A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation
In recent years, cerebral blood oxygen saturation has become a key indicator during the perioperative period. Cerebral blood oxygen saturation monitoring is conducive to the early diagnosis and treatment of cerebral ischemia and hypoxia. The present study discusses the three most extensively used cl...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2021-08-01
|
Series: | Healthcare |
Subjects: | |
Online Access: | https://www.mdpi.com/2227-9032/9/9/1104 |
_version_ | 1797519019960434688 |
---|---|
author | Wentao Zhong Zhong Ji Changlong Sun |
author_facet | Wentao Zhong Zhong Ji Changlong Sun |
author_sort | Wentao Zhong |
collection | DOAJ |
description | In recent years, cerebral blood oxygen saturation has become a key indicator during the perioperative period. Cerebral blood oxygen saturation monitoring is conducive to the early diagnosis and treatment of cerebral ischemia and hypoxia. The present study discusses the three most extensively used clinical methods for cerebral blood oxygen saturation monitoring from different aspects: working principles, relevant parameters, current situations of research, commonly used equipment, and relative advantages of different methods. Furthermore, through comprehensive comparisons of the methods, we find that near-infrared spectroscopy (NIRS) technology has significant potentials and broad applications prospects in terms of cerebral oxygen saturation monitoring. Despite the current NIRS technology, the only bedside non-invasive cerebral oxygen saturation monitoring technology, still has many defects, it is more in line with the future development trend in the field of medical and health, and will become the main method gradually. |
first_indexed | 2024-03-10T07:37:26Z |
format | Article |
id | doaj.art-2569d995b9dd4189a6dda5435add838d |
institution | Directory Open Access Journal |
issn | 2227-9032 |
language | English |
last_indexed | 2024-03-10T07:37:26Z |
publishDate | 2021-08-01 |
publisher | MDPI AG |
record_format | Article |
series | Healthcare |
spelling | doaj.art-2569d995b9dd4189a6dda5435add838d2023-11-22T13:16:59ZengMDPI AGHealthcare2227-90322021-08-0199110410.3390/healthcare9091104A Review of Monitoring Methods for Cerebral Blood Oxygen SaturationWentao Zhong0Zhong Ji1Changlong Sun2College of Bioengineering, Chongqing University, Chongqing 400044, ChinaCollege of Bioengineering, Chongqing University, Chongqing 400044, ChinaCollege of Bioengineering, Chongqing University, Chongqing 400044, ChinaIn recent years, cerebral blood oxygen saturation has become a key indicator during the perioperative period. Cerebral blood oxygen saturation monitoring is conducive to the early diagnosis and treatment of cerebral ischemia and hypoxia. The present study discusses the three most extensively used clinical methods for cerebral blood oxygen saturation monitoring from different aspects: working principles, relevant parameters, current situations of research, commonly used equipment, and relative advantages of different methods. Furthermore, through comprehensive comparisons of the methods, we find that near-infrared spectroscopy (NIRS) technology has significant potentials and broad applications prospects in terms of cerebral oxygen saturation monitoring. Despite the current NIRS technology, the only bedside non-invasive cerebral oxygen saturation monitoring technology, still has many defects, it is more in line with the future development trend in the field of medical and health, and will become the main method gradually.https://www.mdpi.com/2227-9032/9/9/1104cerebral blood oxygen saturationmonitoringSjvO<sub>2</sub>PbtO<sub>2</sub>NIRSnon-invasive |
spellingShingle | Wentao Zhong Zhong Ji Changlong Sun A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation Healthcare cerebral blood oxygen saturation monitoring SjvO<sub>2</sub> PbtO<sub>2</sub> NIRS non-invasive |
title | A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation |
title_full | A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation |
title_fullStr | A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation |
title_full_unstemmed | A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation |
title_short | A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation |
title_sort | review of monitoring methods for cerebral blood oxygen saturation |
topic | cerebral blood oxygen saturation monitoring SjvO<sub>2</sub> PbtO<sub>2</sub> NIRS non-invasive |
url | https://www.mdpi.com/2227-9032/9/9/1104 |
work_keys_str_mv | AT wentaozhong areviewofmonitoringmethodsforcerebralbloodoxygensaturation AT zhongji areviewofmonitoringmethodsforcerebralbloodoxygensaturation AT changlongsun areviewofmonitoringmethodsforcerebralbloodoxygensaturation AT wentaozhong reviewofmonitoringmethodsforcerebralbloodoxygensaturation AT zhongji reviewofmonitoringmethodsforcerebralbloodoxygensaturation AT changlongsun reviewofmonitoringmethodsforcerebralbloodoxygensaturation |