68131, Alexandroupolis, GreeceTel +30 697 745 5027Fax +30 255 103 0405Email labiris@usa.netPurpose: Primary objective of present study is to introduce a contemporary methodology for the lighting standards update addressing both normophakic and pseudophakic patients.Methods: For the sake of our study, we theoretically estimated the intraocular-to-crystalline lens iIluminance ratio (ICIR) and the intraocular lens (IOL) luminous efficiency function VIOL(λ) as a new lighting benefit metric. Then, in a sample of 24 pseudophakic patients (38 eyes) implanted with the trifocal diffractive IOL Panoptix (SG) and in a control group (CG) of 28 normophakic participants (50 eyes), uncorrected distance visual acuity (UDVA) was measured at illuminance of 550lx (optimal UDVA). Following dark adaptation, illuminance was gradually raised from 20 lx until illuminance level that the patient reached his/her optimal UDVA. This measured illuminance at this point was defined as the minimum required illuminance level (MRIL). MRIL and UDVA for illuminance levels between 20 and 550lx in SG were compared with the corresponding values in CG. MRIL calculation allowed the construction of a predictive mathematical model that estimates the impact of environmental lighting on UDVA.Results: ICIR for Panoptix eyes ranged from 54.00% to 55.99%. Both groups had significantly higher UDVA at 550lx compared to 20lx (p < 0.05). CG had significantly higher UDVA than SG at 20lx (7.20 letters, p = 0.045), while no significant difference was detected at 550lx (0.40 letters, p = 0.883). SG required significantly more illuminance than CG to maintain their UDVA (MRILSG= 191.05lx, MRILCG= 122lx, p = 0.007). Our predictive model suggests suboptimal UDVA in a series of lighting directives for normophakic and Panoptix eyes.Conclusion: This is the first study to introduce the VIOL(λ) as a new lighting benefit metric and a mathematical model that quantifies the impact of illuminance on UDVA in normophakic and pseudophakic patients.Clinicaltrials.gov Identifier: NCT04263636.Keywords: multifocal intraocular lens, illuminance, light transmission, luminous efficiency function, lighting standardshttps://www.dovepress.com/lighting-standards-revisited-introduction-of-a-mathematical-model-for--peer-reviewed-fulltext-article-OPTHmultifocal intraocular lensilluminancelight transmissionluminous efficiency functionlighting standards
spellingShingle Labiris G
Panagiotopoulou EK
Taliantzis S
Perente A
Delibasis K
Doulos LT
Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity
Clinical Ophthalmology
multifocal intraocular lens
illuminance
light transmission
luminous efficiency function
lighting standards
title Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity
title_full Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity
title_fullStr Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity
title_full_unstemmed Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity
title_short Lighting Standards Revisited: Introduction of a Mathematical Model for the Assessment of the Impact of Illuminance on Visual Acuity
title_sort lighting standards revisited introduction of a mathematical model for the assessment of the impact of illuminance on visual acuity
topic multifocal intraocular lens
illuminance
light transmission
luminous efficiency function
lighting standards
url https://www.dovepress.com/lighting-standards-revisited-introduction-of-a-mathematical-model-for--peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT labirisg lightingstandardsrevisitedintroductionofamathematicalmodelfortheassessmentoftheimpactofilluminanceonvisualacuity
AT panagiotopoulouek lightingstandardsrevisitedintroductionofamathematicalmodelfortheassessmentoftheimpactofilluminanceonvisualacuity
AT taliantziss lightingstandardsrevisitedintroductionofamathematicalmodelfortheassessmentoftheimpactofilluminanceonvisualacuity
AT perentea lightingstandardsrevisitedintroductionofamathematicalmodelfortheassessmentoftheimpactofilluminanceonvisualacuity
AT delibasisk lightingstandardsrevisitedintroductionofamathematicalmodelfortheassessmentoftheimpactofilluminanceonvisualacuity
AT douloslt lightingstandardsrevisitedintroductionofamathematicalmodelfortheassessmentoftheimpactofilluminanceonvisualacuity