The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study

Purpose: Accurate refraction is arguably the most important parameter for a successful laser vision correction surgery and is based on a combination of manifest and cycloplegic refraction. Wavefront-based objective refraction may be useful in the evaluation of patients. So far, the reliability of ob...

Full description

Bibliographic Details
Main Authors: Kepa Balparda, Andrea Acevedo-Urrego, Laura Andrea Silva-Quintero, Tatiana Herrera-Chalarca
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2022-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2022;volume=70;issue=5;spage=1533;epage=1537;aulast=Balparda
_version_ 1828820794534264832
author Kepa Balparda
Andrea Acevedo-Urrego
Laura Andrea Silva-Quintero
Tatiana Herrera-Chalarca
author_facet Kepa Balparda
Andrea Acevedo-Urrego
Laura Andrea Silva-Quintero
Tatiana Herrera-Chalarca
author_sort Kepa Balparda
collection DOAJ
description Purpose: Accurate refraction is arguably the most important parameter for a successful laser vision correction surgery and is based on a combination of manifest and cycloplegic refraction. Wavefront-based objective refraction may be useful in the evaluation of patients. So far, the reliability of objective refraction as measured using the Pentacam® AXL Wave has not been published in the literature. Methods: This was a prospective study including a total of 168 eyes belonging to 84 young non-presbyopic patients evaluated for refractive surgery. Pentacam® AXL Wave full sequence was taken for all patients. Then, a clinician who was unaware of the objective refraction results performed a full physical examination, including manifest refraction starting from an autorefractometer value. All refraction values were transferred to astigmatic power vectors as per the Thibos method. Reliability of the different vectors and a unifying blur value were compared using Spearman correlation, Bland–Altman plot, and intraclass correlation coefficient. Results: The mean age was 28.8 ± 5.4 years, with a female preponderance (60.7%). The correlation between both eyes was high. The difference in M vector between subjective and objective refraction was 0.16 D, while the difference was 0.04 and 0.01 D for the J0 and J45 vectors, respectively. Paired samples Student t was non-significant for all comparisons. Spearman rho correlations were high (0.666–0.924, all P < 0.001). Intraclass correlation coefficients were also high (0.890–0.966). Bland–Altman plots did not demonstrate any systematic errors. Conclusion: Wavefront-based refractive refraction obtained using the Pentacam® AXL Wave is highly agreeable and correlated with measurements obtained by manifest subjective refraction.
first_indexed 2024-12-12T12:41:27Z
format Article
id doaj.art-29f7237c676e4ca69a62ca54468e130f
institution Directory Open Access Journal
issn 0301-4738
1998-3689
language English
last_indexed 2024-12-12T12:41:27Z
publishDate 2022-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Ophthalmology
spelling doaj.art-29f7237c676e4ca69a62ca54468e130f2022-12-22T00:24:13ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892022-01-017051533153710.4103/ijo.IJO_3006_21The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective studyKepa BalpardaAndrea Acevedo-UrregoLaura Andrea Silva-QuinteroTatiana Herrera-ChalarcaPurpose: Accurate refraction is arguably the most important parameter for a successful laser vision correction surgery and is based on a combination of manifest and cycloplegic refraction. Wavefront-based objective refraction may be useful in the evaluation of patients. So far, the reliability of objective refraction as measured using the Pentacam® AXL Wave has not been published in the literature. Methods: This was a prospective study including a total of 168 eyes belonging to 84 young non-presbyopic patients evaluated for refractive surgery. Pentacam® AXL Wave full sequence was taken for all patients. Then, a clinician who was unaware of the objective refraction results performed a full physical examination, including manifest refraction starting from an autorefractometer value. All refraction values were transferred to astigmatic power vectors as per the Thibos method. Reliability of the different vectors and a unifying blur value were compared using Spearman correlation, Bland–Altman plot, and intraclass correlation coefficient. Results: The mean age was 28.8 ± 5.4 years, with a female preponderance (60.7%). The correlation between both eyes was high. The difference in M vector between subjective and objective refraction was 0.16 D, while the difference was 0.04 and 0.01 D for the J0 and J45 vectors, respectively. Paired samples Student t was non-significant for all comparisons. Spearman rho correlations were high (0.666–0.924, all P < 0.001). Intraclass correlation coefficients were also high (0.890–0.966). Bland–Altman plots did not demonstrate any systematic errors. Conclusion: Wavefront-based refractive refraction obtained using the Pentacam® AXL Wave is highly agreeable and correlated with measurements obtained by manifest subjective refraction.http://www.ijo.in/article.asp?issn=0301-4738;year=2022;volume=70;issue=5;spage=1533;epage=1537;aulast=Balpardaobjective refractionpentacamrefractive surgical proceduressubjective refraction
spellingShingle Kepa Balparda
Andrea Acevedo-Urrego
Laura Andrea Silva-Quintero
Tatiana Herrera-Chalarca
The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study
Indian Journal of Ophthalmology
objective refraction
pentacam
refractive surgical procedures
subjective refraction
title The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study
title_full The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study
title_fullStr The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study
title_full_unstemmed The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study
title_short The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study
title_sort pentacam r axl wave provides a reliable wavefront based objective refraction when compared to manifest subjective refraction a prospective study
topic objective refraction
pentacam
refractive surgical procedures
subjective refraction
url http://www.ijo.in/article.asp?issn=0301-4738;year=2022;volume=70;issue=5;spage=1533;epage=1537;aulast=Balparda
work_keys_str_mv AT kepabalparda thepentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy
AT andreaacevedourrego thepentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy
AT lauraandreasilvaquintero thepentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy
AT tatianaherrerachalarca thepentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy
AT kepabalparda pentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy
AT andreaacevedourrego pentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy
AT lauraandreasilvaquintero pentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy
AT tatianaherrerachalarca pentacamaxlwaveprovidesareliablewavefrontbasedobjectiverefractionwhencomparedtomanifestsubjectiverefractionaprospectivestudy