Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits
Taiwan’s power system is isolated and not supported by other interconnected systems. Consequently, the system frequency immediately reflects changes in the system loads. Pumped storage units are crucial for controlling power frequency. These units provide main or auxiliary capacities, reducing the a...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2013-07-01
|
Series: | Energies |
Subjects: | |
Online Access: | http://www.mdpi.com/1996-1073/6/7/3224 |
_version_ | 1798006577598300160 |
---|---|
author | Ming-Tse Kuo Shiue-Der Lu |
author_facet | Ming-Tse Kuo Shiue-Der Lu |
author_sort | Ming-Tse Kuo |
collection | DOAJ |
description | Taiwan’s power system is isolated and not supported by other interconnected systems. Consequently, the system frequency immediately reflects changes in the system loads. Pumped storage units are crucial for controlling power frequency. These units provide main or auxiliary capacities, reducing the allocation of frequency-regulating reserve (FRR) and further reducing generation costs in system operations. Taiwan’s Longmen Nuclear Power Plant is set to be converted for commercial operations, which will significantly alter the spinning reserves in the power system. Thus, this study proposes a safe and economic pumped storage unit dispatch strategy. This strategy is used to determine the optimal FRR capacity and 1-min recovery frequency in a generator failure occurrence at the Longmen Power Plant. In addition, this study considered transmission capacity constraints and conducted power flow analysis of the power systems in Northern, Central, and Southern Taiwan. The results indicated that, in the event of a failure at Longmen Power Plant, the proposed strategy can not only recover the system frequency to an acceptable range to prevent underfrequency load-shedding, but can also mitigate transmission line overloading. |
first_indexed | 2024-04-11T12:56:55Z |
format | Article |
id | doaj.art-2f16c700ddd5431088a1b956a9ea1c47 |
institution | Directory Open Access Journal |
issn | 1996-1073 |
language | English |
last_indexed | 2024-04-11T12:56:55Z |
publishDate | 2013-07-01 |
publisher | MDPI AG |
record_format | Article |
series | Energies |
spelling | doaj.art-2f16c700ddd5431088a1b956a9ea1c472022-12-22T04:23:03ZengMDPI AGEnergies1996-10732013-07-01673224324410.3390/en6073224Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line LimitsMing-Tse KuoShiue-Der LuTaiwan’s power system is isolated and not supported by other interconnected systems. Consequently, the system frequency immediately reflects changes in the system loads. Pumped storage units are crucial for controlling power frequency. These units provide main or auxiliary capacities, reducing the allocation of frequency-regulating reserve (FRR) and further reducing generation costs in system operations. Taiwan’s Longmen Nuclear Power Plant is set to be converted for commercial operations, which will significantly alter the spinning reserves in the power system. Thus, this study proposes a safe and economic pumped storage unit dispatch strategy. This strategy is used to determine the optimal FRR capacity and 1-min recovery frequency in a generator failure occurrence at the Longmen Power Plant. In addition, this study considered transmission capacity constraints and conducted power flow analysis of the power systems in Northern, Central, and Southern Taiwan. The results indicated that, in the event of a failure at Longmen Power Plant, the proposed strategy can not only recover the system frequency to an acceptable range to prevent underfrequency load-shedding, but can also mitigate transmission line overloading.http://www.mdpi.com/1996-1073/6/7/3224Taiwan’s power systempumped storage unitsfrequency-regulating reserveLongmen Nuclear Power Plant1-min recovery frequencyunderfrequency load-shedding |
spellingShingle | Ming-Tse Kuo Shiue-Der Lu Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits Energies Taiwan’s power system pumped storage units frequency-regulating reserve Longmen Nuclear Power Plant 1-min recovery frequency underfrequency load-shedding |
title | Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits |
title_full | Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits |
title_fullStr | Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits |
title_full_unstemmed | Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits |
title_short | Experimental Research and Control Strategy of Pumped Storage Units Dispatching in the Taiwan Power System Considering Transmission Line Limits |
title_sort | experimental research and control strategy of pumped storage units dispatching in the taiwan power system considering transmission line limits |
topic | Taiwan’s power system pumped storage units frequency-regulating reserve Longmen Nuclear Power Plant 1-min recovery frequency underfrequency load-shedding |
url | http://www.mdpi.com/1996-1073/6/7/3224 |
work_keys_str_mv | AT mingtsekuo experimentalresearchandcontrolstrategyofpumpedstorageunitsdispatchinginthetaiwanpowersystemconsideringtransmissionlinelimits AT shiuederlu experimentalresearchandcontrolstrategyofpumpedstorageunitsdispatchinginthetaiwanpowersystemconsideringtransmissionlinelimits |