Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern Nigeria

Most Nigerian refineries were constructed before pinch technology was developed, hence, the design were not optimal, leading to high energy loss. The objective of this work is to evaluate energy integration of crude distillation unit (CDU) of a refining and petrochemical company in Northern Nigeria...

Full description

Bibliographic Details
Main Authors: U. Hamidu, S. I. Ahmed, U. D. Hamza
Format: Article
Language:English
Published: Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP) 2022-11-01
Series:Journal of Applied Sciences and Environmental Management
Subjects:
Online Access:https://www.ajol.info/index.php/jasem/article/view/237282
_version_ 1797228220051881984
author U. Hamidu
S. I. Ahmed
U. D. Hamza
author_facet U. Hamidu
S. I. Ahmed
U. D. Hamza
author_sort U. Hamidu
collection DOAJ
description Most Nigerian refineries were constructed before pinch technology was developed, hence, the design were not optimal, leading to high energy loss. The objective of this work is to evaluate energy integration of crude distillation unit (CDU) of a refining and petrochemical company in Northern Nigeria using pinch analysis by utilising HINT software. Minimum heating and cooling demand of 32251.1 kW and 29637.9 kW at the pinch point of 506.5 K was evaluated from the composite curve, grand composite curve and the cascade diagram. The region of overlap in the composite curve indicates a total of 108,945 kW as the possible energy that can be recovered in the process. Existing utility demand of the unit was 96,873.5 kW, after heat integration it reduces to 61,889 kW, this showed 36.11 % energy saving with a total operating cost of US$4,560,766.5 that could be saved (annually). Minimum approach temperature (DTmin) analysis results showed an optimum DTmin of 15 K which resulted in a total annual cost of US$6,715,700. Furthermore, the analysis showed the effect of DTmin on energy, area, minimum number of units and cost targets. The design objective of the retrofit heat exchanger network (HEN) was set toward maximum energy recovery. A total of twenty (20) heat exchangers made up the new network, which comprises of twelve (12) process to process heat exchangers, two (2) heaters and six (6) coolers.
first_indexed 2024-04-24T14:53:14Z
format Article
id doaj.art-2b7ecedafa18448db06f2ba38c5a344f
institution Directory Open Access Journal
issn 2659-1502
2659-1499
language English
last_indexed 2024-04-24T14:53:14Z
publishDate 2022-11-01
publisher Joint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)
record_format Article
series Journal of Applied Sciences and Environmental Management
spelling doaj.art-2b7ecedafa18448db06f2ba38c5a344f2024-04-02T19:46:27ZengJoint Coordination Centre of the World Bank assisted National Agricultural Research Programme (NARP)Journal of Applied Sciences and Environmental Management2659-15022659-14992022-11-01261110.4314/jasem.v26i11.11Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern NigeriaU. HamiduS. I. AhmedU. D. Hamza Most Nigerian refineries were constructed before pinch technology was developed, hence, the design were not optimal, leading to high energy loss. The objective of this work is to evaluate energy integration of crude distillation unit (CDU) of a refining and petrochemical company in Northern Nigeria using pinch analysis by utilising HINT software. Minimum heating and cooling demand of 32251.1 kW and 29637.9 kW at the pinch point of 506.5 K was evaluated from the composite curve, grand composite curve and the cascade diagram. The region of overlap in the composite curve indicates a total of 108,945 kW as the possible energy that can be recovered in the process. Existing utility demand of the unit was 96,873.5 kW, after heat integration it reduces to 61,889 kW, this showed 36.11 % energy saving with a total operating cost of US$4,560,766.5 that could be saved (annually). Minimum approach temperature (DTmin) analysis results showed an optimum DTmin of 15 K which resulted in a total annual cost of US$6,715,700. Furthermore, the analysis showed the effect of DTmin on energy, area, minimum number of units and cost targets. The design objective of the retrofit heat exchanger network (HEN) was set toward maximum energy recovery. A total of twenty (20) heat exchangers made up the new network, which comprises of twelve (12) process to process heat exchangers, two (2) heaters and six (6) coolers. https://www.ajol.info/index.php/jasem/article/view/237282Cost;Crude Distillation;Energy integration;Heat Exchangers;Pinch analysis
spellingShingle U. Hamidu
S. I. Ahmed
U. D. Hamza
Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern Nigeria
Journal of Applied Sciences and Environmental Management
Cost;
Crude Distillation;
Energy integration;
Heat Exchangers;
Pinch analysis
title Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern Nigeria
title_full Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern Nigeria
title_fullStr Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern Nigeria
title_full_unstemmed Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern Nigeria
title_short Energy Integration of Crude Distillation Unit of a Refining and Petrochemical Company in Northern Nigeria
title_sort energy integration of crude distillation unit of a refining and petrochemical company in northern nigeria
topic Cost;
Crude Distillation;
Energy integration;
Heat Exchangers;
Pinch analysis
url https://www.ajol.info/index.php/jasem/article/view/237282
work_keys_str_mv AT uhamidu energyintegrationofcrudedistillationunitofarefiningandpetrochemicalcompanyinnorthernnigeria
AT siahmed energyintegrationofcrudedistillationunitofarefiningandpetrochemicalcompanyinnorthernnigeria
AT udhamza energyintegrationofcrudedistillationunitofarefiningandpetrochemicalcompanyinnorthernnigeria