Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study

<i>Background:</i> Intrasaccular flow disruptors (IFD) have been introduced in the treatment of intracranial aneurysms (IAs) to overcome the low aneurysm occlusion rate and the high recanalization rate of the coiling technique. Among them, the Contour Neurovascular System (CNS) and the N...

Full description

Bibliographic Details
Main Authors: Francesco Diana, Marta de Dios Lascuevas, Simone Peschillo, Eytan Raz, Shinichi Yoshimura, Manuel Requena Ruiz, David Hernández Morales, Alejandro Tomasello
Format: Article
Language:English
Published: MDPI AG 2022-07-01
Series:Brain Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3425/12/8/991
_version_ 1827618051058565120
author Francesco Diana
Marta de Dios Lascuevas
Simone Peschillo
Eytan Raz
Shinichi Yoshimura
Manuel Requena Ruiz
David Hernández Morales
Alejandro Tomasello
author_facet Francesco Diana
Marta de Dios Lascuevas
Simone Peschillo
Eytan Raz
Shinichi Yoshimura
Manuel Requena Ruiz
David Hernández Morales
Alejandro Tomasello
author_sort Francesco Diana
collection DOAJ
description <i>Background:</i> Intrasaccular flow disruptors (IFD) have been introduced in the treatment of intracranial aneurysms (IAs) to overcome the low aneurysm occlusion rate and the high recanalization rate of the coiling technique. Among them, the Contour Neurovascular System (CNS) and the Neqstent (NQS) were designed to reconstruct the aneurysmal neck and both can be used as assisting coiling devices. We aimed to report our preliminary experience with the flow disruptor-assisted coiling (IFD-AC) technique. <i>Methods:</i> We performed a retrospective analysis of prospectively collected data of all patients with IAs treated with the IFD-AC. <i>Results:</i> Between February 2021 and April 2022, we treated 15 IAs with the IFD-AC: 10 ruptured and 5 unruptured. The IFD-AC was successfully performed in 13 cases, with a post-operative RROC 1 in 12 cases (92.3%) and RROC 2 in 1 case (7.7%). There was one ischemic event (6.7%) and no hemorrhagic complications. Twelve patients underwent a mid-term radiologic follow-up: Ten IAs (83.4%) presented an adequate occlusion, while 2 (16.7%) had a recurrence. <i>Conclusions:</i> The IFD-AC, both with the CNS and the NQS, seems a safe technique with promising efficacy profile. The IFD-AC has proved to be safe without antiplatelet therapy in ruptured cases. Further studies are needed to confirm our preliminary results.
first_indexed 2024-03-09T09:59:05Z
format Article
id doaj.art-26de3cbfda784063b2677c626dec3ab4
institution Directory Open Access Journal
issn 2076-3425
language English
last_indexed 2024-03-09T09:59:05Z
publishDate 2022-07-01
publisher MDPI AG
record_format Article
series Brain Sciences
spelling doaj.art-26de3cbfda784063b2677c626dec3ab42023-12-01T23:30:53ZengMDPI AGBrain Sciences2076-34252022-07-0112899110.3390/brainsci12080991Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility StudyFrancesco Diana0Marta de Dios Lascuevas1Simone Peschillo2Eytan Raz3Shinichi Yoshimura4Manuel Requena Ruiz5David Hernández Morales6Alejandro Tomasello7Neuroradiology, University Hospital ‘San Giovanni di Dio e Ruggi d’Aragona’, 84125 Salerno, ItalyNeuroradiology, Vall d’Hebron Hospital Universitari, 08035 Barcelona, SpainUniCamillus International Medical University, 00131 Rome, ItalyDepartment of Radiology, NYU Langone Health, New York, NY 10016, USADepartment of Neurosurgery, Hyogo College of Medicine, Nishinomiya 663-8501, JapanNeuroradiology, Vall d’Hebron Hospital Universitari, 08035 Barcelona, SpainNeuroradiology, Vall d’Hebron Hospital Universitari, 08035 Barcelona, SpainNeuroradiology, Vall d’Hebron Hospital Universitari, 08035 Barcelona, Spain<i>Background:</i> Intrasaccular flow disruptors (IFD) have been introduced in the treatment of intracranial aneurysms (IAs) to overcome the low aneurysm occlusion rate and the high recanalization rate of the coiling technique. Among them, the Contour Neurovascular System (CNS) and the Neqstent (NQS) were designed to reconstruct the aneurysmal neck and both can be used as assisting coiling devices. We aimed to report our preliminary experience with the flow disruptor-assisted coiling (IFD-AC) technique. <i>Methods:</i> We performed a retrospective analysis of prospectively collected data of all patients with IAs treated with the IFD-AC. <i>Results:</i> Between February 2021 and April 2022, we treated 15 IAs with the IFD-AC: 10 ruptured and 5 unruptured. The IFD-AC was successfully performed in 13 cases, with a post-operative RROC 1 in 12 cases (92.3%) and RROC 2 in 1 case (7.7%). There was one ischemic event (6.7%) and no hemorrhagic complications. Twelve patients underwent a mid-term radiologic follow-up: Ten IAs (83.4%) presented an adequate occlusion, while 2 (16.7%) had a recurrence. <i>Conclusions:</i> The IFD-AC, both with the CNS and the NQS, seems a safe technique with promising efficacy profile. The IFD-AC has proved to be safe without antiplatelet therapy in ruptured cases. Further studies are needed to confirm our preliminary results.https://www.mdpi.com/2076-3425/12/8/991brain aneurysmsendovascular treatmentcoilingassisted coilingintrasaccular devicesflow disruptor
spellingShingle Francesco Diana
Marta de Dios Lascuevas
Simone Peschillo
Eytan Raz
Shinichi Yoshimura
Manuel Requena Ruiz
David Hernández Morales
Alejandro Tomasello
Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study
Brain Sciences
brain aneurysms
endovascular treatment
coiling
assisted coiling
intrasaccular devices
flow disruptor
title Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study
title_full Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study
title_fullStr Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study
title_full_unstemmed Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study
title_short Intrasaccular Flow Disruptor-Assisted Coiling of Intracranial Aneurysms Using the Novel Contour Neurovascular Systems and NEQSTENT: A Single-Center Safety and Feasibility Study
title_sort intrasaccular flow disruptor assisted coiling of intracranial aneurysms using the novel contour neurovascular systems and neqstent a single center safety and feasibility study
topic brain aneurysms
endovascular treatment
coiling
assisted coiling
intrasaccular devices
flow disruptor
url https://www.mdpi.com/2076-3425/12/8/991
work_keys_str_mv AT francescodiana intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy
AT martadedioslascuevas intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy
AT simonepeschillo intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy
AT eytanraz intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy
AT shinichiyoshimura intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy
AT manuelrequenaruiz intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy
AT davidhernandezmorales intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy
AT alejandrotomasello intrasaccularflowdisruptorassistedcoilingofintracranialaneurysmsusingthenovelcontourneurovascularsystemsandneqstentasinglecentersafetyandfeasibilitystudy