Overview of shopping malls ventilation and air conditioning energy-efficient system control needs

The article is devoted to the analysis of design-specific features and microclimate control problems searching of the shopping malls. The main trends of shopping malls development are formulated. It is shown that Fagner indices and ISO 7730: 2005, ISO 10551: 2019 standards are used to evaluate human...

Full description

Bibliographic Details
Main Authors: P.O., О.M.
Format: Article
Language:English
Published: Zhytomyr Polytechnic State University 2022-06-01
Series:Технічна інженерія
Subjects:
Online Access:http://ten.ztu.edu.ua/article/view/260816
_version_ 1797944744452554752
author P.O.
О.M.
author_facet P.O.
О.M.
author_sort P.O.
collection DOAJ
description The article is devoted to the analysis of design-specific features and microclimate control problems searching of the shopping malls. The main trends of shopping malls development are formulated. It is shown that Fagner indices and ISO 7730: 2005, ISO 10551: 2019 standards are used to evaluate human comfort indoors. It has been established that improper usage of shopping malls ventilation can be a cause of visitors’ and employees’ illnesses. It was found that parameters that need to be controlled are not limited to typical like temperature and humidity. It is proposed to make measurements of the following parameters: carbon monoxide, PM2.5 and PM10 particles, carbon dioxide (CO2), formaldehyde (HCHO), volatile organic compounds (TVOC). It is shown that human comfort in the shopping mall creation is an important task that needs to be solved in conjunction with energy saving. The main parameters of the microclimate that should be used in system control synthesis are given. The main shopping malls devices of technological processes automation control manufacturers are presented. It is emphasized that energy efficiency approaches are divided into constructive and algorithmic. The constructive approaches implementation is possible only if the shopping center was built in compliance with all regulatory requirements of premises construction. A review of control laws and modeling methods that are used in heating and ventilation systems control is provided. The basic principles of energy resources saving are formulated. It is determined that shopping center is an object with distributed parameters due to its size and separate conditions for each room creation needs. It is shown that classical approaches that are proposed to be used for temperature and humidity processes of the object with distributed parameters control are not suitable for its energy efficiency.
first_indexed 2024-04-10T20:43:26Z
format Article
id doaj.art-271c84c143954cf1aa4fcb9c5b5043d8
institution Directory Open Access Journal
issn 2706-5847
2707-9619
language English
last_indexed 2024-04-10T20:43:26Z
publishDate 2022-06-01
publisher Zhytomyr Polytechnic State University
record_format Article
series Технічна інженерія
spelling doaj.art-271c84c143954cf1aa4fcb9c5b5043d82023-01-24T11:52:01ZengZhytomyr Polytechnic State UniversityТехнічна інженерія2706-58472707-96192022-06-01189697610.26642/ten-2022-1(89)-69-76Overview of shopping malls ventilation and air conditioning energy-efficient system control needsP.O. 0https://orcid.org/0000-0002-0781-0853О.M. 1https://orcid.org/0000-0001-5432-1211KachanovYevseienkoThe article is devoted to the analysis of design-specific features and microclimate control problems searching of the shopping malls. The main trends of shopping malls development are formulated. It is shown that Fagner indices and ISO 7730: 2005, ISO 10551: 2019 standards are used to evaluate human comfort indoors. It has been established that improper usage of shopping malls ventilation can be a cause of visitors’ and employees’ illnesses. It was found that parameters that need to be controlled are not limited to typical like temperature and humidity. It is proposed to make measurements of the following parameters: carbon monoxide, PM2.5 and PM10 particles, carbon dioxide (CO2), formaldehyde (HCHO), volatile organic compounds (TVOC). It is shown that human comfort in the shopping mall creation is an important task that needs to be solved in conjunction with energy saving. The main parameters of the microclimate that should be used in system control synthesis are given. The main shopping malls devices of technological processes automation control manufacturers are presented. It is emphasized that energy efficiency approaches are divided into constructive and algorithmic. The constructive approaches implementation is possible only if the shopping center was built in compliance with all regulatory requirements of premises construction. A review of control laws and modeling methods that are used in heating and ventilation systems control is provided. The basic principles of energy resources saving are formulated. It is determined that shopping center is an object with distributed parameters due to its size and separate conditions for each room creation needs. It is shown that classical approaches that are proposed to be used for temperature and humidity processes of the object with distributed parameters control are not suitable for its energy efficiency.http://ten.ztu.edu.ua/article/view/260816shopping centerenergy savingautomated control systemmicroclimatecomfort index
spellingShingle P.O.
О.M.
Overview of shopping malls ventilation and air conditioning energy-efficient system control needs
Технічна інженерія
shopping center
energy saving
automated control system
microclimate
comfort index
title Overview of shopping malls ventilation and air conditioning energy-efficient system control needs
title_full Overview of shopping malls ventilation and air conditioning energy-efficient system control needs
title_fullStr Overview of shopping malls ventilation and air conditioning energy-efficient system control needs
title_full_unstemmed Overview of shopping malls ventilation and air conditioning energy-efficient system control needs
title_short Overview of shopping malls ventilation and air conditioning energy-efficient system control needs
title_sort overview of shopping malls ventilation and air conditioning energy efficient system control needs
topic shopping center
energy saving
automated control system
microclimate
comfort index
url http://ten.ztu.edu.ua/article/view/260816
work_keys_str_mv AT po overviewofshoppingmallsventilationandairconditioningenergyefficientsystemcontrolneeds
AT om overviewofshoppingmallsventilationandairconditioningenergyefficientsystemcontrolneeds