Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults

This study aims to evaluate the clinical results of posterior chamber implantable collamer lens (ICL) implantation in adults with high myopic anisometropic amblyopia. Thirteen patients aged 27.04±7.24y (range 19.2 to 42.5) were studied. ICL implantation was performed in 13 amblyopic eyes. The mean m...

Full description

Bibliographic Details
Main Authors: Jing Zhang, Jing Zhuang, Ke-Ming Yu
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2018-11-01
Series:International Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.cn/en_publish/2018/11/20181121.pdf
_version_ 1828191787762581504
author Jing Zhang
Jing Zhuang
Ke-Ming Yu
author_facet Jing Zhang
Jing Zhuang
Ke-Ming Yu
author_sort Jing Zhang
collection DOAJ
description This study aims to evaluate the clinical results of posterior chamber implantable collamer lens (ICL) implantation in adults with high myopic anisometropic amblyopia. Thirteen patients aged 27.04±7.24y (range 19.2 to 42.5) were studied. ICL implantation was performed in 13 amblyopic eyes. The mean myopic anisometropia was significantly dropped from -10.70±3.02 D preoperatively to +0.09±1.67 D at 1mo postoperatively. The logMAR CDVA at 3d, 1, 3 and mean 9mo postoperatively improved by a mean of 1.69, 2.50, 3.01 and 3.00 lines and gained more than 2 lines accounted for 23.08% (3 eyes), 41.67% (5 eyes), 63.63% (7 eyes) and 55.56% (5 eyes), respectively. The contrast sensitivity of amblyopic eyes was significantly increased after surgery. Four patients partially recovered near stereopsis (400” to 100”). There was no severe complications were observed. ICL implantation alone can improve vision, contrast sensitivity, and partial restoration of binocular vision in adult patients with high myopic anisometropia.
first_indexed 2024-04-12T08:44:49Z
format Article
id doaj.art-2e48bcd41a5e4264bba0b705e30bd0f8
institution Directory Open Access Journal
issn 2222-3959
2227-4898
language English
last_indexed 2024-04-12T08:44:49Z
publishDate 2018-11-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series International Journal of Ophthalmology
spelling doaj.art-2e48bcd41a5e4264bba0b705e30bd0f82022-12-22T03:39:45ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982018-11-0111111870187410.18240/ijo.2018.11.21Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adultsJing Zhang0Jing Zhuang1Ke-Ming Yu2Shenzhen Eye Hospital, Shenzhen Key Laboratory of Ophthalmology, Affiliated Shenzhen Eye Hospital of Jinan University, Shenzhen 518040, Guangdong Province, China.State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, ChinaState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, ChinaThis study aims to evaluate the clinical results of posterior chamber implantable collamer lens (ICL) implantation in adults with high myopic anisometropic amblyopia. Thirteen patients aged 27.04±7.24y (range 19.2 to 42.5) were studied. ICL implantation was performed in 13 amblyopic eyes. The mean myopic anisometropia was significantly dropped from -10.70±3.02 D preoperatively to +0.09±1.67 D at 1mo postoperatively. The logMAR CDVA at 3d, 1, 3 and mean 9mo postoperatively improved by a mean of 1.69, 2.50, 3.01 and 3.00 lines and gained more than 2 lines accounted for 23.08% (3 eyes), 41.67% (5 eyes), 63.63% (7 eyes) and 55.56% (5 eyes), respectively. The contrast sensitivity of amblyopic eyes was significantly increased after surgery. Four patients partially recovered near stereopsis (400” to 100”). There was no severe complications were observed. ICL implantation alone can improve vision, contrast sensitivity, and partial restoration of binocular vision in adult patients with high myopic anisometropia.http://www.ijo.cn/en_publish/2018/11/20181121.pdfphakic intraocular lensmyopic anisometropicamblyopiarefractive surgery
spellingShingle Jing Zhang
Jing Zhuang
Ke-Ming Yu
Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
International Journal of Ophthalmology
phakic intraocular lens
myopic anisometropic
amblyopia
refractive surgery
title Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
title_full Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
title_fullStr Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
title_full_unstemmed Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
title_short Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
title_sort posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults
topic phakic intraocular lens
myopic anisometropic
amblyopia
refractive surgery
url http://www.ijo.cn/en_publish/2018/11/20181121.pdf
work_keys_str_mv AT jingzhang posteriorchamberphakicintraocularlensforthecorrectionofhighmyopicanisometropicamblyopiainadults
AT jingzhuang posteriorchamberphakicintraocularlensforthecorrectionofhighmyopicanisometropicamblyopiainadults
AT kemingyu posteriorchamberphakicintraocularlensforthecorrectionofhighmyopicanisometropicamblyopiainadults