Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation

The majority of contemporary total hip arthroplasty (THA) implants are constructed from Ti alloys, which are generally believed to generate fewer adverse local tissue reactions (ALTRs) compared to CoCr alloys. This study presents a case of unusual primary THA failure where a substantial release of T...

Full description

Bibliographic Details
Main Authors: Samo K. Fokter, Živa Ledinek, Milka Kljaić Dujić, Igor Novak
Format: Article
Language:English
Published: MDPI AG 2024-02-01
Series:Bioengineering
Subjects:
Online Access:https://www.mdpi.com/2306-5354/11/3/235
_version_ 1797241986203254784
author Samo K. Fokter
Živa Ledinek
Milka Kljaić Dujić
Igor Novak
author_facet Samo K. Fokter
Živa Ledinek
Milka Kljaić Dujić
Igor Novak
author_sort Samo K. Fokter
collection DOAJ
description The majority of contemporary total hip arthroplasty (THA) implants are constructed from Ti alloys, which are generally believed to generate fewer adverse local tissue reactions (ALTRs) compared to CoCr alloys. This study presents a case of unusual primary THA failure where a substantial release of Ti alloy debris was observed. A 52-year-old active male underwent THA after post-traumatic aseptic necrosis of the femoral head in 2006. Seventeen years after the procedure, the patient presented with groin pain and a restricted range of motion. X-rays revealed the protrusion of the alumina ceramic head through the Ti<sub>6</sub>Al<sub>4</sub>V acetabular cup. Trace element analysis indicated significantly elevated levels of serum Ti, Al, and V. CT and MRI confirmed Ti alloy cup failure and a severe ALTR. During revision surgery, it was found that the worn-out ceramic head was in direct contact with the acetabular cup, having protruded through a central hole it had created over time. No acetabular liner was found. Histological analysis of his tissue samples showed wear-induced synovitis with areas of multinucleated foreign body giant cells and the accumulation of numerous metal particles but no acute inflammatory response. Six months after the revision THA, the patient has experienced favourable outcomes. This case provides an instructive illustration for studying the consequences of the substantial release of Ti alloy debris from orthopedic implants.
first_indexed 2024-04-24T18:32:02Z
format Article
id doaj.art-26c3f3e2b6f94ada9da6d1388d7e77b8
institution Directory Open Access Journal
issn 2306-5354
language English
last_indexed 2024-04-24T18:32:02Z
publishDate 2024-02-01
publisher MDPI AG
record_format Article
series Bioengineering
spelling doaj.art-26c3f3e2b6f94ada9da6d1388d7e77b82024-03-27T13:21:50ZengMDPI AGBioengineering2306-53542024-02-0111323510.3390/bioengineering11030235Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris AccumulationSamo K. Fokter0Živa Ledinek1Milka Kljaić Dujić2Igor Novak3Clinical Department of Orthopedic Surgery, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, SloveniaDepartment of Pathology, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, SloveniaDepartment of Radiology, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, SloveniaClinical Department of Orthopedic Surgery, University Medical Centre Maribor, Ljubljanska 5, 2000 Maribor, SloveniaThe majority of contemporary total hip arthroplasty (THA) implants are constructed from Ti alloys, which are generally believed to generate fewer adverse local tissue reactions (ALTRs) compared to CoCr alloys. This study presents a case of unusual primary THA failure where a substantial release of Ti alloy debris was observed. A 52-year-old active male underwent THA after post-traumatic aseptic necrosis of the femoral head in 2006. Seventeen years after the procedure, the patient presented with groin pain and a restricted range of motion. X-rays revealed the protrusion of the alumina ceramic head through the Ti<sub>6</sub>Al<sub>4</sub>V acetabular cup. Trace element analysis indicated significantly elevated levels of serum Ti, Al, and V. CT and MRI confirmed Ti alloy cup failure and a severe ALTR. During revision surgery, it was found that the worn-out ceramic head was in direct contact with the acetabular cup, having protruded through a central hole it had created over time. No acetabular liner was found. Histological analysis of his tissue samples showed wear-induced synovitis with areas of multinucleated foreign body giant cells and the accumulation of numerous metal particles but no acute inflammatory response. Six months after the revision THA, the patient has experienced favourable outcomes. This case provides an instructive illustration for studying the consequences of the substantial release of Ti alloy debris from orthopedic implants.https://www.mdpi.com/2306-5354/11/3/235total hip arthroplastytitanium alloyorthopedic implantsimplant failureadverse local tissue reactions
spellingShingle Samo K. Fokter
Živa Ledinek
Milka Kljaić Dujić
Igor Novak
Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation
Bioengineering
total hip arthroplasty
titanium alloy
orthopedic implants
implant failure
adverse local tissue reactions
title Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation
title_full Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation
title_fullStr Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation
title_full_unstemmed Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation
title_short Extreme Serum Titanium Concentration Induced by Acetabular Cup Failure: Unveiling a Unique Scenario of Titanium Alloy Debris Accumulation
title_sort extreme serum titanium concentration induced by acetabular cup failure unveiling a unique scenario of titanium alloy debris accumulation
topic total hip arthroplasty
titanium alloy
orthopedic implants
implant failure
adverse local tissue reactions
url https://www.mdpi.com/2306-5354/11/3/235
work_keys_str_mv AT samokfokter extremeserumtitaniumconcentrationinducedbyacetabularcupfailureunveilingauniquescenariooftitaniumalloydebrisaccumulation
AT zivaledinek extremeserumtitaniumconcentrationinducedbyacetabularcupfailureunveilingauniquescenariooftitaniumalloydebrisaccumulation
AT milkakljaicdujic extremeserumtitaniumconcentrationinducedbyacetabularcupfailureunveilingauniquescenariooftitaniumalloydebrisaccumulation
AT igornovak extremeserumtitaniumconcentrationinducedbyacetabularcupfailureunveilingauniquescenariooftitaniumalloydebrisaccumulation