Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, China

The thermal storage temperature and water-rock interaction process of the Lushan convective geothermal system (Qinling stratigraphic zonation fracture zone in China) are clarified by using surface cold water and geothermal fluid as the research objects. In this study, a conceptual model of the tempe...

Full description

Bibliographic Details
Main Authors: Wang Qi, Zhou Dongxu, Liao Jiajia, Liu Yuntao, Wang Xinyi
Format: Article
Language:English
Published: Hindawi-Wiley 2023-01-01
Series:Geofluids
Online Access:http://dx.doi.org/10.1155/2023/7149973
_version_ 1797794684117975040
author Wang Qi
Zhou Dongxu
Liao Jiajia
Liu Yuntao
Wang Xinyi
author_facet Wang Qi
Zhou Dongxu
Liao Jiajia
Liu Yuntao
Wang Xinyi
author_sort Wang Qi
collection DOAJ
description The thermal storage temperature and water-rock interaction process of the Lushan convective geothermal system (Qinling stratigraphic zonation fracture zone in China) are clarified by using surface cold water and geothermal fluid as the research objects. In this study, a conceptual model of the temperature profile of the geothermal system in the study area was developed using surface temperature inversion, the cation temperature scale, the SiO2 temperature scale method, the mineral equilibrium phase method, the silicon-enthalpy model, the FixAl method, and the Cl-enthalpy model. The inversion temperature at the surface is in the range of 33-39°C, and the temperature difference indicates the direction of the Checun-Lushan fracture. The study area is recharged from atmospheric precipitation, and the temperature of the recharge area is approximately 5.8–7.7°C (the temperature of the alkali field is approximately 10°C), and the recharge elevation is approximately 1200 m. The thermal storage pattern in the study area is near-surface hydrothermal thermal storage transferred to shallow thermal storage and then to deep thermal storage. The near-surface hydrothermal thermal storage temperature is at a constant temperature of 60°C, and the shallow thermal storage temperature is calculated by K-Mg and Li-Mg geothermometers to be between 99 and 112°C. The thermal storage temperature is simulated using the FixAl method, with deviation values ranging from 2.9% to 15.0%. The silicon-enthalpy model calculates the deep thermal storage temperature to be between 181 and 230°C. The mixing ratio of geothermal water in the study area is extremely high, with a cold water mixing ratio of 85.4–94.8%. The home ground fluid temperature was estimated to be approximately 282°C using the Cl-enthalpy model. The main thermally controlled conductivity channel in the study area is the Checun-Lushan fracture zone. The water vapor formed by convection at depth moves upward to approximately 5 km to form a deep thermal reservoir, and this convection and upward movement cause it to mix with cold water from the fracture zone to form a shallow thermal reservoir, which moves to the near-surface, forming a hydrothermal-type reservoir, which is later discharged in the form of a spring. The conceptual model of geothermal system temperature established in this study provides a basis for further development and utilization of Lushan hot springs and provides guidance for future thermal storage temperature calculations of convection-type geothermal systems in uplifted mountains.
first_indexed 2024-03-13T03:06:30Z
format Article
id doaj.art-2faf5e20b8fa4a8abd6bdd555297f72d
institution Directory Open Access Journal
issn 1468-8123
language English
last_indexed 2024-03-13T03:06:30Z
publishDate 2023-01-01
publisher Hindawi-Wiley
record_format Article
series Geofluids
spelling doaj.art-2faf5e20b8fa4a8abd6bdd555297f72d2023-06-27T00:00:03ZengHindawi-WileyGeofluids1468-81232023-01-01202310.1155/2023/7149973Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, ChinaWang Qi0Zhou Dongxu1Liao Jiajia2Liu Yuntao3Wang Xinyi4College of Geosciences and EngineeringCollege of Geosciences and EngineeringInstitute of Resources & EnvironmentFifth Geological Exploration Institute of Henan Bureau of Geology and Mineral Exploration and DevelopmentInstitute of Resources & EnvironmentThe thermal storage temperature and water-rock interaction process of the Lushan convective geothermal system (Qinling stratigraphic zonation fracture zone in China) are clarified by using surface cold water and geothermal fluid as the research objects. In this study, a conceptual model of the temperature profile of the geothermal system in the study area was developed using surface temperature inversion, the cation temperature scale, the SiO2 temperature scale method, the mineral equilibrium phase method, the silicon-enthalpy model, the FixAl method, and the Cl-enthalpy model. The inversion temperature at the surface is in the range of 33-39°C, and the temperature difference indicates the direction of the Checun-Lushan fracture. The study area is recharged from atmospheric precipitation, and the temperature of the recharge area is approximately 5.8–7.7°C (the temperature of the alkali field is approximately 10°C), and the recharge elevation is approximately 1200 m. The thermal storage pattern in the study area is near-surface hydrothermal thermal storage transferred to shallow thermal storage and then to deep thermal storage. The near-surface hydrothermal thermal storage temperature is at a constant temperature of 60°C, and the shallow thermal storage temperature is calculated by K-Mg and Li-Mg geothermometers to be between 99 and 112°C. The thermal storage temperature is simulated using the FixAl method, with deviation values ranging from 2.9% to 15.0%. The silicon-enthalpy model calculates the deep thermal storage temperature to be between 181 and 230°C. The mixing ratio of geothermal water in the study area is extremely high, with a cold water mixing ratio of 85.4–94.8%. The home ground fluid temperature was estimated to be approximately 282°C using the Cl-enthalpy model. The main thermally controlled conductivity channel in the study area is the Checun-Lushan fracture zone. The water vapor formed by convection at depth moves upward to approximately 5 km to form a deep thermal reservoir, and this convection and upward movement cause it to mix with cold water from the fracture zone to form a shallow thermal reservoir, which moves to the near-surface, forming a hydrothermal-type reservoir, which is later discharged in the form of a spring. The conceptual model of geothermal system temperature established in this study provides a basis for further development and utilization of Lushan hot springs and provides guidance for future thermal storage temperature calculations of convection-type geothermal systems in uplifted mountains.http://dx.doi.org/10.1155/2023/7149973
spellingShingle Wang Qi
Zhou Dongxu
Liao Jiajia
Liu Yuntao
Wang Xinyi
Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, China
Geofluids
title Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, China
title_full Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, China
title_fullStr Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, China
title_full_unstemmed Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, China
title_short Reservoir Temperature Calculation and Modeling for Convective Geothermal Systems: Case Study of Five Major Hot Springs in Lushan, Henan, China
title_sort reservoir temperature calculation and modeling for convective geothermal systems case study of five major hot springs in lushan henan china
url http://dx.doi.org/10.1155/2023/7149973
work_keys_str_mv AT wangqi reservoirtemperaturecalculationandmodelingforconvectivegeothermalsystemscasestudyoffivemajorhotspringsinlushanhenanchina
AT zhoudongxu reservoirtemperaturecalculationandmodelingforconvectivegeothermalsystemscasestudyoffivemajorhotspringsinlushanhenanchina
AT liaojiajia reservoirtemperaturecalculationandmodelingforconvectivegeothermalsystemscasestudyoffivemajorhotspringsinlushanhenanchina
AT liuyuntao reservoirtemperaturecalculationandmodelingforconvectivegeothermalsystemscasestudyoffivemajorhotspringsinlushanhenanchina
AT wangxinyi reservoirtemperaturecalculationandmodelingforconvectivegeothermalsystemscasestudyoffivemajorhotspringsinlushanhenanchina