Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses

Purpose: To compare the visual outcomes and monocular defocus curve of a new monofocal Tecnis Eyhance IOL (Tecnis ICB00) with Tecnis 1 single piece (ZCB00). Methods: Eighty patients diagnosed with cataract were divided into two groups: Tecnis ICB00 (n = 40) and ZCB00 (n = 40). The visual outcome was...

Full description

Bibliographic Details
Main Authors: Gagandeep Singh, K S Sidhharthan, Jagadeesh K Reddy, Vandana Sundaram, Mithun Thulasidas
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2024-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2024;volume=72;issue=2;spage=181;epage=184;aulast=Singh
_version_ 1797225806245658624
author Gagandeep Singh
K S Sidhharthan
Jagadeesh K Reddy
Vandana Sundaram
Mithun Thulasidas
author_facet Gagandeep Singh
K S Sidhharthan
Jagadeesh K Reddy
Vandana Sundaram
Mithun Thulasidas
author_sort Gagandeep Singh
collection DOAJ
description Purpose: To compare the visual outcomes and monocular defocus curve of a new monofocal Tecnis Eyhance IOL (Tecnis ICB00) with Tecnis 1 single piece (ZCB00). Methods: Eighty patients diagnosed with cataract were divided into two groups: Tecnis ICB00 (n = 40) and ZCB00 (n = 40). The visual outcome was evaluated using the following parameters: uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity (DCIVA), corrected near visual acuity (CNVA), uncorrected visual acuity contrast sensitivity (UVACS), best-corrected visual acuity contrast sensitivity (BCVACS), manifest refraction, and defocus curve and was compared at the 6th week and 3 months after surgery. Results: The UIVA and UNVA were significantly (P < 0.05) better in ICB00 as compared with ZCB00 at 6 weeks and 3 months postoperative. The DCIVA was significantly better in ICB00 as compared with ZCB00 at 3 months postoperative (−0.015 ± 0.04 vs. 0.01 ± 0.020; P = 0.01). Regarding contrast sensitivity, UVACS and BCVACS were significantly better in ICB00 as compared with ZCB00 at 6 weeks and 3 months postoperative (P < 0.05). The defocus curves showed that the mean visual acuity of the ICB00 group was significantly better than that of the ZCB00 group at between – 0.5 D and – 2.50 D of defocus. Conclusion: In patients undergoing cataract surgery, Eyhance ICB00 provided better intermediate vision as compared with ZCB00.
first_indexed 2024-04-24T14:14:52Z
format Article
id doaj.art-2c2d51e72a544682bd8c100c6fef0fa5
institution Directory Open Access Journal
issn 0301-4738
1998-3689
language English
last_indexed 2024-04-24T14:14:52Z
publishDate 2024-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Ophthalmology
spelling doaj.art-2c2d51e72a544682bd8c100c6fef0fa52024-04-03T08:54:28ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892024-01-0172218118410.4103/IJO.IJO_681_23Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lensesGagandeep SinghK S SidhharthanJagadeesh K ReddyVandana SundaramMithun ThulasidasPurpose: To compare the visual outcomes and monocular defocus curve of a new monofocal Tecnis Eyhance IOL (Tecnis ICB00) with Tecnis 1 single piece (ZCB00). Methods: Eighty patients diagnosed with cataract were divided into two groups: Tecnis ICB00 (n = 40) and ZCB00 (n = 40). The visual outcome was evaluated using the following parameters: uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity (DCIVA), corrected near visual acuity (CNVA), uncorrected visual acuity contrast sensitivity (UVACS), best-corrected visual acuity contrast sensitivity (BCVACS), manifest refraction, and defocus curve and was compared at the 6th week and 3 months after surgery. Results: The UIVA and UNVA were significantly (P < 0.05) better in ICB00 as compared with ZCB00 at 6 weeks and 3 months postoperative. The DCIVA was significantly better in ICB00 as compared with ZCB00 at 3 months postoperative (−0.015 ± 0.04 vs. 0.01 ± 0.020; P = 0.01). Regarding contrast sensitivity, UVACS and BCVACS were significantly better in ICB00 as compared with ZCB00 at 6 weeks and 3 months postoperative (P < 0.05). The defocus curves showed that the mean visual acuity of the ICB00 group was significantly better than that of the ZCB00 group at between – 0.5 D and – 2.50 D of defocus. Conclusion: In patients undergoing cataract surgery, Eyhance ICB00 provided better intermediate vision as compared with ZCB00.http://www.ijo.in/article.asp?issn=0301-4738;year=2024;volume=72;issue=2;spage=181;epage=184;aulast=Singhcataract surgerydefocus curveeyhance icb00visual outcomeszcb00
spellingShingle Gagandeep Singh
K S Sidhharthan
Jagadeesh K Reddy
Vandana Sundaram
Mithun Thulasidas
Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses
Indian Journal of Ophthalmology
cataract surgery
defocus curve
eyhance icb00
visual outcomes
zcb00
title Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses
title_full Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses
title_fullStr Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses
title_full_unstemmed Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses
title_short Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses
title_sort comparison of visual outcomes in patients implanted with tecnis eyhance icb00 and 1 piece zcb00 monofocal intraocular lenses
topic cataract surgery
defocus curve
eyhance icb00
visual outcomes
zcb00
url http://www.ijo.in/article.asp?issn=0301-4738;year=2024;volume=72;issue=2;spage=181;epage=184;aulast=Singh
work_keys_str_mv AT gagandeepsingh comparisonofvisualoutcomesinpatientsimplantedwithtecniseyhanceicb00and1piecezcb00monofocalintraocularlenses
AT kssidhharthan comparisonofvisualoutcomesinpatientsimplantedwithtecniseyhanceicb00and1piecezcb00monofocalintraocularlenses
AT jagadeeshkreddy comparisonofvisualoutcomesinpatientsimplantedwithtecniseyhanceicb00and1piecezcb00monofocalintraocularlenses
AT vandanasundaram comparisonofvisualoutcomesinpatientsimplantedwithtecniseyhanceicb00and1piecezcb00monofocalintraocularlenses
AT mithunthulasidas comparisonofvisualoutcomesinpatientsimplantedwithtecniseyhanceicb00and1piecezcb00monofocalintraocularlenses