Failure of dual radius hydroxyapatite-coated acetabular cups

<p>Abstract</p> <p>Introduction</p> <p>Many kind of hydroxyapatite-coated cups were used, with favorable results in short term studies; it was supposed that its use could improve osteointegration of the cup, enhancing thus stability and survivorship. The purpose of this...

Full description

Bibliographic Details
Main Authors: Zatti Giovanni, Riva Giacomo, Molina Mauro, D'Angelo Fabio, Cherubino Paolo
Format: Article
Language:English
Published: BMC 2008-08-01
Series:Journal of Orthopaedic Surgery and Research
Online Access:http://www.josr-online.com/content/3/1/35
_version_ 1817995655326466048
author Zatti Giovanni
Riva Giacomo
Molina Mauro
D'Angelo Fabio
Cherubino Paolo
author_facet Zatti Giovanni
Riva Giacomo
Molina Mauro
D'Angelo Fabio
Cherubino Paolo
author_sort Zatti Giovanni
collection DOAJ
description <p>Abstract</p> <p>Introduction</p> <p>Many kind of hydroxyapatite-coated cups were used, with favorable results in short term studies; it was supposed that its use could improve osteointegration of the cup, enhancing thus stability and survivorship. The purpose of this study is to analyze the long term behavior of the hemispheric HA coated, Dual Radius Osteonics cup and to discuss the way of failure through the exam of the revised components and of both periacetabular and osteolysis tissue.</p> <p>Materials and Methods</p> <p>Between 1994 and 1997, at the Department of Orthopedic Sciences of the Insubria University, using the posterolateral approach, were implanted 276 Dual Radius Osteonics<sup>® </sup>in 256 patients, with mean age of 63 years.</p> <p>Results</p> <p>At a mean follow-up of 10 years (range 8–12 years), 183 cups in 165 patients, were available for clinical and radiographical evaluation. 22 Cups among the 183 were revised (11%). The cause of revision was aseptic loosening in 17 cases, septic loosening in one case, periprosthetic fracture in another case, osteolysis and polyethylene wear in two cases and, finally, recurrent dislocations in the last one. In the remaining patients, mean HHS increased from a preoperative value of 50,15 to a postoperative value of 92,69. The mean polyethylene wear was 1,25 mm (min. 0,08, max. 3,9 mm), with a mean annual wear of 0,17 mm. The mean acetabular migration on the two axis was 1,6 mm and 1,8 mm. Peri-acetabular osteolysis were recorded in 89% of the implants (163 cases). The cumulative survivorship (revision as endpoint) at the time was 88,9%.</p> <p>Conclusion</p> <p>Our study confirms the bad behavior of this type of cup probably related to the design, to the method of HA fixation. The observations carried out on the revised cup confirm these hypotheses but did not clarify if the third body wear could be a further problem. Another interesting aspect is the high incidence of osteolysis, which are often asymptomatic becoming a problem for the surgeon as the patient refuses the possibility of a revision.</p>
first_indexed 2024-04-14T02:10:08Z
format Article
id doaj.art-2b8d154778b7403b9499311273dc5c2c
institution Directory Open Access Journal
issn 1749-799X
language English
last_indexed 2024-04-14T02:10:08Z
publishDate 2008-08-01
publisher BMC
record_format Article
series Journal of Orthopaedic Surgery and Research
spelling doaj.art-2b8d154778b7403b9499311273dc5c2c2022-12-22T02:18:28ZengBMCJournal of Orthopaedic Surgery and Research1749-799X2008-08-01313510.1186/1749-799X-3-35Failure of dual radius hydroxyapatite-coated acetabular cupsZatti GiovanniRiva GiacomoMolina MauroD'Angelo FabioCherubino Paolo<p>Abstract</p> <p>Introduction</p> <p>Many kind of hydroxyapatite-coated cups were used, with favorable results in short term studies; it was supposed that its use could improve osteointegration of the cup, enhancing thus stability and survivorship. The purpose of this study is to analyze the long term behavior of the hemispheric HA coated, Dual Radius Osteonics cup and to discuss the way of failure through the exam of the revised components and of both periacetabular and osteolysis tissue.</p> <p>Materials and Methods</p> <p>Between 1994 and 1997, at the Department of Orthopedic Sciences of the Insubria University, using the posterolateral approach, were implanted 276 Dual Radius Osteonics<sup>® </sup>in 256 patients, with mean age of 63 years.</p> <p>Results</p> <p>At a mean follow-up of 10 years (range 8–12 years), 183 cups in 165 patients, were available for clinical and radiographical evaluation. 22 Cups among the 183 were revised (11%). The cause of revision was aseptic loosening in 17 cases, septic loosening in one case, periprosthetic fracture in another case, osteolysis and polyethylene wear in two cases and, finally, recurrent dislocations in the last one. In the remaining patients, mean HHS increased from a preoperative value of 50,15 to a postoperative value of 92,69. The mean polyethylene wear was 1,25 mm (min. 0,08, max. 3,9 mm), with a mean annual wear of 0,17 mm. The mean acetabular migration on the two axis was 1,6 mm and 1,8 mm. Peri-acetabular osteolysis were recorded in 89% of the implants (163 cases). The cumulative survivorship (revision as endpoint) at the time was 88,9%.</p> <p>Conclusion</p> <p>Our study confirms the bad behavior of this type of cup probably related to the design, to the method of HA fixation. The observations carried out on the revised cup confirm these hypotheses but did not clarify if the third body wear could be a further problem. Another interesting aspect is the high incidence of osteolysis, which are often asymptomatic becoming a problem for the surgeon as the patient refuses the possibility of a revision.</p>http://www.josr-online.com/content/3/1/35
spellingShingle Zatti Giovanni
Riva Giacomo
Molina Mauro
D'Angelo Fabio
Cherubino Paolo
Failure of dual radius hydroxyapatite-coated acetabular cups
Journal of Orthopaedic Surgery and Research
title Failure of dual radius hydroxyapatite-coated acetabular cups
title_full Failure of dual radius hydroxyapatite-coated acetabular cups
title_fullStr Failure of dual radius hydroxyapatite-coated acetabular cups
title_full_unstemmed Failure of dual radius hydroxyapatite-coated acetabular cups
title_short Failure of dual radius hydroxyapatite-coated acetabular cups
title_sort failure of dual radius hydroxyapatite coated acetabular cups
url http://www.josr-online.com/content/3/1/35
work_keys_str_mv AT zattigiovanni failureofdualradiushydroxyapatitecoatedacetabularcups
AT rivagiacomo failureofdualradiushydroxyapatitecoatedacetabularcups
AT molinamauro failureofdualradiushydroxyapatitecoatedacetabularcups
AT dangelofabio failureofdualradiushydroxyapatitecoatedacetabularcups
AT cherubinopaolo failureofdualradiushydroxyapatitecoatedacetabularcups