Fully automated extraction of coronary main branches based on directional minimal path
It has been a challenging but significant research topic to extract the centerlines of the coronary arteries of the CTA volume in clinical applications. A new method is proposed to full-automatically extract and recognize the centerlines of the major branches in this paper. This method, which is cal...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
National Computer System Engineering Research Institute of China
2018-10-01
|
Series: | Dianzi Jishu Yingyong |
Subjects: | |
Online Access: | http://www.chinaaet.com/article/3000092837 |
_version_ | 1818339435779981312 |
---|---|
author | Liu Liu Xu Jin Wu Pengfei |
author_facet | Liu Liu Xu Jin Wu Pengfei |
author_sort | Liu Liu |
collection | DOAJ |
description | It has been a challenging but significant research topic to extract the centerlines of the coronary arteries of the CTA volume in clinical applications. A new method is proposed to full-automatically extract and recognize the centerlines of the major branches in this paper. This method, which is called the directional minimal path, originates from an improved minimal path algorithm. In this method, the cost function is redefined, and the starting point of the coronary is automatically detected. The proposed method is validated by extracting and recognizing the three major coronary branches, and the average overlap percentage was 81.0%. |
first_indexed | 2024-12-13T15:26:58Z |
format | Article |
id | doaj.art-2f7b60a7788f4f95acee5dca30b62bbf |
institution | Directory Open Access Journal |
issn | 0258-7998 |
language | zho |
last_indexed | 2024-12-13T15:26:58Z |
publishDate | 2018-10-01 |
publisher | National Computer System Engineering Research Institute of China |
record_format | Article |
series | Dianzi Jishu Yingyong |
spelling | doaj.art-2f7b60a7788f4f95acee5dca30b62bbf2022-12-21T23:40:19ZzhoNational Computer System Engineering Research Institute of ChinaDianzi Jishu Yingyong0258-79982018-10-01441013613910.16157/j.issn.0258-7998.1812333000092837Fully automated extraction of coronary main branches based on directional minimal pathLiu Liu0Xu Jin1Wu Pengfei2Engineering Research Center of Wireless Communication,Nanjing University of Posts and Telecommunication,Nanjing 210003,ChinaEngineering Research Center of Wireless Communication,Nanjing University of Posts and Telecommunication,Nanjing 210003,ChinaEngineering Research Center of Wireless Communication,Nanjing University of Posts and Telecommunication,Nanjing 210003,ChinaIt has been a challenging but significant research topic to extract the centerlines of the coronary arteries of the CTA volume in clinical applications. A new method is proposed to full-automatically extract and recognize the centerlines of the major branches in this paper. This method, which is called the directional minimal path, originates from an improved minimal path algorithm. In this method, the cost function is redefined, and the starting point of the coronary is automatically detected. The proposed method is validated by extracting and recognizing the three major coronary branches, and the average overlap percentage was 81.0%.http://www.chinaaet.com/article/3000092837cta imagecoronary centerlineprior modelminimal pathcoronary extraction |
spellingShingle | Liu Liu Xu Jin Wu Pengfei Fully automated extraction of coronary main branches based on directional minimal path Dianzi Jishu Yingyong cta image coronary centerline prior model minimal path coronary extraction |
title | Fully automated extraction of coronary main branches based on directional minimal path |
title_full | Fully automated extraction of coronary main branches based on directional minimal path |
title_fullStr | Fully automated extraction of coronary main branches based on directional minimal path |
title_full_unstemmed | Fully automated extraction of coronary main branches based on directional minimal path |
title_short | Fully automated extraction of coronary main branches based on directional minimal path |
title_sort | fully automated extraction of coronary main branches based on directional minimal path |
topic | cta image coronary centerline prior model minimal path coronary extraction |
url | http://www.chinaaet.com/article/3000092837 |
work_keys_str_mv | AT liuliu fullyautomatedextractionofcoronarymainbranchesbasedondirectionalminimalpath AT xujin fullyautomatedextractionofcoronarymainbranchesbasedondirectionalminimalpath AT wupengfei fullyautomatedextractionofcoronarymainbranchesbasedondirectionalminimalpath |