Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) Phantom

Background: Upgrading analog X-ray systems to digital systems will greatly reduce costs, but there are conflicting opinions on this subject. Therefore, the purpose of this study was to compare image quality and radiation dose in different upgraded analog radiography systems with a digital radiograph...

Full description

Bibliographic Details
Main Authors: Mohammad Reza Choopani, Ali Chapaian
Format: Article
Language:fas
Published: Isfahan University of Medical Sciences 2020-01-01
Series:مجله دانشکده پزشکی اصفهان
Subjects:
Online Access:http://jims.mui.ac.ir/index.php/jims/article/view/12357
_version_ 1797762925325189120
author Mohammad Reza Choopani
Ali Chapaian
author_facet Mohammad Reza Choopani
Ali Chapaian
author_sort Mohammad Reza Choopani
collection DOAJ
description Background: Upgrading analog X-ray systems to digital systems will greatly reduce costs, but there are conflicting opinions on this subject. Therefore, the purpose of this study was to compare image quality and radiation dose in different upgraded analog radiography systems with a digital radiography system. Methods: Image quality and radiation dose of five upgraded analog radiography systems were compared with a digital radiography system using the Contrast Detail Radiography (CDRAD) phantom. Quality of images were independently evaluated on a workstation using a quantitative factor Inverse image quality figure (IQFinv) by three observers. Variations of IQFinv values were compared as a function of the Incident Air Kerma (IAK) parameter for different radiographic systems. Findings: In a fixed IAK (1000 micrograms), the highest IQFinv was for upgraded analog radiography system number 4 (4.97) and the lowest IQFinv was for upgraded analog radiography system number 1 (3.61) (P = 0.001). The quality of images obtained with the upgraded analog radiography systems number 4 and 5 were better than ones of digital radiography. Conclusion: If upgraded analog radiography systems can produce high quality images with low radiation dose compared to digital radiographic systems, the imaging departments is not needed to be spend a lot of money for replacing them with digital radiography systems.
first_indexed 2024-03-12T19:34:15Z
format Article
id doaj.art-2e011fd34a8d4b069d2fa6ac905c0c1a
institution Directory Open Access Journal
issn 1027-7595
1735-854X
language fas
last_indexed 2024-03-12T19:34:15Z
publishDate 2020-01-01
publisher Isfahan University of Medical Sciences
record_format Article
series مجله دانشکده پزشکی اصفهان
spelling doaj.art-2e011fd34a8d4b069d2fa6ac905c0c1a2023-08-02T04:14:38ZfasIsfahan University of Medical Sciencesمجله دانشکده پزشکی اصفهان1027-75951735-854X2020-01-01375471169117510.22122/jims.v37i547.123573512Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) PhantomMohammad Reza Choopani0Ali Chapaian1Student, Department of Technology of Radiology, School of Paramedicine, Isfahan University of Medical Sciences, Isfahan, IranAssociate Professor, Department of Technology of Radiology, School of Paramedicine, Isfahan University of Medical Sciences, Isfahan, IranBackground: Upgrading analog X-ray systems to digital systems will greatly reduce costs, but there are conflicting opinions on this subject. Therefore, the purpose of this study was to compare image quality and radiation dose in different upgraded analog radiography systems with a digital radiography system. Methods: Image quality and radiation dose of five upgraded analog radiography systems were compared with a digital radiography system using the Contrast Detail Radiography (CDRAD) phantom. Quality of images were independently evaluated on a workstation using a quantitative factor Inverse image quality figure (IQFinv) by three observers. Variations of IQFinv values were compared as a function of the Incident Air Kerma (IAK) parameter for different radiographic systems. Findings: In a fixed IAK (1000 micrograms), the highest IQFinv was for upgraded analog radiography system number 4 (4.97) and the lowest IQFinv was for upgraded analog radiography system number 1 (3.61) (P = 0.001). The quality of images obtained with the upgraded analog radiography systems number 4 and 5 were better than ones of digital radiography. Conclusion: If upgraded analog radiography systems can produce high quality images with low radiation dose compared to digital radiographic systems, the imaging departments is not needed to be spend a lot of money for replacing them with digital radiography systems.http://jims.mui.ac.ir/index.php/jims/article/view/12357radiographyimage quality enhancementradiation dosageradiologic phantom
spellingShingle Mohammad Reza Choopani
Ali Chapaian
Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) Phantom
مجله دانشکده پزشکی اصفهان
radiography
image quality enhancement
radiation dosage
radiologic phantom
title Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) Phantom
title_full Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) Phantom
title_fullStr Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) Phantom
title_full_unstemmed Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) Phantom
title_short Evaluation of Image Quality and Radiation Dose in Upgraded Analog Radiographic Systems Using the Contrast Detail Radiography (CDRAD) Phantom
title_sort evaluation of image quality and radiation dose in upgraded analog radiographic systems using the contrast detail radiography cdrad phantom
topic radiography
image quality enhancement
radiation dosage
radiologic phantom
url http://jims.mui.ac.ir/index.php/jims/article/view/12357
work_keys_str_mv AT mohammadrezachoopani evaluationofimagequalityandradiationdoseinupgradedanalogradiographicsystemsusingthecontrastdetailradiographycdradphantom
AT alichapaian evaluationofimagequalityandradiationdoseinupgradedanalogradiographicsystemsusingthecontrastdetailradiographycdradphantom