Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconus

Purpose: To evaluate visual and refractive outcomes after intracorneal circular ring implantation with femtosecond laser for keratoconus treatment. Design: Prospective, cohort Methods: Were included 22 eyes of 16 adults patients with central keratoconus who had been implanted with continuous intraco...

Full description

Bibliographic Details
Main Authors: Luis Izquierdo Jr, Ana M Rodríguez, Harumi Moreyra, Josefina Mejías, María A Henríquez
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:The Pan-American Journal of Ophthalmology
Subjects:
Online Access:http://www.thepajo.org/article.asp?issn=2666-4909;year=2017;volume=16;issue=4;spage=110;epage=113;aulast=Jr;type=0
_version_ 1818832851982876672
author Luis Izquierdo Jr
Ana M Rodríguez
Harumi Moreyra
Josefina Mejías
María A Henríquez
author_facet Luis Izquierdo Jr
Ana M Rodríguez
Harumi Moreyra
Josefina Mejías
María A Henríquez
author_sort Luis Izquierdo Jr
collection DOAJ
description Purpose: To evaluate visual and refractive outcomes after intracorneal circular ring implantation with femtosecond laser for keratoconus treatment. Design: Prospective, cohort Methods: Were included 22 eyes of 16 adults patients with central keratoconus who had been implanted with continuous intracorneal circular ring (ICCR) MyoRing (Dioptex GmbH, Linz, Austria) in a pocket created by femtosecond laser (Ziemer Z6 LDV, Port, Switzerland). Visual and refractive outcomes, keratometry, pachymetry and asphericity were evaluated at one, three, six month and one year postoperative. Results: Uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) improved from 1,33 (Standard deviation [SD]: 0,37) to 0,38 logMAR (SD 0,16) (p<.001) and from 0,25 (SD: 0,15) to 0,21 logMAR (SD: 0,23) (p=0,43) respectively at one year postoperative. Central keratometry, sphere, cylinder and corneal asphericity presented reduction of 8,13 Diopters (D) (p<.001), 5,42D (p<.001), 2,03D (p=0.01), 1,46 e2 (p=0,00) respectively. Visual, refractive and keratometric results did not reveal significant changes after the third month of follow up. Conclusion: Intracorneal circular ring implantation using femtosecond laser is an effective and safe procedure for central keratoconus treatment. Keratometric and refractive values can be effectively improved and good visual outcomes achieved. RESUMEN Objetivo: Evaluar los resultados visuales y refractivos tras el implante de anillo intracorneal circular continuo, usando láser de femtosegundo en el tratamiento de pacientes adultos con queratocono. Diseño: Prospectivo de cohorte. Materiales y Métodos: Se incluyeron 22 ojos de 16 pacientes, con diagnóstico de queratocono tipo central a los cuales se les implanto un anillo intracorneal circular continuo (ICCR), MyoRing (Dioptex GmbH, Linz, Austria) en un bolsillo creado con láser de femtosegundo (Ziemer Z6 LDV, Port, Switzerland). Se evaluó resultado visual, refractivo, queratometrías, paquimetría y asfericidad corneal al mes , tres meses, seis meses y a un año posoperatorio. Resultados: La agudeza visual sin corrección (AVSC) y la agudeza visual con corrección (AVCC) mejoraron de 1,33 (Desviación estándar [DE]: 0,37) a 0,38 logMAR ([DE]:0,16, p=0.001) y de 0,25 ([DE]:0,15) a 0,21 logMAR ([DE]:0,23, p= 0,43) respectivamente al año postoperatorio. La queratometría central, la esfera, el cilindro y la asfericidad corneal presentaron disminución de 8,13 Dioptrías (D) (p <.001), 5,42 D (p<.001), 2,03D (p=0.01) y 1,46 e2 (p<0,000) respectivamente. Los resultados visuales, refractivos y queratométricos no presentaron cambios significativos a partir del tercer mes posoperatorio. Conclusiones: El implante del anillo intracorneal circular continuo con láser femtosegundo, demostró ser un procedimiento eficiente y seguro para el tratamiento de queratocono tipo central, mejorando significativamente los valores queratométricos y refractivos, logrando buenos resultados visuales.
first_indexed 2024-12-19T02:09:36Z
format Article
id doaj.art-2d82c6ad66e84b7f82bc5536434cd906
institution Directory Open Access Journal
issn 2666-4909
2666-4909
language English
last_indexed 2024-12-19T02:09:36Z
publishDate 2017-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series The Pan-American Journal of Ophthalmology
spelling doaj.art-2d82c6ad66e84b7f82bc5536434cd9062022-12-21T20:40:50ZengWolters Kluwer Medknow PublicationsThe Pan-American Journal of Ophthalmology2666-49092666-49092017-01-01164110113Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconusLuis Izquierdo JrAna M RodríguezHarumi MoreyraJosefina MejíasMaría A HenríquezPurpose: To evaluate visual and refractive outcomes after intracorneal circular ring implantation with femtosecond laser for keratoconus treatment. Design: Prospective, cohort Methods: Were included 22 eyes of 16 adults patients with central keratoconus who had been implanted with continuous intracorneal circular ring (ICCR) MyoRing (Dioptex GmbH, Linz, Austria) in a pocket created by femtosecond laser (Ziemer Z6 LDV, Port, Switzerland). Visual and refractive outcomes, keratometry, pachymetry and asphericity were evaluated at one, three, six month and one year postoperative. Results: Uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) improved from 1,33 (Standard deviation [SD]: 0,37) to 0,38 logMAR (SD 0,16) (p<.001) and from 0,25 (SD: 0,15) to 0,21 logMAR (SD: 0,23) (p=0,43) respectively at one year postoperative. Central keratometry, sphere, cylinder and corneal asphericity presented reduction of 8,13 Diopters (D) (p<.001), 5,42D (p<.001), 2,03D (p=0.01), 1,46 e2 (p=0,00) respectively. Visual, refractive and keratometric results did not reveal significant changes after the third month of follow up. Conclusion: Intracorneal circular ring implantation using femtosecond laser is an effective and safe procedure for central keratoconus treatment. Keratometric and refractive values can be effectively improved and good visual outcomes achieved. RESUMEN Objetivo: Evaluar los resultados visuales y refractivos tras el implante de anillo intracorneal circular continuo, usando láser de femtosegundo en el tratamiento de pacientes adultos con queratocono. Diseño: Prospectivo de cohorte. Materiales y Métodos: Se incluyeron 22 ojos de 16 pacientes, con diagnóstico de queratocono tipo central a los cuales se les implanto un anillo intracorneal circular continuo (ICCR), MyoRing (Dioptex GmbH, Linz, Austria) en un bolsillo creado con láser de femtosegundo (Ziemer Z6 LDV, Port, Switzerland). Se evaluó resultado visual, refractivo, queratometrías, paquimetría y asfericidad corneal al mes , tres meses, seis meses y a un año posoperatorio. Resultados: La agudeza visual sin corrección (AVSC) y la agudeza visual con corrección (AVCC) mejoraron de 1,33 (Desviación estándar [DE]: 0,37) a 0,38 logMAR ([DE]:0,16, p=0.001) y de 0,25 ([DE]:0,15) a 0,21 logMAR ([DE]:0,23, p= 0,43) respectivamente al año postoperatorio. La queratometría central, la esfera, el cilindro y la asfericidad corneal presentaron disminución de 8,13 Dioptrías (D) (p <.001), 5,42 D (p<.001), 2,03D (p=0.01) y 1,46 e2 (p<0,000) respectivamente. Los resultados visuales, refractivos y queratométricos no presentaron cambios significativos a partir del tercer mes posoperatorio. Conclusiones: El implante del anillo intracorneal circular continuo con láser femtosegundo, demostró ser un procedimiento eficiente y seguro para el tratamiento de queratocono tipo central, mejorando significativamente los valores queratométricos y refractivos, logrando buenos resultados visuales.http://www.thepajo.org/article.asp?issn=2666-4909;year=2017;volume=16;issue=4;spage=110;epage=113;aulast=Jr;type=0keratoconus; intracorneal ring; myoring; femtosecond; keratometry. palabras clave: queratocono; anillo intraestromal; myoring; femtosegundo; queratometría.
spellingShingle Luis Izquierdo Jr
Ana M Rodríguez
Harumi Moreyra
Josefina Mejías
María A Henríquez
Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconus
The Pan-American Journal of Ophthalmology
keratoconus; intracorneal ring; myoring; femtosecond; keratometry. palabras clave: queratocono; anillo intraestromal; myoring; femtosegundo; queratometría.
title Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconus
title_full Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconus
title_fullStr Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconus
title_full_unstemmed Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconus
title_short Implante del Anillo Intracorneal Circular Continuo con Láser Femtosegundo en el Tratamiento de Queratocono: Femtosecond Laser-assisted intracorneal ring implant for keratoconus
title_sort implante del anillo intracorneal circular continuo con laser femtosegundo en el tratamiento de queratocono femtosecond laser assisted intracorneal ring implant for keratoconus
topic keratoconus; intracorneal ring; myoring; femtosecond; keratometry. palabras clave: queratocono; anillo intraestromal; myoring; femtosegundo; queratometría.
url http://www.thepajo.org/article.asp?issn=2666-4909;year=2017;volume=16;issue=4;spage=110;epage=113;aulast=Jr;type=0
work_keys_str_mv AT luisizquierdojr implantedelanillointracornealcircularcontinuoconlaserfemtosegundoeneltratamientodequeratoconofemtosecondlaserassistedintracornealringimplantforkeratoconus
AT anamrodriguez implantedelanillointracornealcircularcontinuoconlaserfemtosegundoeneltratamientodequeratoconofemtosecondlaserassistedintracornealringimplantforkeratoconus
AT harumimoreyra implantedelanillointracornealcircularcontinuoconlaserfemtosegundoeneltratamientodequeratoconofemtosecondlaserassistedintracornealringimplantforkeratoconus
AT josefinamejias implantedelanillointracornealcircularcontinuoconlaserfemtosegundoeneltratamientodequeratoconofemtosecondlaserassistedintracornealringimplantforkeratoconus
AT mariaahenriquez implantedelanillointracornealcircularcontinuoconlaserfemtosegundoeneltratamientodequeratoconofemtosecondlaserassistedintracornealringimplantforkeratoconus