Designing a Local Exhaust Ventilation System to Control Toluene Diisocyanate and Dust in Woodworking Industries
Spreading wood particles and attached colored materials in workplaces can cause many problems for woodworking industry workers. The aim of this study was to design and implement a local exhaust ventilation system to control wood dust and toluene diisocyanate simultaneously. The study was conducted o...
Main Authors: | MEHRDAD HELMI KOHNESHAHRI, MAHMOUD MOHAMMADYAN, HOMA MALECK KHANI, MEHRAN POURHOSSEIN, BAHMAN DASTAKZAN |
---|---|
Format: | Article |
Language: | English |
Published: |
Tehran University of Medical Sciences
2017-04-01
|
Series: | International Journal of Occupational Hygiene |
Subjects: | |
Online Access: | https://ijoh.tums.ac.ir/index.php/ijoh/article/view/250 |