OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICES

The paper deals with creation of optical deflector for management of laser radiation in physiotherapeutic devices. Design features and operation principles of electro-optical, optical-acoustic and mechanical deflectors, giving the possibility to carry out continuous or discrete scanning of a laser b...

Full description

Bibliographic Details
Main Authors: V. N. Baranov, A. S. Kachalin, M. S. Bochkov
Format: Article
Language:English
Published: Saint Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO University) 2014-03-01
Series:Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki
Subjects:
Online Access:http://ntv.ifmo.ru/file/article/9371.pdf
_version_ 1819142034177392640
author V. N. Baranov
A. S. Kachalin
M. S. Bochkov
author_facet V. N. Baranov
A. S. Kachalin
M. S. Bochkov
author_sort V. N. Baranov
collection DOAJ
description The paper deals with creation of optical deflector for management of laser radiation in physiotherapeutic devices. Design features and operation principles of electro-optical, optical-acoustic and mechanical deflectors, giving the possibility to carry out continuous or discrete scanning of a laser beam are shown. Operation mechanism of the mechanical type deflector on the example of domestic laser therapeutic scanners is described in detail. Application possibility in clinical practice for heating technique of the acupuncture points by volumetric scanning of tissues by the radiation of semiconductor lasers on wave lengths equal to 0,67 and 0,85 μm is investigated. Creation justification of the new type deflector is given. Comparison between stable and labile techniques of radiation is carried out. It is shown that more intensive warming up of a skin surface in acupuncture point projection is observed at volumetric scanning, rather than at planar scanning by laser beams. Temperature increase on a skin surface in projection of acupuncture points is detected at radiation in both the visible spectrum range (0,67 μm) and the infrared range (0,85 μm). It gives the possibility to apply this scanning method to thermal photo-activation of the point and to extend an existing arsenal of laser reflexology methods. The optical deflector is offered for medical industry, making it possible to carry out volumetric scanning of a laser beam and to facilitate the medical personnel’s work in laser therapy and reflexology consulting rooms.
first_indexed 2024-12-22T12:03:55Z
format Article
id doaj.art-2d11bf1c4bb1414c846134d090713166
institution Directory Open Access Journal
issn 2226-1494
2500-0373
language English
last_indexed 2024-12-22T12:03:55Z
publishDate 2014-03-01
publisher Saint Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO University)
record_format Article
series Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki
spelling doaj.art-2d11bf1c4bb1414c846134d0907131662022-12-21T18:26:29ZengSaint Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO University)Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki2226-14942500-03732014-03-011423238OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICESV. N. BaranovA. S. KachalinM. S. BochkovThe paper deals with creation of optical deflector for management of laser radiation in physiotherapeutic devices. Design features and operation principles of electro-optical, optical-acoustic and mechanical deflectors, giving the possibility to carry out continuous or discrete scanning of a laser beam are shown. Operation mechanism of the mechanical type deflector on the example of domestic laser therapeutic scanners is described in detail. Application possibility in clinical practice for heating technique of the acupuncture points by volumetric scanning of tissues by the radiation of semiconductor lasers on wave lengths equal to 0,67 and 0,85 μm is investigated. Creation justification of the new type deflector is given. Comparison between stable and labile techniques of radiation is carried out. It is shown that more intensive warming up of a skin surface in acupuncture point projection is observed at volumetric scanning, rather than at planar scanning by laser beams. Temperature increase on a skin surface in projection of acupuncture points is detected at radiation in both the visible spectrum range (0,67 μm) and the infrared range (0,85 μm). It gives the possibility to apply this scanning method to thermal photo-activation of the point and to extend an existing arsenal of laser reflexology methods. The optical deflector is offered for medical industry, making it possible to carry out volumetric scanning of a laser beam and to facilitate the medical personnel’s work in laser therapy and reflexology consulting rooms.http://ntv.ifmo.ru/file/article/9371.pdflasersoptical deflectorsradiation managementlaser therapylaser reflexology
spellingShingle V. N. Baranov
A. S. Kachalin
M. S. Bochkov
OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICES
Naučno-tehničeskij Vestnik Informacionnyh Tehnologij, Mehaniki i Optiki
lasers
optical deflectors
radiation management
laser therapy
laser reflexology
title OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICES
title_full OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICES
title_fullStr OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICES
title_full_unstemmed OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICES
title_short OPTICAL DEFLECTOR CREATION FOR LASER THERAPEUTIC DEVICES
title_sort optical deflector creation for laser therapeutic devices
topic lasers
optical deflectors
radiation management
laser therapy
laser reflexology
url http://ntv.ifmo.ru/file/article/9371.pdf
work_keys_str_mv AT vnbaranov opticaldeflectorcreationforlasertherapeuticdevices
AT askachalin opticaldeflectorcreationforlasertherapeuticdevices
AT msbochkov opticaldeflectorcreationforlasertherapeuticdevices