A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor

Accurate estimation of heart rates from photoplethysmogram (PPG) signals during intense physical activity is a very challenging problem. This is because strenuous and high intensity exercise can result in severe motion artifacts in PPG signals, making accurate heart rate (HR) estimation difficult. I...

Full description

Bibliographic Details
Main Authors: Seyed M. A. Salehizadeh, Duy Dao, Jeffrey Bolkhovsky, Chae Cho, Yitzhak Mendelson, Ki H. Chon
Format: Article
Language:English
Published: MDPI AG 2015-12-01
Series:Sensors
Subjects:
Online Access:http://www.mdpi.com/1424-8220/16/1/10
_version_ 1798004015898820608
author Seyed M. A. Salehizadeh
Duy Dao
Jeffrey Bolkhovsky
Chae Cho
Yitzhak Mendelson
Ki H. Chon
author_facet Seyed M. A. Salehizadeh
Duy Dao
Jeffrey Bolkhovsky
Chae Cho
Yitzhak Mendelson
Ki H. Chon
author_sort Seyed M. A. Salehizadeh
collection DOAJ
description Accurate estimation of heart rates from photoplethysmogram (PPG) signals during intense physical activity is a very challenging problem. This is because strenuous and high intensity exercise can result in severe motion artifacts in PPG signals, making accurate heart rate (HR) estimation difficult. In this study we investigated a novel technique to accurately reconstruct motion-corrupted PPG signals and HR based on time-varying spectral analysis. The algorithm is called Spectral filter algorithm for Motion Artifacts and heart rate reconstruction (SpaMA). The idea is to calculate the power spectral density of both PPG and accelerometer signals for each time shift of a windowed data segment. By comparing time-varying spectra of PPG and accelerometer data, those frequency peaks resulting from motion artifacts can be distinguished from the PPG spectrum. The SpaMA approach was applied to three different datasets and four types of activities: (1) training datasets from the 2015 IEEE Signal Process. Cup Database recorded from 12 subjects while performing treadmill exercise from 1 km/h to 15 km/h; (2) test datasets from the 2015 IEEE Signal Process. Cup Database recorded from 11 subjects while performing forearm and upper arm exercise. (3) Chon Lab dataset including 10 min recordings from 10 subjects during treadmill exercise. The ECG signals from all three datasets provided the reference HRs which were used to determine the accuracy of our SpaMA algorithm. The performance of the SpaMA approach was calculated by computing the mean absolute error between the estimated HR from the PPG and the reference HR from the ECG. The average estimation errors using our method on the first, second and third datasets are 0.89, 1.93 and 1.38 beats/min respectively, while the overall error on all 33 subjects is 1.86 beats/min and the performance on only treadmill experiment datasets (22 subjects) is 1.11 beats/min. Moreover, it was found that dynamics of heart rate variability can be accurately captured using the algorithm where the mean Pearson’s correlation coefficient between the power spectral densities of the reference and the reconstructed heart rate time series was found to be 0.98. These results show that the SpaMA method has a potential for PPG-based HR monitoring in wearable devices for fitness tracking and health monitoring during intense physical activities.
first_indexed 2024-04-11T12:16:52Z
format Article
id doaj.art-29aafa8b97a04249befc9190c982cfdd
institution Directory Open Access Journal
issn 1424-8220
language English
last_indexed 2024-04-11T12:16:52Z
publishDate 2015-12-01
publisher MDPI AG
record_format Article
series Sensors
spelling doaj.art-29aafa8b97a04249befc9190c982cfdd2022-12-22T04:24:15ZengMDPI AGSensors1424-82202015-12-0116110010.3390/s16010010s16010010A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram SensorSeyed M. A. Salehizadeh0Duy Dao1Jeffrey Bolkhovsky2Chae Cho3Yitzhak Mendelson4Ki H. Chon5Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USADepartment of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USADepartment of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USADepartment of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USADepartment of Biomedical Engineering, Worcester Polytechnic Institution, Worcester, MA 01609, USADepartment of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USAAccurate estimation of heart rates from photoplethysmogram (PPG) signals during intense physical activity is a very challenging problem. This is because strenuous and high intensity exercise can result in severe motion artifacts in PPG signals, making accurate heart rate (HR) estimation difficult. In this study we investigated a novel technique to accurately reconstruct motion-corrupted PPG signals and HR based on time-varying spectral analysis. The algorithm is called Spectral filter algorithm for Motion Artifacts and heart rate reconstruction (SpaMA). The idea is to calculate the power spectral density of both PPG and accelerometer signals for each time shift of a windowed data segment. By comparing time-varying spectra of PPG and accelerometer data, those frequency peaks resulting from motion artifacts can be distinguished from the PPG spectrum. The SpaMA approach was applied to three different datasets and four types of activities: (1) training datasets from the 2015 IEEE Signal Process. Cup Database recorded from 12 subjects while performing treadmill exercise from 1 km/h to 15 km/h; (2) test datasets from the 2015 IEEE Signal Process. Cup Database recorded from 11 subjects while performing forearm and upper arm exercise. (3) Chon Lab dataset including 10 min recordings from 10 subjects during treadmill exercise. The ECG signals from all three datasets provided the reference HRs which were used to determine the accuracy of our SpaMA algorithm. The performance of the SpaMA approach was calculated by computing the mean absolute error between the estimated HR from the PPG and the reference HR from the ECG. The average estimation errors using our method on the first, second and third datasets are 0.89, 1.93 and 1.38 beats/min respectively, while the overall error on all 33 subjects is 1.86 beats/min and the performance on only treadmill experiment datasets (22 subjects) is 1.11 beats/min. Moreover, it was found that dynamics of heart rate variability can be accurately captured using the algorithm where the mean Pearson’s correlation coefficient between the power spectral densities of the reference and the reconstructed heart rate time series was found to be 0.98. These results show that the SpaMA method has a potential for PPG-based HR monitoring in wearable devices for fitness tracking and health monitoring during intense physical activities.http://www.mdpi.com/1424-8220/16/1/10motion artifactheart rate monitoringphotoplethysmogrphyphysical activitiessignal processing
spellingShingle Seyed M. A. Salehizadeh
Duy Dao
Jeffrey Bolkhovsky
Chae Cho
Yitzhak Mendelson
Ki H. Chon
A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
Sensors
motion artifact
heart rate monitoring
photoplethysmogrphy
physical activities
signal processing
title A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
title_full A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
title_fullStr A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
title_full_unstemmed A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
title_short A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor
title_sort novel time varying spectral filtering algorithm for reconstruction of motion artifact corrupted heart rate signals during intense physical activities using a wearable photoplethysmogram sensor
topic motion artifact
heart rate monitoring
photoplethysmogrphy
physical activities
signal processing
url http://www.mdpi.com/1424-8220/16/1/10
work_keys_str_mv AT seyedmasalehizadeh anoveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT duydao anoveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT jeffreybolkhovsky anoveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT chaecho anoveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT yitzhakmendelson anoveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT kihchon anoveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT seyedmasalehizadeh noveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT duydao noveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT jeffreybolkhovsky noveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT chaecho noveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT yitzhakmendelson noveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor
AT kihchon noveltimevaryingspectralfilteringalgorithmforreconstructionofmotionartifactcorruptedheartratesignalsduringintensephysicalactivitiesusingawearablephotoplethysmogramsensor