Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy Logic
The incidence of poisoning due to carbon monoxide gas arising from drilling activities on the first floor of a building in the Kelapa Gading beauty clinic in Jakarta resulted in 17 people experiencing poisoning. In this study developing a device on the sensor used to detect CO and SO2 gas, in the ai...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2019-01-01
|
Series: | E3S Web of Conferences |
Subjects: | |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/51/e3sconf_icenis2019_23013.pdf |
_version_ | 1828902335006375936 |
---|---|
author | Widodo Slamet Amin M.Miftakhul Supani Ahyar |
author_facet | Widodo Slamet Amin M.Miftakhul Supani Ahyar |
author_sort | Widodo Slamet |
collection | DOAJ |
description | The incidence of poisoning due to carbon monoxide gas arising from drilling activities on the first floor of a building in the Kelapa Gading beauty clinic in Jakarta resulted in 17 people experiencing poisoning. In this study developing a device on the sensor used to detect CO and SO2 gas, in the air of a closed room using gas sensor MQ 135 and MQ 136. The results of testing the CO and SO2 gas gauges using samples of cigarette smoke and sulfur powder using MQ 135 and MQ 136 sensors with fuzzy rule base logic for motor speed to produce CO and SO2 gas, that obtained a value of 0.233 ppm SO2 gas safe conditions and gas input CO with the sensor obtained a value of 0.513 ppm, the condition is safe so that the output is 49.8 ppm, the condition of the fan blower does not rotate. Whereas when the reading value of 5.0 ppm is very concentrated and the CO gas input with the sensor is 13.8 ppm the condition is very concentrated producing an output of 228 ppm the very danger. |
first_indexed | 2024-12-13T16:14:50Z |
format | Article |
id | doaj.art-2bb2d48cf1484f8a8761d2977b843a08 |
institution | Directory Open Access Journal |
issn | 2267-1242 |
language | English |
last_indexed | 2024-12-13T16:14:50Z |
publishDate | 2019-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | E3S Web of Conferences |
spelling | doaj.art-2bb2d48cf1484f8a8761d2977b843a082022-12-21T23:38:51ZengEDP SciencesE3S Web of Conferences2267-12422019-01-011252301310.1051/e3sconf/201912523013e3sconf_icenis2019_23013Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy LogicWidodo Slamet0Amin M.Miftakhul1Supani Ahyar2Departmen of Computer Engineering Politeknik Sriwijaya, Jalan Srijaya Negera, Bukit BesarDepartmen of Computer Engineering Politeknik Sriwijaya, Jalan Srijaya Negera, Bukit BesarDepartmen of Computer Engineering Politeknik Sriwijaya, Jalan Srijaya Negera, Bukit BesarThe incidence of poisoning due to carbon monoxide gas arising from drilling activities on the first floor of a building in the Kelapa Gading beauty clinic in Jakarta resulted in 17 people experiencing poisoning. In this study developing a device on the sensor used to detect CO and SO2 gas, in the air of a closed room using gas sensor MQ 135 and MQ 136. The results of testing the CO and SO2 gas gauges using samples of cigarette smoke and sulfur powder using MQ 135 and MQ 136 sensors with fuzzy rule base logic for motor speed to produce CO and SO2 gas, that obtained a value of 0.233 ppm SO2 gas safe conditions and gas input CO with the sensor obtained a value of 0.513 ppm, the condition is safe so that the output is 49.8 ppm, the condition of the fan blower does not rotate. Whereas when the reading value of 5.0 ppm is very concentrated and the CO gas input with the sensor is 13.8 ppm the condition is very concentrated producing an output of 228 ppm the very danger.https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/51/e3sconf_icenis2019_23013.pdfgas sensors mq 136fuzzy logicgas co and so2 |
spellingShingle | Widodo Slamet Amin M.Miftakhul Supani Ahyar Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy Logic E3S Web of Conferences gas sensors mq 136 fuzzy logic gas co and so2 |
title | Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy Logic |
title_full | Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy Logic |
title_fullStr | Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy Logic |
title_full_unstemmed | Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy Logic |
title_short | Design of Indoor Room Gas CO and SO2 Detection Based on Microcontroller Using Fuzzy Logic |
title_sort | design of indoor room gas co and so2 detection based on microcontroller using fuzzy logic |
topic | gas sensors mq 136 fuzzy logic gas co and so2 |
url | https://www.e3s-conferences.org/articles/e3sconf/pdf/2019/51/e3sconf_icenis2019_23013.pdf |
work_keys_str_mv | AT widodoslamet designofindoorroomgascoandso2detectionbasedonmicrocontrollerusingfuzzylogic AT aminmmiftakhul designofindoorroomgascoandso2detectionbasedonmicrocontrollerusingfuzzylogic AT supaniahyar designofindoorroomgascoandso2detectionbasedonmicrocontrollerusingfuzzylogic |