Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold Weather

As train failures from icicles annually recur in old railway tunnels in cold weather, fundamental measures to prevent the formation of icicles within the tunnels are necessary for the safe operation of trains and efficient maintenance of old tunnels. This study develops and tests a thawing-guided dr...

Full description

Bibliographic Details
Main Authors: Sangjoon Kang, Taehoon Koh, Hanju Yoo
Format: Article
Language:English
Published: MDPI AG 2022-11-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/12/22/11645
_version_ 1797465965173145600
author Sangjoon Kang
Taehoon Koh
Hanju Yoo
author_facet Sangjoon Kang
Taehoon Koh
Hanju Yoo
author_sort Sangjoon Kang
collection DOAJ
description As train failures from icicles annually recur in old railway tunnels in cold weather, fundamental measures to prevent the formation of icicles within the tunnels are necessary for the safe operation of trains and efficient maintenance of old tunnels. This study develops and tests a thawing-guided drainage system for old railway tunnels. The proposed system consists of heating panels, supporting stands, and the drainageways for discharging leaked water. A heating panel is composed of a film heater, thermal insulator, and a steel plate. The heater installed on a steel plate supplies the heat source to prevent icicle formation. This system uses a low-power module lining structure, which fundamentally prevents the formation of icicles from cracks in old railway tunnels and induces the drainage of thermally melted icicles to the outside of the track. A prototype system was installed in the Seungbu tunnel (a railway tunnel) and monitored over 3 weeks in winter from 22 December 2021 to 12 January 2022. The icicle prevention and guided drainage performances were verified at an ambient temperature of about −10 °C, with an internal temperature for maintaining the system above 0 °C over the whole test period. The proposed system is judged by the fact that the applicability of the developed system has been verified in consideration of the following three aspects: usability in the operational railway line, effectiveness through icicle prevention performance, and operational safety which does not interfere with train operations.
first_indexed 2024-03-09T18:29:06Z
format Article
id doaj.art-2d5574d15bea4de8bd52522b0709ab37
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-09T18:29:06Z
publishDate 2022-11-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-2d5574d15bea4de8bd52522b0709ab372023-11-24T07:38:36ZengMDPI AGApplied Sciences2076-34172022-11-0112221164510.3390/app122211645Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold WeatherSangjoon Kang0Taehoon Koh1Hanju Yoo2Track and Trackbed Research Department, Korea Railroad Research Institute, 176 Chuldobangmulgwan-ro, Uiwang-si 16105, Gyeonggi-do, Republic of KoreaTrack and Trackbed Research Department, Korea Railroad Research Institute, 176 Chuldobangmulgwan-ro, Uiwang-si 16105, Gyeonggi-do, Republic of KoreaTrack and Trackbed Research Department, Korea Railroad Research Institute, 176 Chuldobangmulgwan-ro, Uiwang-si 16105, Gyeonggi-do, Republic of KoreaAs train failures from icicles annually recur in old railway tunnels in cold weather, fundamental measures to prevent the formation of icicles within the tunnels are necessary for the safe operation of trains and efficient maintenance of old tunnels. This study develops and tests a thawing-guided drainage system for old railway tunnels. The proposed system consists of heating panels, supporting stands, and the drainageways for discharging leaked water. A heating panel is composed of a film heater, thermal insulator, and a steel plate. The heater installed on a steel plate supplies the heat source to prevent icicle formation. This system uses a low-power module lining structure, which fundamentally prevents the formation of icicles from cracks in old railway tunnels and induces the drainage of thermally melted icicles to the outside of the track. A prototype system was installed in the Seungbu tunnel (a railway tunnel) and monitored over 3 weeks in winter from 22 December 2021 to 12 January 2022. The icicle prevention and guided drainage performances were verified at an ambient temperature of about −10 °C, with an internal temperature for maintaining the system above 0 °C over the whole test period. The proposed system is judged by the fact that the applicability of the developed system has been verified in consideration of the following three aspects: usability in the operational railway line, effectiveness through icicle prevention performance, and operational safety which does not interfere with train operations.https://www.mdpi.com/2076-3417/12/22/11645icicle preventionguided drainagerailway tunnelconcrete agingwater leakage
spellingShingle Sangjoon Kang
Taehoon Koh
Hanju Yoo
Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold Weather
Applied Sciences
icicle prevention
guided drainage
railway tunnel
concrete aging
water leakage
title Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold Weather
title_full Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold Weather
title_fullStr Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold Weather
title_full_unstemmed Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold Weather
title_short Assessment of the Applicability of a Thawing-Guided Drainage System for Old Railway Tunnel Icicle Prevention in Cold Weather
title_sort assessment of the applicability of a thawing guided drainage system for old railway tunnel icicle prevention in cold weather
topic icicle prevention
guided drainage
railway tunnel
concrete aging
water leakage
url https://www.mdpi.com/2076-3417/12/22/11645
work_keys_str_mv AT sangjoonkang assessmentoftheapplicabilityofathawingguideddrainagesystemforoldrailwaytunneliciclepreventionincoldweather
AT taehoonkoh assessmentoftheapplicabilityofathawingguideddrainagesystemforoldrailwaytunneliciclepreventionincoldweather
AT hanjuyoo assessmentoftheapplicabilityofathawingguideddrainagesystemforoldrailwaytunneliciclepreventionincoldweather