QuEChERS-HPLC-DAD method for sulphonamides in chicken breast

The development of a QuEChERS-HPLC-DAD method using a Lichrospher 60 RP-Select B column (250 x 4.6 mm x 5 µm) at 40ºC, mobile phase constituted by phosphate buffer:acetonitrile (75:25, v/v) at a initial flow rate of 0.5 mL min-1, increased by 1.2 mL min-1 and at 265 nm is presented for simultaneous...

Full description

Bibliographic Details
Main Authors: Simone Caetani Machado, Mariane Landin-Silva, Patrícia Penido Maia, Susanne Rath, Isarita Martins
Format: Article
Language:English
Published: Universidade de São Paulo 2013-03-01
Series:Brazilian Journal of Pharmaceutical Sciences
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502013000100017
_version_ 1819049184570900480
author Simone Caetani Machado
Mariane Landin-Silva
Patrícia Penido Maia
Susanne Rath
Isarita Martins
author_facet Simone Caetani Machado
Mariane Landin-Silva
Patrícia Penido Maia
Susanne Rath
Isarita Martins
author_sort Simone Caetani Machado
collection DOAJ
description The development of a QuEChERS-HPLC-DAD method using a Lichrospher 60 RP-Select B column (250 x 4.6 mm x 5 µm) at 40ºC, mobile phase constituted by phosphate buffer:acetonitrile (75:25, v/v) at a initial flow rate of 0.5 mL min-1, increased by 1.2 mL min-1 and at 265 nm is presented for simultaneous determination of sulphadiazine, sulphametoxipiridazine and sulphamethoxazole in chicken breast samples. QuEchERS is inexpensive, fast and easy, and the extraction of the analytes of the matrix was successfully employed. In addition, the method presented linearity, in the range of 25, 50, 100, 150, 175, and 200 µg kg-1, precision, selectivity and sensitivity. The intraday precision (RSD %) for QuEChERS method was between 3.6-10.8 (SDZ), 6.9-14.1 (SPZ) and 1.9-10.9 (SMX) and interday precision (RSD%) was between 1.5-9.7, 1.7-4.1 and 2.1-10.2, respectively. Results of accuracy (bias) were in the range of -8.6 to +11.9 %. Therefore, the validated method is clearly useful for the practical residue monitoring of the drugs evaluated in chicken samples, as all the values were within the acceptable criteria used for food safety. Of 6 samples analyzed, none of them showed contamination of the sulphonamides studied at detectable levels.<br>O desenvolvimento de um método QuEChERS-HPLC-DAD usando uma coluna Lichrospher RP-60 Select B (250 x 4,6 mm x 5 µm) a 40 ºC, fase móvel constituída por tampão de fosfato: acetonitrila (75:25, v/v) a uma vazão inicial de 0,5 mL min-1, aumentando 1,2 mL min-1 e a 265 nm é apresentado para a determinação simultânea de sulfadiazina, sulfametoxipiridazina e sulfametoxazol em amostras de peito de frango. O QuEChERS é barato, rápido e fácil, e a extração dos analitos da matriz foi empregada com sucesso. Além disso, o método apresentou linearidade, na faixa de 25, 50, 100, 150, 175 e 200 µg kg-1, precisão, seletividade e sensibilidade. A precisão intradia (RSD %) para o método QuEChERS foi entre 3,6-10,8 (SDZ), 6,9-14,1 (SPZ) e 1,9-10,9 (SMX) e a precisão interdias (RSD%) foi entre 1,5-9,7, 1,7-4,1 e 2,1-10,1, respectivamente. Resultados de exatidão (tendenciosidade) foram na faixa de -8,6 a +11,9%. Portanto, o método validado é útil para a monitorização de resíduos de medicamentos avaliados em amostras de frangos, bem como todos os valores estavam dentro dos critérios aceitáveis utilizados para a segurança dos alimentos. De seis amostras analisadas, nenhuma apresentou contaminação de sulfonamidas nos níveis detectáveis estudados.
first_indexed 2024-12-21T11:28:07Z
format Article
id doaj.art-2b40c2f002664eb882ae3333695e44e0
institution Directory Open Access Journal
issn 1984-8250
2175-9790
language English
last_indexed 2024-12-21T11:28:07Z
publishDate 2013-03-01
publisher Universidade de São Paulo
record_format Article
series Brazilian Journal of Pharmaceutical Sciences
spelling doaj.art-2b40c2f002664eb882ae3333695e44e02022-12-21T19:05:37ZengUniversidade de São PauloBrazilian Journal of Pharmaceutical Sciences1984-82502175-97902013-03-01491155166QuEChERS-HPLC-DAD method for sulphonamides in chicken breastSimone Caetani MachadoMariane Landin-SilvaPatrícia Penido MaiaSusanne RathIsarita MartinsThe development of a QuEChERS-HPLC-DAD method using a Lichrospher 60 RP-Select B column (250 x 4.6 mm x 5 µm) at 40ºC, mobile phase constituted by phosphate buffer:acetonitrile (75:25, v/v) at a initial flow rate of 0.5 mL min-1, increased by 1.2 mL min-1 and at 265 nm is presented for simultaneous determination of sulphadiazine, sulphametoxipiridazine and sulphamethoxazole in chicken breast samples. QuEchERS is inexpensive, fast and easy, and the extraction of the analytes of the matrix was successfully employed. In addition, the method presented linearity, in the range of 25, 50, 100, 150, 175, and 200 µg kg-1, precision, selectivity and sensitivity. The intraday precision (RSD %) for QuEChERS method was between 3.6-10.8 (SDZ), 6.9-14.1 (SPZ) and 1.9-10.9 (SMX) and interday precision (RSD%) was between 1.5-9.7, 1.7-4.1 and 2.1-10.2, respectively. Results of accuracy (bias) were in the range of -8.6 to +11.9 %. Therefore, the validated method is clearly useful for the practical residue monitoring of the drugs evaluated in chicken samples, as all the values were within the acceptable criteria used for food safety. Of 6 samples analyzed, none of them showed contamination of the sulphonamides studied at detectable levels.<br>O desenvolvimento de um método QuEChERS-HPLC-DAD usando uma coluna Lichrospher RP-60 Select B (250 x 4,6 mm x 5 µm) a 40 ºC, fase móvel constituída por tampão de fosfato: acetonitrila (75:25, v/v) a uma vazão inicial de 0,5 mL min-1, aumentando 1,2 mL min-1 e a 265 nm é apresentado para a determinação simultânea de sulfadiazina, sulfametoxipiridazina e sulfametoxazol em amostras de peito de frango. O QuEChERS é barato, rápido e fácil, e a extração dos analitos da matriz foi empregada com sucesso. Além disso, o método apresentou linearidade, na faixa de 25, 50, 100, 150, 175 e 200 µg kg-1, precisão, seletividade e sensibilidade. A precisão intradia (RSD %) para o método QuEChERS foi entre 3,6-10,8 (SDZ), 6,9-14,1 (SPZ) e 1,9-10,9 (SMX) e a precisão interdias (RSD%) foi entre 1,5-9,7, 1,7-4,1 e 2,1-10,1, respectivamente. Resultados de exatidão (tendenciosidade) foram na faixa de -8,6 a +11,9%. Portanto, o método validado é útil para a monitorização de resíduos de medicamentos avaliados em amostras de frangos, bem como todos os valores estavam dentro dos critérios aceitáveis utilizados para a segurança dos alimentos. De seis amostras analisadas, nenhuma apresentou contaminação de sulfonamidas nos níveis detectáveis estudados.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502013000100017QuEChERSDeterminação de sulfonamidasResíduos de medicamentos veterináriosPeito de frangoHPLC-DADQuEChERSSulphonamides determinationVeterinary drugs residuesChicken breastHPLC-DAD
spellingShingle Simone Caetani Machado
Mariane Landin-Silva
Patrícia Penido Maia
Susanne Rath
Isarita Martins
QuEChERS-HPLC-DAD method for sulphonamides in chicken breast
Brazilian Journal of Pharmaceutical Sciences
QuEChERS
Determinação de sulfonamidas
Resíduos de medicamentos veterinários
Peito de frango
HPLC-DAD
QuEChERS
Sulphonamides determination
Veterinary drugs residues
Chicken breast
HPLC-DAD
title QuEChERS-HPLC-DAD method for sulphonamides in chicken breast
title_full QuEChERS-HPLC-DAD method for sulphonamides in chicken breast
title_fullStr QuEChERS-HPLC-DAD method for sulphonamides in chicken breast
title_full_unstemmed QuEChERS-HPLC-DAD method for sulphonamides in chicken breast
title_short QuEChERS-HPLC-DAD method for sulphonamides in chicken breast
title_sort quechers hplc dad method for sulphonamides in chicken breast
topic QuEChERS
Determinação de sulfonamidas
Resíduos de medicamentos veterinários
Peito de frango
HPLC-DAD
QuEChERS
Sulphonamides determination
Veterinary drugs residues
Chicken breast
HPLC-DAD
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502013000100017
work_keys_str_mv AT simonecaetanimachado quechershplcdadmethodforsulphonamidesinchickenbreast
AT marianelandinsilva quechershplcdadmethodforsulphonamidesinchickenbreast
AT patriciapenidomaia quechershplcdadmethodforsulphonamidesinchickenbreast
AT susannerath quechershplcdadmethodforsulphonamidesinchickenbreast
AT isaritamartins quechershplcdadmethodforsulphonamidesinchickenbreast