Synthesis and Characterization of Ru-MOFs on Microelectrode for Trace Mercury Detection

Mercury ions (Hg<inline-formula><math display="inline"><semantics><msup><mrow></mrow><mrow><mn>2</mn><mo>+</mo></mrow></msup></semantics></math></inline-formula>) pollution in the water environm...

Full description

Bibliographic Details
Main Authors: Chenyu Xiong, Yuhao Xu, Chao Bian, Ri Wang, Yong Xie, Mingjie Han, Shanhong Xia
Format: Article
Language:English
Published: MDPI AG 2020-11-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/22/6686
Description
Summary:Mercury ions (Hg<inline-formula><math display="inline"><semantics><msup><mrow></mrow><mrow><mn>2</mn><mo>+</mo></mrow></msup></semantics></math></inline-formula>) pollution in the water environment can cause serious harm to human health. Trace Hg<inline-formula><math display="inline"><semantics><msup><mrow></mrow><mrow><mn>2</mn><mo>+</mo></mrow></msup></semantics></math></inline-formula> detection is of vital importance for environmental monitoring. Herein, we report a novel design of Ru-MOFs modified gold microelectrode for Hg<inline-formula><math display="inline"><semantics><msup><mrow></mrow><mrow><mn>2</mn><mo>+</mo></mrow></msup></semantics></math></inline-formula> determination. Ru-MOFs are synthesized directly by the cathodic method on gold microelectrode, with the covered area accurately controlled. Cathodic synthesized Ru-MOFs show good conductivity and are suitable to be used as the electrode surface material directly. The synergy of the pre-deposition process and the adsorption process of Ru-MOFs can effectively improves the performance of the sensor. The results show good linearity (R<inline-formula><math display="inline"><semantics><msup><mrow></mrow><mn>2</mn></msup></semantics></math></inline-formula> = 0.996) from 0.1 ppb to 5 ppb, with a high sensitivity of 0.583 <inline-formula><math display="inline"><semantics><mi mathvariant="sans-serif">μ</mi></semantics></math></inline-formula>A ppb<inline-formula><math display="inline"><semantics><msup><mrow></mrow><mrow><mo>−</mo><mn>1</mn></mrow></msup></semantics></math></inline-formula> mm<inline-formula><math display="inline"><semantics><msup><mrow></mrow><mrow><mo>−</mo><mn>2</mn></mrow></msup></semantics></math></inline-formula>. The limit of detection is found to be 0.08 ppb and the test process is within 6 min. Most importantly, the senor has a good anti-interference ability and the recoveries are satisfactory. This miniature electrochemical sensor has the potential for on-site detection of trace mercury in the field.
ISSN:1424-8220