Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors
We explored the nonlinear characteristics of energy resolution (ER) for the sealed NaI (Tl) scintillator detector by using a gamma-ray spectroscopy system and Monte Carlo simulation. Our research focused on the two primary factors of energy resolution including the photomultiplier tube (PMT) voltage...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2024-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2024/5206668 |
_version_ | 1827077444142628864 |
---|---|
author | Hongchi Zhou Fang Liu Xin Yuan Jun Wu Guanda Li |
author_facet | Hongchi Zhou Fang Liu Xin Yuan Jun Wu Guanda Li |
author_sort | Hongchi Zhou |
collection | DOAJ |
description | We explored the nonlinear characteristics of energy resolution (ER) for the sealed NaI (Tl) scintillator detector by using a gamma-ray spectroscopy system and Monte Carlo simulation. Our research focused on the two primary factors of energy resolution including the photomultiplier tube (PMT) voltage and the distance between the gamma-ray sources (137Cs and 60Co) and the scintillator detector. The experimental results showed that energy resolution decreased when the PMT voltage increased, and the energy resolution of NaI (Tl) detectors reached a smaller value (6.92%, 6.76%, and 6.56%), especially with the PMT voltage in the range of 575–595 V. In addition, a suitable distance between the gamma-ray source and the scintillator (5 cm) can also effectively reduce the energy resolution. We established the simulation models of the experimental NaI (Tl) detectors and simulated their energy spectra. The simulation results in the peak area agreed with the experimental results. A possible better PMT voltage choice has been proposed to obtain a smaller energy resolution. |
first_indexed | 2024-04-24T11:24:17Z |
format | Article |
id | doaj.art-26bd6edb4bd043448aa9ae55fef3e916 |
institution | Directory Open Access Journal |
issn | 1687-6083 |
language | English |
last_indexed | 2025-03-20T02:13:52Z |
publishDate | 2024-01-01 |
publisher | Hindawi Limited |
record_format | Article |
series | Science and Technology of Nuclear Installations |
spelling | doaj.art-26bd6edb4bd043448aa9ae55fef3e9162024-10-03T07:53:05ZengHindawi LimitedScience and Technology of Nuclear Installations1687-60832024-01-01202410.1155/2024/5206668Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator DetectorsHongchi Zhou0Fang Liu1Xin Yuan2Jun Wu3Guanda Li4Beijing Key Laboratory of Passive Safety Technology for Nuclear EnergyBeijing Key Laboratory of Passive Safety Technology for Nuclear EnergyBeijing Key Laboratory of Passive Safety Technology for Nuclear EnergyBeijing Key Laboratory of Passive Safety Technology for Nuclear EnergyBeijing Key Laboratory of Passive Safety Technology for Nuclear EnergyWe explored the nonlinear characteristics of energy resolution (ER) for the sealed NaI (Tl) scintillator detector by using a gamma-ray spectroscopy system and Monte Carlo simulation. Our research focused on the two primary factors of energy resolution including the photomultiplier tube (PMT) voltage and the distance between the gamma-ray sources (137Cs and 60Co) and the scintillator detector. The experimental results showed that energy resolution decreased when the PMT voltage increased, and the energy resolution of NaI (Tl) detectors reached a smaller value (6.92%, 6.76%, and 6.56%), especially with the PMT voltage in the range of 575–595 V. In addition, a suitable distance between the gamma-ray source and the scintillator (5 cm) can also effectively reduce the energy resolution. We established the simulation models of the experimental NaI (Tl) detectors and simulated their energy spectra. The simulation results in the peak area agreed with the experimental results. A possible better PMT voltage choice has been proposed to obtain a smaller energy resolution.http://dx.doi.org/10.1155/2024/5206668 |
spellingShingle | Hongchi Zhou Fang Liu Xin Yuan Jun Wu Guanda Li Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors Science and Technology of Nuclear Installations |
title | Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors |
title_full | Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors |
title_fullStr | Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors |
title_full_unstemmed | Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors |
title_short | Effect of Photomultiplier Tube Voltage on the Performance of Sealed NaI (Tl) Scintillator Detectors |
title_sort | effect of photomultiplier tube voltage on the performance of sealed nai tl scintillator detectors |
url | http://dx.doi.org/10.1155/2024/5206668 |
work_keys_str_mv | AT hongchizhou effectofphotomultipliertubevoltageontheperformanceofsealednaitlscintillatordetectors AT fangliu effectofphotomultipliertubevoltageontheperformanceofsealednaitlscintillatordetectors AT xinyuan effectofphotomultipliertubevoltageontheperformanceofsealednaitlscintillatordetectors AT junwu effectofphotomultipliertubevoltageontheperformanceofsealednaitlscintillatordetectors AT guandali effectofphotomultipliertubevoltageontheperformanceofsealednaitlscintillatordetectors |