Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients

Introduction: Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ecta...

Full description

Bibliographic Details
Main Author: Tamer Adel Refai
Format: Article
Language:English
Published: Electronic Physician 2015-10-01
Series:Electronic Physician
Subjects:
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623802/
_version_ 1818837212401238016
author Tamer Adel Refai
author_facet Tamer Adel Refai
author_sort Tamer Adel Refai
collection DOAJ
description Introduction: Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasia. The aim of this work was to find out if there is a statistically significant correlation between these different predictors and their correlation with the central corneal thickness for refractive non-keratoconic Egyptian patients trying to achieve a better decision and avoiding ectasia. Methods: This case-control study involved 142 eyes (of 77 patients with various refractive errors) arriving at the refractive surgery unit in the Research Institute of Ophthalmology in Giza (Egypt) in 2014-2015 seeking excimer laser ablation. The flattest, steepest keratometry readings, central corneal thickness as well as the apical protrusion in the central 4-mm ring, both for the anterior and posterior floats, in microns were measured by Scheimflug imaging. The Corneal Hysteresis and Corneal Resistance Factor were measured by the ocular response analyzer. Statistical analysis was performed by SPSS, using the Pearson correlation test. Results: The spherical refractive error ranged from +7.00 to -13.00 diopters (-3.80 ± 2.89). The central pachymetry ranged from 494 to 634 µm (550.35 ± 32.13). For the central 4-mm ring, the apical protrusion ranged from 0 to +15 µ (6.93 ± 2.99) for the anterior float and from -3 to +20 µ (9.33 ± 4.55) for the posterior float. The Corneal Hysterisis (CH) ranged from 7 to 14.8 mmHg (10.18±1.44), while the Corneal Resistance Factor (CRF) ranged from 7.5 to 14.9 mmHg (10.58 ± 1.67). There was a strong positive correlation between the central corneal thickness and both Corneal Hysteresis (CH: r = 0.56, P ≤ 0.01) and Corneal Resistance Factor (r = 0.46, P ≤ 0.01). A significant correlation (P < 0.05, r = 0.15) existed between apical protrusion in the posterior float and the central corneal thickness. Also, significant negative correlation (P < 0.05, r = -0.12) existed between apical protrusion in the anterior float by pentacam and the Corneal Resistance Factor by ocular response analyzer. Conclusions: Our finding of a strong positive correlation between both Corneal Hysteresis and Corneal Resistance Factor and the Central corneal thickness being important for biomechanical corneal stability. The findings of this study also support using both machines preoperatively to decrease the risk of post-Lasik ectasia.
first_indexed 2024-12-19T03:18:55Z
format Article
id doaj.art-2a81ce42f589459f8e8926b5dcde3722
institution Directory Open Access Journal
issn 2008-5842
2008-5842
language English
last_indexed 2024-12-19T03:18:55Z
publishDate 2015-10-01
publisher Electronic Physician
record_format Article
series Electronic Physician
spelling doaj.art-2a81ce42f589459f8e8926b5dcde37222022-12-21T20:37:48ZengElectronic PhysicianElectronic Physician2008-58422008-58422015-10-01761394139810.14661/1394Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patientsTamer Adel RefaiIntroduction: Apical protrusion in the central 4-mm ring in the Scheimflug imaging (Pentacam), both for the anterior and posterior floats as well as Corneal Hysteresis and Corneal Resistance Factor by Ocular Response Analyzer (ORA), generally are considered important predictors for post-Lasik ectasia. The aim of this work was to find out if there is a statistically significant correlation between these different predictors and their correlation with the central corneal thickness for refractive non-keratoconic Egyptian patients trying to achieve a better decision and avoiding ectasia. Methods: This case-control study involved 142 eyes (of 77 patients with various refractive errors) arriving at the refractive surgery unit in the Research Institute of Ophthalmology in Giza (Egypt) in 2014-2015 seeking excimer laser ablation. The flattest, steepest keratometry readings, central corneal thickness as well as the apical protrusion in the central 4-mm ring, both for the anterior and posterior floats, in microns were measured by Scheimflug imaging. The Corneal Hysteresis and Corneal Resistance Factor were measured by the ocular response analyzer. Statistical analysis was performed by SPSS, using the Pearson correlation test. Results: The spherical refractive error ranged from +7.00 to -13.00 diopters (-3.80 ± 2.89). The central pachymetry ranged from 494 to 634 µm (550.35 ± 32.13). For the central 4-mm ring, the apical protrusion ranged from 0 to +15 µ (6.93 ± 2.99) for the anterior float and from -3 to +20 µ (9.33 ± 4.55) for the posterior float. The Corneal Hysterisis (CH) ranged from 7 to 14.8 mmHg (10.18±1.44), while the Corneal Resistance Factor (CRF) ranged from 7.5 to 14.9 mmHg (10.58 ± 1.67). There was a strong positive correlation between the central corneal thickness and both Corneal Hysteresis (CH: r = 0.56, P ≤ 0.01) and Corneal Resistance Factor (r = 0.46, P ≤ 0.01). A significant correlation (P < 0.05, r = 0.15) existed between apical protrusion in the posterior float and the central corneal thickness. Also, significant negative correlation (P < 0.05, r = -0.12) existed between apical protrusion in the anterior float by pentacam and the Corneal Resistance Factor by ocular response analyzer. Conclusions: Our finding of a strong positive correlation between both Corneal Hysteresis and Corneal Resistance Factor and the Central corneal thickness being important for biomechanical corneal stability. The findings of this study also support using both machines preoperatively to decrease the risk of post-Lasik ectasia.https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623802/apical protrusionocular response analyzer (ORA)Lasik
spellingShingle Tamer Adel Refai
Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients
Electronic Physician
apical protrusion
ocular response analyzer (ORA)
Lasik
title Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients
title_full Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients
title_fullStr Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients
title_full_unstemmed Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients
title_short Correlation between apical protrusion in the Scheimflug imaging and Corneal Hysteresis and Corneal Resistance factor by Ocular Response Analyzer, among refractive non-keratoconic Egyptian patients
title_sort correlation between apical protrusion in the scheimflug imaging and corneal hysteresis and corneal resistance factor by ocular response analyzer among refractive non keratoconic egyptian patients
topic apical protrusion
ocular response analyzer (ORA)
Lasik
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4623802/
work_keys_str_mv AT tameradelrefai correlationbetweenapicalprotrusioninthescheimflugimagingandcornealhysteresisandcornealresistancefactorbyocularresponseanalyzeramongrefractivenonkeratoconicegyptianpatients