Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera device

Objective. To study the correlations between corneal distortion and morphological features in different kinds of eyes such as healthy ones (HE), ones previously undergone myopic PRK (PRKE), ones affected by keratoconus (KCE) and keratoconus eyes previously undergone corneal collagen crosslinking (CC...

Full description

Bibliographic Details
Main Authors: Sbordone S., Ragucci A., Iaccarino G., Scognamiglio G., Serra L., Gironi Carnevale U.A., Lanza M.
Format: Article
Language:English
Published: Ukrainian Society of Ophthalmologists 2021-10-01
Series:Journal of Ophthalmology
Subjects:
Online Access:https://www.ozhurnal.com/en/archive/2021/5/3-fulltext
_version_ 1797392784083124224
author Sbordone S.
Ragucci A.
Iaccarino G.
Scognamiglio G.
Serra L.
Gironi Carnevale U.A.
Lanza M.
author_facet Sbordone S.
Ragucci A.
Iaccarino G.
Scognamiglio G.
Serra L.
Gironi Carnevale U.A.
Lanza M.
author_sort Sbordone S.
collection DOAJ
description Objective. To study the correlations between corneal distortion and morphological features in different kinds of eyes such as healthy ones (HE), ones previously undergone myopic PRK (PRKE), ones affected by keratoconus (KCE) and keratoconus eyes previously undergone corneal collagen crosslinking (CCCE). Materials and Methods. In this retrospective comparative study, a total of 106 HE of 106 patients, 58 PRKE of 58 patients, 33 KCE of 33 patients, 28 CCCE of 28 patients were included. A complete examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Germany) and biomechanical (Corvis ST, Oculus, Wetzlar, Germany) evaluation. Differences among Corvis ST (CST) parameters in the different groups have been analyzed. Linear regressions between central corneal thickness (CCT), intraocular pressure (IOP) and anterior corneal curvature measured with Simulated Keratometry (SK), versus corneal deformation parameters measured with Corvis ST in the different groups, have been run using SPSS software version 18.0. Results, HE showed a significant correlation between main curvature power of the cornea within the central 3 mm expressed in Diopters (KM) and 6 CST parameters; between CCT and 4 CST parameters and between IOP and 5 CST parameters. PRKE showed a significant correlation between KM and 3 CST parameters; between IOP and 4 CST parameters and none between CCT and CST parameters. KCE showed a significant correlation between SK and 3 CST parameters; between IOP and 3 CST parameters and none between CCT and CST parameters. CCCE showed a significant correlation between KM and 5 CST parameters; between CCT and 1 CST parameters and between IOP and 5 CST parameters. Discussion. Data of this study suggest that both corneal curvature and IOP could have a greater influence on the corneal deformation, compared to central corneal thickness (CCT). These results should be taken into account by further studies aiming to assess biomechanical corneal characteristics.
first_indexed 2024-03-08T23:52:32Z
format Article
id doaj.art-29adfa7497094122b9627f5c48a4c572
institution Directory Open Access Journal
issn 2412-8740
language English
last_indexed 2024-03-08T23:52:32Z
publishDate 2021-10-01
publisher Ukrainian Society of Ophthalmologists
record_format Article
series Journal of Ophthalmology
spelling doaj.art-29adfa7497094122b9627f5c48a4c5722023-12-13T10:15:45ZengUkrainian Society of OphthalmologistsJournal of Ophthalmology2412-87402021-10-015142010.31288/oftalmolzh202151420Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera deviceSbordone S.0Ragucci A.1Iaccarino G.2Scognamiglio G.3Serra L.4Gironi Carnevale U.A.5Lanza M.6Università degli studi della Campania “L. Vanvitelli”Università degli studi della Campania “L. Vanvitelli”Università degli studi della Campania “L. Vanvitelli”Università degli studi della Campania “L. Vanvitelli”Università degli studi della Campania “L. Vanvitelli”Università degli studi della Campania “L. Vanvitelli”Università degli studi della Campania “L. Vanvitelli”Objective. To study the correlations between corneal distortion and morphological features in different kinds of eyes such as healthy ones (HE), ones previously undergone myopic PRK (PRKE), ones affected by keratoconus (KCE) and keratoconus eyes previously undergone corneal collagen crosslinking (CCCE). Materials and Methods. In this retrospective comparative study, a total of 106 HE of 106 patients, 58 PRKE of 58 patients, 33 KCE of 33 patients, 28 CCCE of 28 patients were included. A complete examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Germany) and biomechanical (Corvis ST, Oculus, Wetzlar, Germany) evaluation. Differences among Corvis ST (CST) parameters in the different groups have been analyzed. Linear regressions between central corneal thickness (CCT), intraocular pressure (IOP) and anterior corneal curvature measured with Simulated Keratometry (SK), versus corneal deformation parameters measured with Corvis ST in the different groups, have been run using SPSS software version 18.0. Results, HE showed a significant correlation between main curvature power of the cornea within the central 3 mm expressed in Diopters (KM) and 6 CST parameters; between CCT and 4 CST parameters and between IOP and 5 CST parameters. PRKE showed a significant correlation between KM and 3 CST parameters; between IOP and 4 CST parameters and none between CCT and CST parameters. KCE showed a significant correlation between SK and 3 CST parameters; between IOP and 3 CST parameters and none between CCT and CST parameters. CCCE showed a significant correlation between KM and 5 CST parameters; between CCT and 1 CST parameters and between IOP and 5 CST parameters. Discussion. Data of this study suggest that both corneal curvature and IOP could have a greater influence on the corneal deformation, compared to central corneal thickness (CCT). These results should be taken into account by further studies aiming to assess biomechanical corneal characteristics.https://www.ozhurnal.com/en/archive/2021/5/3-fulltextсorneal deformationcorneal crosslinkingcorvis stkeratoconusrefractive surgery
spellingShingle Sbordone S.
Ragucci A.
Iaccarino G.
Scognamiglio G.
Serra L.
Gironi Carnevale U.A.
Lanza M.
Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera device
Journal of Ophthalmology
сorneal deformation
corneal crosslinking
corvis st
keratoconus
refractive surgery
title Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera device
title_full Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera device
title_fullStr Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera device
title_full_unstemmed Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera device
title_short Evaluation of corneal distortion characteristics in different eyes using Scheimpflug camera device
title_sort evaluation of corneal distortion characteristics in different eyes using scheimpflug camera device
topic сorneal deformation
corneal crosslinking
corvis st
keratoconus
refractive surgery
url https://www.ozhurnal.com/en/archive/2021/5/3-fulltext
work_keys_str_mv AT sbordones evaluationofcornealdistortioncharacteristicsindifferenteyesusingscheimpflugcameradevice
AT raguccia evaluationofcornealdistortioncharacteristicsindifferenteyesusingscheimpflugcameradevice
AT iaccarinog evaluationofcornealdistortioncharacteristicsindifferenteyesusingscheimpflugcameradevice
AT scognamigliog evaluationofcornealdistortioncharacteristicsindifferenteyesusingscheimpflugcameradevice
AT serral evaluationofcornealdistortioncharacteristicsindifferenteyesusingscheimpflugcameradevice
AT gironicarnevaleua evaluationofcornealdistortioncharacteristicsindifferenteyesusingscheimpflugcameradevice
AT lanzam evaluationofcornealdistortioncharacteristicsindifferenteyesusingscheimpflugcameradevice