A line selection method for single phase ground fault in coal mine power supply system based on wavelet packet

In view of problems of low accuracy and poor reliability of line selection methods for single phase ground fault in existing coal mine power supply system, a line selection method for single phase ground fault in coal mine power supply system based on wavelet packet was proposed. At first, transient...

Full description

Bibliographic Details
Main Authors: LUO Chao, GENG Pulong, QU Bingni, SONG Jiancheng, LIU Jucai, DU Zhili, YUAN Leiming
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2018-02-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2017050003
_version_ 1797868901824987136
author LUO Chao
GENG Pulong
QU Bingni
SONG Jiancheng
LIU Jucai
DU Zhili
YUAN Leiming
author_facet LUO Chao
GENG Pulong
QU Bingni
SONG Jiancheng
LIU Jucai
DU Zhili
YUAN Leiming
author_sort LUO Chao
collection DOAJ
description In view of problems of low accuracy and poor reliability of line selection methods for single phase ground fault in existing coal mine power supply system, a line selection method for single phase ground fault in coal mine power supply system based on wavelet packet was proposed. At first, transient zero modal current of each line is decomposed by wavelet packet, the lowest frequency band containing steady power frequency is eliminated, and sum of wavelet packet energy of each frequency band is calculated and sorted. And then, characteristic frequency band of each line is selected based on principle of the maximum energy, the line with opposite polarity is identified as fault line by comparing polarities of the modulus maximum of the wavelet packets decomposition coefficients of characteristic frequency band of lines. The double criteria for fault line selection of single phase ground fault can be formed by the different characteristics of transient zero modal currents between fault line and non-fault line, which overcomes the problem that single criteria may not select fault line correctly. The simulation experiments results prove correctness and effectiveness of the method.
first_indexed 2024-04-10T00:04:12Z
format Article
id doaj.art-2e6481d06c824a8bb8b582d36ef8de20
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-10T00:04:12Z
publishDate 2018-02-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-2e6481d06c824a8bb8b582d36ef8de202023-03-17T01:20:08ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2018-02-01442687410.13272/j.issn.1671-251x.2017050003A line selection method for single phase ground fault in coal mine power supply system based on wavelet packetLUO ChaoGENG PulongQU BingniSONG Jiancheng0LIU JucaiDU ZhiliYUAN LeimingTechnology, Taiyuan University of Technology, Taiyuan 030024, China;2. Shanxi Key Laboratory of Mining Electrical Equipment and Intelligent Control, Taiyuan University of Technology, Taiyuan 030024, China; 3.Jincheng Anthracite Mining Group, Jincheng 048006, China;4.Shanxi Lingzhida Coal Co., Ltd., Changzhi 046606, ChinaIn view of problems of low accuracy and poor reliability of line selection methods for single phase ground fault in existing coal mine power supply system, a line selection method for single phase ground fault in coal mine power supply system based on wavelet packet was proposed. At first, transient zero modal current of each line is decomposed by wavelet packet, the lowest frequency band containing steady power frequency is eliminated, and sum of wavelet packet energy of each frequency band is calculated and sorted. And then, characteristic frequency band of each line is selected based on principle of the maximum energy, the line with opposite polarity is identified as fault line by comparing polarities of the modulus maximum of the wavelet packets decomposition coefficients of characteristic frequency band of lines. The double criteria for fault line selection of single phase ground fault can be formed by the different characteristics of transient zero modal currents between fault line and non-fault line, which overcomes the problem that single criteria may not select fault line correctly. The simulation experiments results prove correctness and effectiveness of the method.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2017050003mine power supplysingle phase ground faultfault line selectiontransient zero model currentwavelet packet energycharacteristic frequency band
spellingShingle LUO Chao
GENG Pulong
QU Bingni
SONG Jiancheng
LIU Jucai
DU Zhili
YUAN Leiming
A line selection method for single phase ground fault in coal mine power supply system based on wavelet packet
Gong-kuang zidonghua
mine power supply
single phase ground fault
fault line selection
transient zero model current
wavelet packet energy
characteristic frequency band
title A line selection method for single phase ground fault in coal mine power supply system based on wavelet packet
title_full A line selection method for single phase ground fault in coal mine power supply system based on wavelet packet
title_fullStr A line selection method for single phase ground fault in coal mine power supply system based on wavelet packet
title_full_unstemmed A line selection method for single phase ground fault in coal mine power supply system based on wavelet packet
title_short A line selection method for single phase ground fault in coal mine power supply system based on wavelet packet
title_sort line selection method for single phase ground fault in coal mine power supply system based on wavelet packet
topic mine power supply
single phase ground fault
fault line selection
transient zero model current
wavelet packet energy
characteristic frequency band
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2017050003
work_keys_str_mv AT luochao alineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT gengpulong alineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT qubingni alineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT songjiancheng alineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT liujucai alineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT duzhili alineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT yuanleiming alineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT luochao lineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT gengpulong lineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT qubingni lineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT songjiancheng lineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT liujucai lineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT duzhili lineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket
AT yuanleiming lineselectionmethodforsinglephasegroundfaultincoalminepowersupplysystembasedonwaveletpacket