Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block

Purpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the re...

Full description

Bibliographic Details
Main Authors: Peter Schuller-Götzburg, Thomas Forte, Werner Pomwenger, Alexander Petutschnigg, Franz Watzinger, Karl Entacher
Format: Article
Language:English
Published: MDPI AG 2018-01-01
Series:Symmetry
Subjects:
Online Access:http://www.mdpi.com/2073-8994/10/2/33
_version_ 1811278904379310080
author Peter Schuller-Götzburg
Thomas Forte
Werner Pomwenger
Alexander Petutschnigg
Franz Watzinger
Karl Entacher
author_facet Peter Schuller-Götzburg
Thomas Forte
Werner Pomwenger
Alexander Petutschnigg
Franz Watzinger
Karl Entacher
author_sort Peter Schuller-Götzburg
collection DOAJ
description Purpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the real geometry based bone models and the simplified geometry models. The bone graft block was placed in three different positions. The implants were loaded first with an axial force and then with forces simulating laterotrusion and protrusion. This study examines whether the calculated stress behavior is symmetrical for both models. Having established a symmetry between the primary axis, the laterotrusion and protrusion behavior reduces calculation efforts, by simplifying the model. Material and Methods: a simplified U-shaped 3D finite element model of the molar region of the upper jaw and a more complex anatomical model of the left maxilla with less cortical bone were created. The bone graft block was placed in the maxillary sinus. Then the von Mises stress distribution was calculated and analyzed at three block positions: at contact with the sinus floor, in the middle of the implant helix and in the upper third of the implant. The two finite element models were then compared to simplify the modelling. Results: the position of the bone graft block significantly influences the magnitude of stress distribution. A bone graft block positioned in the upper third or middle of the implant reduces the quantity of stress compared to the reference model without a bone graft block. The low bone graft block position is clearly associated with lower stress distribution in compact bone. We registered no significant differences in stress in compact bone with regard to laterotrusion or protrusion. Conclusions: maximum values of von Mises stresses in compact bone can be reduced significantly by using a bone graft block. The reduction of stress is nearly the same for positions in the upper third and the middle of the implant. It is much more pronounced when the bone graft block is in the lower third of the implant near the sinus floor, which appeared to be the best position in the present study.
first_indexed 2024-04-13T00:44:05Z
format Article
id doaj.art-2b5ed668ed834c4c8dae0013d7ccfcd8
institution Directory Open Access Journal
issn 2073-8994
language English
last_indexed 2024-04-13T00:44:05Z
publishDate 2018-01-01
publisher MDPI AG
record_format Article
series Symmetry
spelling doaj.art-2b5ed668ed834c4c8dae0013d7ccfcd82022-12-22T03:10:03ZengMDPI AGSymmetry2073-89942018-01-011023310.3390/sym10020033sym10020033Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft BlockPeter Schuller-Götzburg0Thomas Forte1Werner Pomwenger2Alexander Petutschnigg3Franz Watzinger4Karl Entacher5Prosthetics, Biomechanics and Biomaterial Research, Paracelsus Medical University, Strubergasse 21, A-5020 Salzburg, AustriaProsthetics, Biomechanics and Biomaterial Research, Paracelsus Medical University, Strubergasse 21, A-5020 Salzburg, AustriaDepartment of Information Technologies and System Management, Salzburg University of Applied Science, Urstein Süd 1, A-5412 Puch, AustriaDepartment of Forest Products Technology and Wood Construction, Salzburg University of Applied Sciences, Markt 136a, A-5431 Kuchl, AustriaDepartment of Maxillofacial Surgery, Landesklinikum St. Pölten-Lilienfeld, Probst-Führer-Str. 4, A-3100 St. Pölten, AustriaDepartment of Information Technologies and System Management, Salzburg University of Applied Science, Urstein Süd 1, A-5412 Puch, AustriaPurpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the real geometry based bone models and the simplified geometry models. The bone graft block was placed in three different positions. The implants were loaded first with an axial force and then with forces simulating laterotrusion and protrusion. This study examines whether the calculated stress behavior is symmetrical for both models. Having established a symmetry between the primary axis, the laterotrusion and protrusion behavior reduces calculation efforts, by simplifying the model. Material and Methods: a simplified U-shaped 3D finite element model of the molar region of the upper jaw and a more complex anatomical model of the left maxilla with less cortical bone were created. The bone graft block was placed in the maxillary sinus. Then the von Mises stress distribution was calculated and analyzed at three block positions: at contact with the sinus floor, in the middle of the implant helix and in the upper third of the implant. The two finite element models were then compared to simplify the modelling. Results: the position of the bone graft block significantly influences the magnitude of stress distribution. A bone graft block positioned in the upper third or middle of the implant reduces the quantity of stress compared to the reference model without a bone graft block. The low bone graft block position is clearly associated with lower stress distribution in compact bone. We registered no significant differences in stress in compact bone with regard to laterotrusion or protrusion. Conclusions: maximum values of von Mises stresses in compact bone can be reduced significantly by using a bone graft block. The reduction of stress is nearly the same for positions in the upper third and the middle of the implant. It is much more pronounced when the bone graft block is in the lower third of the implant near the sinus floor, which appeared to be the best position in the present study.http://www.mdpi.com/2073-8994/10/2/33sinus liftbone graftingfinite element analysis3D modelingdental implant
spellingShingle Peter Schuller-Götzburg
Thomas Forte
Werner Pomwenger
Alexander Petutschnigg
Franz Watzinger
Karl Entacher
Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block
Symmetry
sinus lift
bone grafting
finite element analysis
3D modeling
dental implant
title Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block
title_full Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block
title_fullStr Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block
title_full_unstemmed Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block
title_short Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block
title_sort three dimensional finite element analysis of maxillary sinus floor augmentation with optimal positioning of a bone graft block
topic sinus lift
bone grafting
finite element analysis
3D modeling
dental implant
url http://www.mdpi.com/2073-8994/10/2/33
work_keys_str_mv AT peterschullergotzburg threedimensionalfiniteelementanalysisofmaxillarysinusflooraugmentationwithoptimalpositioningofabonegraftblock
AT thomasforte threedimensionalfiniteelementanalysisofmaxillarysinusflooraugmentationwithoptimalpositioningofabonegraftblock
AT wernerpomwenger threedimensionalfiniteelementanalysisofmaxillarysinusflooraugmentationwithoptimalpositioningofabonegraftblock
AT alexanderpetutschnigg threedimensionalfiniteelementanalysisofmaxillarysinusflooraugmentationwithoptimalpositioningofabonegraftblock
AT franzwatzinger threedimensionalfiniteelementanalysisofmaxillarysinusflooraugmentationwithoptimalpositioningofabonegraftblock
AT karlentacher threedimensionalfiniteelementanalysisofmaxillarysinusflooraugmentationwithoptimalpositioningofabonegraftblock