Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain Inspection
By testing the parameters of graphite digestion instrument, the effects of graphite digestion method and microwave digestion method on the determination of total arsenic in rice were analyzed and compared.The results showed that the RSD of rice standard sample digested by graphite digestion method...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Academy of National Food and Strategic Reserves Administration
2021-01-01
|
Series: | Liang you shipin ke-ji |
Subjects: | |
Online Access: | http://lyspkj.ijournal.cn/lyspkj/article/abstract/20210123?st=article_issue |
_version_ | 1827931650234777600 |
---|---|
author | HU Xue-chun REN Ling-yun WANG Li-juan JIN Zeng-wei WU Zhen-zhen ZHAO Ying WANG Rui-jie |
author_facet | HU Xue-chun REN Ling-yun WANG Li-juan JIN Zeng-wei WU Zhen-zhen ZHAO Ying WANG Rui-jie |
author_sort | HU Xue-chun |
collection | DOAJ |
description | By testing the parameters of graphite digestion instrument, the effects of graphite digestion method and microwave digestion method on the determination of total arsenic in rice were analyzed and compared.The results showed that the RSD of rice standard sample digested by graphite digestion method was 5.25%~6.86%, and the relative error between the test result and the standard value was 5.66%~7.55%. The RSD of rice standard sample digested by microwave digestion method was 8.67%~12.26%, and the relative error was 17.96%~21.7%. The accuracy and precision of graphite digestion method are higher than that of microwave digestion method. |
first_indexed | 2024-03-13T06:56:39Z |
format | Article |
id | doaj.art-2de682219d7a4adbbf555cc4bc9ccaaa |
institution | Directory Open Access Journal |
issn | 1007-7561 |
language | English |
last_indexed | 2024-03-13T06:56:39Z |
publishDate | 2021-01-01 |
publisher | Academy of National Food and Strategic Reserves Administration |
record_format | Article |
series | Liang you shipin ke-ji |
spelling | doaj.art-2de682219d7a4adbbf555cc4bc9ccaaa2023-06-07T06:15:24ZengAcademy of National Food and Strategic Reserves AdministrationLiang you shipin ke-ji1007-75612021-01-0129116817210.16210/j.cnki.1007-7561.2021.01.022Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain InspectionHU Xue-chun0REN Ling-yun1WANG Li-juan2JIN Zeng-wei3WU Zhen-zhen4ZHAO Ying5 WANG Rui-jie6Shandong Grain and Oil Testing Center, Jinan, Shandong 250100, ChinaShandong Grain and Oil Testing Center, Jinan, Shandong 250100, ChinaShanxi Grain Quality Monitoring Center, Taiyuan, Shanxi 030024, ChinaShandong Grain and Oil Testing Center, Jinan, Shandong 250100, ChinaShandong Grain and Oil Testing Center, Jinan, Shandong 250100, ChinaShandong Grain and Oil Testing Center, Jinan, Shandong 250100, ChinaShandong Grain and Oil Testing Center, Jinan, Shandong 250100, China By testing the parameters of graphite digestion instrument, the effects of graphite digestion method and microwave digestion method on the determination of total arsenic in rice were analyzed and compared.The results showed that the RSD of rice standard sample digested by graphite digestion method was 5.25%~6.86%, and the relative error between the test result and the standard value was 5.66%~7.55%. The RSD of rice standard sample digested by microwave digestion method was 8.67%~12.26%, and the relative error was 17.96%~21.7%. The accuracy and precision of graphite digestion method are higher than that of microwave digestion method.http://lyspkj.ijournal.cn/lyspkj/article/abstract/20210123?st=article_issuedigestgraphite digestionmicrowave digestiongrainriceinspecttotal arsenic |
spellingShingle | HU Xue-chun REN Ling-yun WANG Li-juan JIN Zeng-wei WU Zhen-zhen ZHAO Ying WANG Rui-jie Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain Inspection Liang you shipin ke-ji digest graphite digestion microwave digestion grain rice inspect total arsenic |
title | Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain Inspection |
title_full | Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain Inspection |
title_fullStr | Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain Inspection |
title_full_unstemmed | Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain Inspection |
title_short | Application of Automatic Graphite Digestion Method in Inspection of Total Arsenic in Grain Inspection |
title_sort | application of automatic graphite digestion method in inspection of total arsenic in grain inspection |
topic | digest graphite digestion microwave digestion grain rice inspect total arsenic |
url | http://lyspkj.ijournal.cn/lyspkj/article/abstract/20210123?st=article_issue |
work_keys_str_mv | AT huxuechun applicationofautomaticgraphitedigestionmethodininspectionoftotalarsenicingraininspection AT renlingyun applicationofautomaticgraphitedigestionmethodininspectionoftotalarsenicingraininspection AT wanglijuan applicationofautomaticgraphitedigestionmethodininspectionoftotalarsenicingraininspection AT jinzengwei applicationofautomaticgraphitedigestionmethodininspectionoftotalarsenicingraininspection AT wuzhenzhen applicationofautomaticgraphitedigestionmethodininspectionoftotalarsenicingraininspection AT zhaoying applicationofautomaticgraphitedigestionmethodininspectionoftotalarsenicingraininspection AT wangruijie applicationofautomaticgraphitedigestionmethodininspectionoftotalarsenicingraininspection |