Efficient Upper Limb Position Estimation Based on Angular Displacement Sensors for Wearable Devices

Motion tracking techniques have been extensively studied in recent years. However, capturing movements of the upper limbs is a challenging task. This document presents the estimation of arm orientation and elbow and wrist position using wearable flexible sensors (WFSs). A study was developed to obta...

Full description

Bibliographic Details
Main Authors: Aldo-Francisco Contreras-González, Manuel Ferre, Miguel Ángel Sánchez-Urán, Francisco Javier Sáez-Sáez, Fernando Blaya Haro
Format: Article
Language:English
Published: MDPI AG 2020-11-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/22/6452
Description
Summary:Motion tracking techniques have been extensively studied in recent years. However, capturing movements of the upper limbs is a challenging task. This document presents the estimation of arm orientation and elbow and wrist position using wearable flexible sensors (WFSs). A study was developed to obtain the highest range of motion (ROM) of the shoulder with as few sensors as possible, and a method for estimating arm length and a calibration procedure was proposed. Performance was verified by comparing measurement of the shoulder joint angles obtained from commercial two-axis soft angular displacement sensors (sADS) from Bend Labs and from the ground truth system (GTS) OptiTrack. The global root-mean-square error (RMSE) for the shoulder angle is 2.93 degrees and 37.5 mm for the position estimation of the wrist in cyclical movements; this measure of RMSE was improved to 13.6 mm by implementing a gesture classifier.
ISSN:1424-8220