Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat Recovery

This study investigates the thermal efficiency and exergy efficiency of a thermoelectric power generation device for recovering power cable surface waste heat. Numerical simulations are conducted to analyze the impact of different types of cooling fins on the system’s performance. The results demons...

Full description

Bibliographic Details
Main Authors: Zihao Hu, Francisco de León, Rizhou Wang, Yanzhe Li
Format: Article
Language:English
Published: MDPI AG 2023-08-01
Series:Micromachines
Subjects:
Online Access:https://www.mdpi.com/2072-666X/14/8/1591
_version_ 1797583743837274112
author Zihao Hu
Francisco de León
Rizhou Wang
Yanzhe Li
author_facet Zihao Hu
Francisco de León
Rizhou Wang
Yanzhe Li
author_sort Zihao Hu
collection DOAJ
description This study investigates the thermal efficiency and exergy efficiency of a thermoelectric power generation device for recovering power cable surface waste heat. Numerical simulations are conducted to analyze the impact of different types of cooling fins on the system’s performance. The results demonstrate that the installation of cooling fins improves heat transfer efficiency and enhances the thermoelectric power generation device’s output power. Among the various fin designs, the system equipped with cooling fins with 17 teeth exhibits the highest performance. These findings highlight the importance of fin design in optimizing the system’s thermal efficiency and exergy efficiency. This study provides valuable insights for the development and improvement of thermoelectric power generation systems for power cable surface waste heat recovery applications.
first_indexed 2024-03-10T23:43:23Z
format Article
id doaj.art-2ab3c8142291476d8993027d34938920
institution Directory Open Access Journal
issn 2072-666X
language English
last_indexed 2024-03-10T23:43:23Z
publishDate 2023-08-01
publisher MDPI AG
record_format Article
series Micromachines
spelling doaj.art-2ab3c8142291476d8993027d349389202023-11-19T02:14:06ZengMDPI AGMicromachines2072-666X2023-08-01148159110.3390/mi14081591Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat RecoveryZihao Hu0Francisco de León1Rizhou Wang2Yanzhe Li3Department of Electrical and Computer Engineering, Tandon School of Engineering, New York University, New York, NY 11201, USADepartment of Electrical and Computer Engineering, Tandon School of Engineering, New York University, New York, NY 11201, USADepartment of Electrical and Computer Engineering, Tandon School of Engineering, New York University, New York, NY 11201, USADepartment of Electrical and Computer Engineering, Tandon School of Engineering, New York University, New York, NY 11201, USAThis study investigates the thermal efficiency and exergy efficiency of a thermoelectric power generation device for recovering power cable surface waste heat. Numerical simulations are conducted to analyze the impact of different types of cooling fins on the system’s performance. The results demonstrate that the installation of cooling fins improves heat transfer efficiency and enhances the thermoelectric power generation device’s output power. Among the various fin designs, the system equipped with cooling fins with 17 teeth exhibits the highest performance. These findings highlight the importance of fin design in optimizing the system’s thermal efficiency and exergy efficiency. This study provides valuable insights for the development and improvement of thermoelectric power generation systems for power cable surface waste heat recovery applications.https://www.mdpi.com/2072-666X/14/8/1591thermoelectric power generation devicepower cablecooling finsthermal efficiencyexergy efficiency
spellingShingle Zihao Hu
Francisco de León
Rizhou Wang
Yanzhe Li
Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat Recovery
Micromachines
thermoelectric power generation device
power cable
cooling fins
thermal efficiency
exergy efficiency
title Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat Recovery
title_full Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat Recovery
title_fullStr Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat Recovery
title_full_unstemmed Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat Recovery
title_short Effects of Installing Different Types of Cooling Fins on the Cold Side of a Thermoelectric Power Generation Device on the Thermal Efficiency and Exergy Efficiency of Power Cable Surface Waste Heat Recovery
title_sort effects of installing different types of cooling fins on the cold side of a thermoelectric power generation device on the thermal efficiency and exergy efficiency of power cable surface waste heat recovery
topic thermoelectric power generation device
power cable
cooling fins
thermal efficiency
exergy efficiency
url https://www.mdpi.com/2072-666X/14/8/1591
work_keys_str_mv AT zihaohu effectsofinstallingdifferenttypesofcoolingfinsonthecoldsideofathermoelectricpowergenerationdeviceonthethermalefficiencyandexergyefficiencyofpowercablesurfacewasteheatrecovery
AT franciscodeleon effectsofinstallingdifferenttypesofcoolingfinsonthecoldsideofathermoelectricpowergenerationdeviceonthethermalefficiencyandexergyefficiencyofpowercablesurfacewasteheatrecovery
AT rizhouwang effectsofinstallingdifferenttypesofcoolingfinsonthecoldsideofathermoelectricpowergenerationdeviceonthethermalefficiencyandexergyefficiencyofpowercablesurfacewasteheatrecovery
AT yanzheli effectsofinstallingdifferenttypesofcoolingfinsonthecoldsideofathermoelectricpowergenerationdeviceonthethermalefficiencyandexergyefficiencyofpowercablesurfacewasteheatrecovery