Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery

Background. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO-implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL-V4c implantation. Preoperative vault pred...

Full description

Bibliographic Details
Main Authors: Xin Zhong, Yan Li, Yuancun Li, Geng Wang, Yali Du, Mingzhi Zhang
Format: Article
Language:English
Published: Hindawi Limited 2024-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2024/4256371
_version_ 1827009485194919936
author Xin Zhong
Yan Li
Yuancun Li
Geng Wang
Yali Du
Mingzhi Zhang
author_facet Xin Zhong
Yan Li
Yuancun Li
Geng Wang
Yali Du
Mingzhi Zhang
author_sort Xin Zhong
collection DOAJ
description Background. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO-implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL-V4c implantation. Preoperative vault prediction was conducted by utilizing the NK and KS formulas, with postoperative measurements by anterior segment optical coherence tomography (AS-OCT) at one month. The analysis focused on the consistency between predicted and achieved vaults, as well as the correlation between the achieved vault and various biometric parameters. Results. The mean achieved vault was 605.25 ± 212.72 µm, which was significantly smaller than the predicted vaults of 710.08 ± 195.08 and 673.80 ± 212.76 µm, using the NK and KS formulas, respectively (P<0.05). The mean differences between the achieved vault and the predicted vault using the NK formula and KS formula were −104.82 μm (95% LoA: −600.38–391.19 μm) and −68.55 μm (95% LoA: −628.91–491.82 μm), respectively. Anterior chamber depth (ACD), vertical sulcus-to-sulcus (V-STS) diameter, and crystalline lens rise (CLR) were independent factors associated with the achieved vault (P<0.05). The two formulas showed no statistically significant difference in absolute prediction error (APE). Conclusion. The NK formula exhibited superior consistency and low predictive error compared to the KS formula in the 12.6 mm ICL group. AS-OCT measurements overestimated the predicted ICL vault, especially in the 13.2 mm ICL size selection. Relying solely on the NK or KS formulas for predicting vaults before ICL surgery is not recommended.
first_indexed 2025-02-18T12:49:19Z
format Article
id doaj.art-2c931685dab74637a9f5a5dbaee9b050
institution Directory Open Access Journal
issn 2090-0058
language English
last_indexed 2025-02-18T12:49:19Z
publishDate 2024-01-01
publisher Hindawi Limited
record_format Article
series Journal of Ophthalmology
spelling doaj.art-2c931685dab74637a9f5a5dbaee9b0502024-11-02T03:58:43ZengHindawi LimitedJournal of Ophthalmology2090-00582024-01-01202410.1155/2024/4256371Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens SurgeryXin Zhong0Yan Li1Yuancun Li2Geng Wang3Yali Du4Mingzhi Zhang5Joint Shantou International Eye Center of Shantou UniversityJoint Shantou International Eye Center of Shantou UniversityJoint Shantou International Eye Center of Shantou UniversityJoint Shantou International Eye Center of Shantou UniversityJoint Shantou International Eye Center of Shantou UniversityJoint Shantou International Eye Center of Shantou UniversityBackground. This study aims to investigate the agreement between the NK and KS formulas in predicting the vault after implantation of an EVO-implantable collamer lens (ICL). Methods. This retrospective study included 106 eyes of 57 patients who underwent ICL-V4c implantation. Preoperative vault prediction was conducted by utilizing the NK and KS formulas, with postoperative measurements by anterior segment optical coherence tomography (AS-OCT) at one month. The analysis focused on the consistency between predicted and achieved vaults, as well as the correlation between the achieved vault and various biometric parameters. Results. The mean achieved vault was 605.25 ± 212.72 µm, which was significantly smaller than the predicted vaults of 710.08 ± 195.08 and 673.80 ± 212.76 µm, using the NK and KS formulas, respectively (P<0.05). The mean differences between the achieved vault and the predicted vault using the NK formula and KS formula were −104.82 μm (95% LoA: −600.38–391.19 μm) and −68.55 μm (95% LoA: −628.91–491.82 μm), respectively. Anterior chamber depth (ACD), vertical sulcus-to-sulcus (V-STS) diameter, and crystalline lens rise (CLR) were independent factors associated with the achieved vault (P<0.05). The two formulas showed no statistically significant difference in absolute prediction error (APE). Conclusion. The NK formula exhibited superior consistency and low predictive error compared to the KS formula in the 12.6 mm ICL group. AS-OCT measurements overestimated the predicted ICL vault, especially in the 13.2 mm ICL size selection. Relying solely on the NK or KS formulas for predicting vaults before ICL surgery is not recommended.http://dx.doi.org/10.1155/2024/4256371
spellingShingle Xin Zhong
Yan Li
Yuancun Li
Geng Wang
Yali Du
Mingzhi Zhang
Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
Journal of Ophthalmology
title Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
title_full Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
title_fullStr Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
title_full_unstemmed Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
title_short Comparison of Predictability in Vault Using NK Formula and KS Formula for the Implantable Collamer Lens Surgery
title_sort comparison of predictability in vault using nk formula and ks formula for the implantable collamer lens surgery
url http://dx.doi.org/10.1155/2024/4256371
work_keys_str_mv AT xinzhong comparisonofpredictabilityinvaultusingnkformulaandksformulafortheimplantablecollamerlenssurgery
AT yanli comparisonofpredictabilityinvaultusingnkformulaandksformulafortheimplantablecollamerlenssurgery
AT yuancunli comparisonofpredictabilityinvaultusingnkformulaandksformulafortheimplantablecollamerlenssurgery
AT gengwang comparisonofpredictabilityinvaultusingnkformulaandksformulafortheimplantablecollamerlenssurgery
AT yalidu comparisonofpredictabilityinvaultusingnkformulaandksformulafortheimplantablecollamerlenssurgery
AT mingzhizhang comparisonofpredictabilityinvaultusingnkformulaandksformulafortheimplantablecollamerlenssurgery