Recommended procedure for headroom design according to geometric parameters of building structures

The system of Czech technical standards for geometric accuracy assumes that the designer determines the functional geometric parameters for a specific building. By calculation, he verifies them in the so-called “geometric plan” in the project documentation. The functional geometric parameters should...

Full description

Bibliographic Details
Main Author: Linda Veselá
Format: Article
Language:English
Published: CTU Central Library 2022-12-01
Series:Acta Polytechnica
Subjects:
Online Access:https://ojs.cvut.cz/ojs/index.php/ap/article/view/8335
_version_ 1797948710762577920
author Linda Veselá
author_facet Linda Veselá
author_sort Linda Veselá
collection DOAJ
description The system of Czech technical standards for geometric accuracy assumes that the designer determines the functional geometric parameters for a specific building. By calculation, he verifies them in the so-called “geometric plan” in the project documentation. The functional geometric parameters should be determined primarily for critical elements, i.e. for structures whose geometric accuracy is important for the execution of subsequent works, such as technologies requiring high precision and specific structures. The assumption is that designers will incorporate variations in geometric accuracy primarily in the development of the spatial parameters of the structures, which should ensure that the dimensional requirements for the completed structures will be met. One of these parameters is headroom. The design of headroom must respect the minimum height requirements prescribed by legislation, and where appropriate, by technical standards. At the same time, the design must respect the technological possibilities of the construction of individual structures – geometric deviations. To comply with the dimensional requirements for the completed structures, the geometric accuracy deviations should be determined in accordance with the requirements of the technical standards for the execution of the individual parts of the building structures and/or for their design. The aim of this article is to establish a calculation procedure for determining the safe design clearance so that the requirements of the legislation are met after implementation. The increase is determined based on a calculation procedure of the limiting geometric deviations that may affect the resulting headroom.
first_indexed 2024-04-10T21:47:39Z
format Article
id doaj.art-28329a7d1e4644ad94bc6513446ed6da
institution Directory Open Access Journal
issn 1805-2363
language English
last_indexed 2024-04-10T21:47:39Z
publishDate 2022-12-01
publisher CTU Central Library
record_format Article
series Acta Polytechnica
spelling doaj.art-28329a7d1e4644ad94bc6513446ed6da2023-01-18T13:45:09ZengCTU Central LibraryActa Polytechnica1805-23632022-12-0162665465910.14311/AP.2022.62.06545575Recommended procedure for headroom design according to geometric parameters of building structuresLinda Veselá0Czech Technical University in Prague, Faculty of Civil Engineering, Department of Construction Technology, Thákurova 7, 160 00 Prague, Czech RepublicThe system of Czech technical standards for geometric accuracy assumes that the designer determines the functional geometric parameters for a specific building. By calculation, he verifies them in the so-called “geometric plan” in the project documentation. The functional geometric parameters should be determined primarily for critical elements, i.e. for structures whose geometric accuracy is important for the execution of subsequent works, such as technologies requiring high precision and specific structures. The assumption is that designers will incorporate variations in geometric accuracy primarily in the development of the spatial parameters of the structures, which should ensure that the dimensional requirements for the completed structures will be met. One of these parameters is headroom. The design of headroom must respect the minimum height requirements prescribed by legislation, and where appropriate, by technical standards. At the same time, the design must respect the technological possibilities of the construction of individual structures – geometric deviations. To comply with the dimensional requirements for the completed structures, the geometric accuracy deviations should be determined in accordance with the requirements of the technical standards for the execution of the individual parts of the building structures and/or for their design. The aim of this article is to establish a calculation procedure for determining the safe design clearance so that the requirements of the legislation are met after implementation. The increase is determined based on a calculation procedure of the limiting geometric deviations that may affect the resulting headroom.https://ojs.cvut.cz/ojs/index.php/ap/article/view/8335headroomgeometric accuracylimit deviationgeometric accuracy deviation
spellingShingle Linda Veselá
Recommended procedure for headroom design according to geometric parameters of building structures
Acta Polytechnica
headroom
geometric accuracy
limit deviation
geometric accuracy deviation
title Recommended procedure for headroom design according to geometric parameters of building structures
title_full Recommended procedure for headroom design according to geometric parameters of building structures
title_fullStr Recommended procedure for headroom design according to geometric parameters of building structures
title_full_unstemmed Recommended procedure for headroom design according to geometric parameters of building structures
title_short Recommended procedure for headroom design according to geometric parameters of building structures
title_sort recommended procedure for headroom design according to geometric parameters of building structures
topic headroom
geometric accuracy
limit deviation
geometric accuracy deviation
url https://ojs.cvut.cz/ojs/index.php/ap/article/view/8335
work_keys_str_mv AT lindavesela recommendedprocedureforheadroomdesignaccordingtogeometricparametersofbuildingstructures