Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction

Despite inconclusive and conflicting results of trials and meta-analyses assessing aspiration thrombectomy in ST-segment elevation myocardial infarction (STEMI), trends toward reduced mortality were observed in the high thrombus burden subgroup [1–3]. With a large thrombus being one of the strongest...

Full description

Bibliographic Details
Main Authors: Jacek Klaudel, Dariusz Surman, Krzysztof Pawłowski, Wojciech Trenkner
Format: Article
Language:English
Published: Termedia Publishing House 2022-04-01
Series:Advances in Interventional Cardiology
Online Access:https://www.termedia.pl/Stroke-thrombectomy-catheter-for-aspiration-of-refractory-or-inaccessible-clot-in-acute-myocardial-infarction,35,46830,1,1.html
_version_ 1811302601673670656
author Jacek Klaudel
Dariusz Surman
Krzysztof Pawłowski
Wojciech Trenkner
author_facet Jacek Klaudel
Dariusz Surman
Krzysztof Pawłowski
Wojciech Trenkner
author_sort Jacek Klaudel
collection DOAJ
description Despite inconclusive and conflicting results of trials and meta-analyses assessing aspiration thrombectomy in ST-segment elevation myocardial infarction (STEMI), trends toward reduced mortality were observed in the high thrombus burden subgroup [1–3]. With a large thrombus being one of the strongest predictors of the no flow phenomenon, manual thromboaspiration remains an effective method of its prevention, especially in patients who cannot undergo a staged procedure after IIB/IIIA inhibitor administration because satisfactory reperfusion has not been achieved during the initial intervention [4–8]. Since standard monorail coronary aspiration devices are often ineffective in the case of a large thrombus, guide extension catheters have been used for clot extraction. Their bigger lumen comes at a cost of worse trackability and a higher risk of artery dissection [9].
first_indexed 2024-04-13T07:32:12Z
format Article
id doaj.art-29d25d688d954b50ac74acab255caefb
institution Directory Open Access Journal
issn 1734-9338
1897-4295
language English
last_indexed 2024-04-13T07:32:12Z
publishDate 2022-04-01
publisher Termedia Publishing House
record_format Article
series Advances in Interventional Cardiology
spelling doaj.art-29d25d688d954b50ac74acab255caefb2022-12-22T02:56:20ZengTermedia Publishing HouseAdvances in Interventional Cardiology1734-93381897-42952022-04-01181656910.5114/aic.2022.11529946830Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarctionJacek KlaudelDariusz SurmanKrzysztof PawłowskiWojciech TrenknerDespite inconclusive and conflicting results of trials and meta-analyses assessing aspiration thrombectomy in ST-segment elevation myocardial infarction (STEMI), trends toward reduced mortality were observed in the high thrombus burden subgroup [1–3]. With a large thrombus being one of the strongest predictors of the no flow phenomenon, manual thromboaspiration remains an effective method of its prevention, especially in patients who cannot undergo a staged procedure after IIB/IIIA inhibitor administration because satisfactory reperfusion has not been achieved during the initial intervention [4–8]. Since standard monorail coronary aspiration devices are often ineffective in the case of a large thrombus, guide extension catheters have been used for clot extraction. Their bigger lumen comes at a cost of worse trackability and a higher risk of artery dissection [9].https://www.termedia.pl/Stroke-thrombectomy-catheter-for-aspiration-of-refractory-or-inaccessible-clot-in-acute-myocardial-infarction,35,46830,1,1.html
spellingShingle Jacek Klaudel
Dariusz Surman
Krzysztof Pawłowski
Wojciech Trenkner
Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction
Advances in Interventional Cardiology
title Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction
title_full Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction
title_fullStr Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction
title_full_unstemmed Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction
title_short Stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction
title_sort stroke thrombectomy catheter for aspiration of refractory or inaccessible clot in acute myocardial infarction
url https://www.termedia.pl/Stroke-thrombectomy-catheter-for-aspiration-of-refractory-or-inaccessible-clot-in-acute-myocardial-infarction,35,46830,1,1.html
work_keys_str_mv AT jacekklaudel strokethrombectomycatheterforaspirationofrefractoryorinaccessibleclotinacutemyocardialinfarction
AT dariuszsurman strokethrombectomycatheterforaspirationofrefractoryorinaccessibleclotinacutemyocardialinfarction
AT krzysztofpawłowski strokethrombectomycatheterforaspirationofrefractoryorinaccessibleclotinacutemyocardialinfarction
AT wojciechtrenkner strokethrombectomycatheterforaspirationofrefractoryorinaccessibleclotinacutemyocardialinfarction