The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-Up
Necessary mechanical energy needed for initiation of self-dependent combustion engine work is transferred by crankshaft driving using an electrical starter. Changes of values of the static resistant moment and start-up resistant moment in the engine influence current input by the electric starter du...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
University of Žilina
2006-06-01
|
Series: | Communications |
Subjects: | |
Online Access: | https://komunikacie.uniza.sk/artkey/csl-200602-0007_the-influence-of-vehicle-maintenance-conditions-on-chosen-electric-parameters-of-starter-during-combustion-engi.php |
_version_ | 1797847011228123136 |
---|---|
author | Pawel Drozdziel |
author_facet | Pawel Drozdziel |
author_sort | Pawel Drozdziel |
collection | DOAJ |
description | Necessary mechanical energy needed for initiation of self-dependent combustion engine work is transferred by crankshaft driving using an electrical starter. Changes of values of the static resistant moment and start-up resistant moment in the engine influence current input by the electric starter during start-up of the combustion engine. Overloads observed in the vehicle electric power system are the results of high value of current intensity input by the electric starter. It seems very important to find the answer how the vehicle maintenance conditions influence the chosen working electric parameters of the starter during the combustion engine start-up. This article presents the results of investigations of starting working electric parameters during a combustion engine start-up, made during the vehicle maintenance. |
first_indexed | 2024-04-09T18:05:21Z |
format | Article |
id | doaj.art-2b0138dc2fb44eb6beae8c964d366da3 |
institution | Directory Open Access Journal |
issn | 1335-4205 2585-7878 |
language | English |
last_indexed | 2024-04-09T18:05:21Z |
publishDate | 2006-06-01 |
publisher | University of Žilina |
record_format | Article |
series | Communications |
spelling | doaj.art-2b0138dc2fb44eb6beae8c964d366da32023-04-14T06:29:48ZengUniversity of ŽilinaCommunications1335-42052585-78782006-06-0182535810.26552/com.C.2006.2.53-58csl-200602-0007The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-UpPawel Drozdziel0Department of Machine Design, Mechanical Faculty, Lublin University of Technology, PolandNecessary mechanical energy needed for initiation of self-dependent combustion engine work is transferred by crankshaft driving using an electrical starter. Changes of values of the static resistant moment and start-up resistant moment in the engine influence current input by the electric starter during start-up of the combustion engine. Overloads observed in the vehicle electric power system are the results of high value of current intensity input by the electric starter. It seems very important to find the answer how the vehicle maintenance conditions influence the chosen working electric parameters of the starter during the combustion engine start-up. This article presents the results of investigations of starting working electric parameters during a combustion engine start-up, made during the vehicle maintenance.https://komunikacie.uniza.sk/artkey/csl-200602-0007_the-influence-of-vehicle-maintenance-conditions-on-chosen-electric-parameters-of-starter-during-combustion-engi.phpno keywords |
spellingShingle | Pawel Drozdziel The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-Up Communications no keywords |
title | The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-Up |
title_full | The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-Up |
title_fullStr | The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-Up |
title_full_unstemmed | The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-Up |
title_short | The Influence of Vehicle Maintenance Conditions on Chosen Electric Parameters of Starter During Combustion Engine Start-Up |
title_sort | influence of vehicle maintenance conditions on chosen electric parameters of starter during combustion engine start up |
topic | no keywords |
url | https://komunikacie.uniza.sk/artkey/csl-200602-0007_the-influence-of-vehicle-maintenance-conditions-on-chosen-electric-parameters-of-starter-during-combustion-engi.php |
work_keys_str_mv | AT paweldrozdziel theinfluenceofvehiclemaintenanceconditionsonchosenelectricparametersofstarterduringcombustionenginestartup AT paweldrozdziel influenceofvehiclemaintenanceconditionsonchosenelectricparametersofstarterduringcombustionenginestartup |