Multi-detector computer tomography as effective method for Crohn's disease diagnostics

Aim of investigation. Improvement of diagnostics and efficacy of radiological methods of investigation by technique computer-tomography (CT) enterography at inflammatory bowel diseases.Material and methods. Original investigation was based on the data of comprehensive clinical and instrumental inves...

Full description

Bibliographic Details
Main Authors: A. A. Tikhonov, A. V. Gorinov, I. V. Zarodnyuk, I. L. Khalif, Ye. S. Korolevsky
Format: Article
Language:Russian
Published: Gastro LLC 2024-03-01
Series:Российский журнал гастроэнтерологии, гепатологии, колопроктологии
Subjects:
Online Access:https://www.gastro-j.ru/jour/article/view/1004
_version_ 1797245106433032192
author A. A. Tikhonov
A. V. Gorinov
I. V. Zarodnyuk
I. L. Khalif
Ye. S. Korolevsky
author_facet A. A. Tikhonov
A. V. Gorinov
I. V. Zarodnyuk
I. L. Khalif
Ye. S. Korolevsky
author_sort A. A. Tikhonov
collection DOAJ
description Aim of investigation. Improvement of diagnostics and efficacy of radiological methods of investigation by technique computer-tomography (CT) enterography at inflammatory bowel diseases.Material and methods. Original investigation was based on the data of comprehensive clinical and instrumental investigation of 111 patients with suspected Crohn's disease (CD). The set of tests included colonoscopy, abdominal US, CT-enterography, X-ray investigation of small intestine. Signs of CD were obtained by CT-enterography in 62 patients (55,9%), in all of these cases it was possible to establish localization of process, to estimate its spread and reveal complications.Results. Data of roentgenological and CT investigation comparative analysis were similar. Thus, CT-enterography technique of can be regarded either as alternative to X-ray investigation of the small intestine at CD diagnostics or important addition to diagnostic algorithm for this group of patients.
first_indexed 2024-04-24T19:21:38Z
format Article
id doaj.art-2fd9c677ed4b414da0d6811aaf9b011a
institution Directory Open Access Journal
issn 1382-4376
2658-6673
language Russian
last_indexed 2024-04-24T19:21:38Z
publishDate 2024-03-01
publisher Gastro LLC
record_format Article
series Российский журнал гастроэнтерологии, гепатологии, колопроктологии
spelling doaj.art-2fd9c677ed4b414da0d6811aaf9b011a2024-03-25T16:53:11ZrusGastro LLCРоссийский журнал гастроэнтерологии, гепатологии, колопроктологии1382-43762658-66732024-03-012527983612Multi-detector computer tomography as effective method for Crohn's disease diagnosticsA. A. Tikhonov0A. V. Gorinov1I. V. Zarodnyuk2I. L. Khalif3Ye. S. Korolevsky4Federal government-financed institution «State Scientific Center of Coloproctology» Ministry of healthcare of the Russian FederationFederal government-financed institution «State Scientific Center of Coloproctology» Ministry of healthcare of the Russian FederationFederal government-financed institution «State Scientific Center of Coloproctology» Ministry of healthcare of the Russian FederationFederal government-financed institution «State Scientific Center of Coloproctology» Ministry of healthcare of the Russian FederationFederal government-financed institution «State Scientific Center of Coloproctology» Ministry of healthcare of the Russian FederationAim of investigation. Improvement of diagnostics and efficacy of radiological methods of investigation by technique computer-tomography (CT) enterography at inflammatory bowel diseases.Material and methods. Original investigation was based on the data of comprehensive clinical and instrumental investigation of 111 patients with suspected Crohn's disease (CD). The set of tests included colonoscopy, abdominal US, CT-enterography, X-ray investigation of small intestine. Signs of CD were obtained by CT-enterography in 62 patients (55,9%), in all of these cases it was possible to establish localization of process, to estimate its spread and reveal complications.Results. Data of roentgenological and CT investigation comparative analysis were similar. Thus, CT-enterography technique of can be regarded either as alternative to X-ray investigation of the small intestine at CD diagnostics or important addition to diagnostic algorithm for this group of patients.https://www.gastro-j.ru/jour/article/view/1004crohn's diseasethe small intestinemulti-detector computer tomography
spellingShingle A. A. Tikhonov
A. V. Gorinov
I. V. Zarodnyuk
I. L. Khalif
Ye. S. Korolevsky
Multi-detector computer tomography as effective method for Crohn's disease diagnostics
Российский журнал гастроэнтерологии, гепатологии, колопроктологии
crohn's disease
the small intestine
multi-detector computer tomography
title Multi-detector computer tomography as effective method for Crohn's disease diagnostics
title_full Multi-detector computer tomography as effective method for Crohn's disease diagnostics
title_fullStr Multi-detector computer tomography as effective method for Crohn's disease diagnostics
title_full_unstemmed Multi-detector computer tomography as effective method for Crohn's disease diagnostics
title_short Multi-detector computer tomography as effective method for Crohn's disease diagnostics
title_sort multi detector computer tomography as effective method for crohn s disease diagnostics
topic crohn's disease
the small intestine
multi-detector computer tomography
url https://www.gastro-j.ru/jour/article/view/1004
work_keys_str_mv AT aatikhonov multidetectorcomputertomographyaseffectivemethodforcrohnsdiseasediagnostics
AT avgorinov multidetectorcomputertomographyaseffectivemethodforcrohnsdiseasediagnostics
AT ivzarodnyuk multidetectorcomputertomographyaseffectivemethodforcrohnsdiseasediagnostics
AT ilkhalif multidetectorcomputertomographyaseffectivemethodforcrohnsdiseasediagnostics
AT yeskorolevsky multidetectorcomputertomographyaseffectivemethodforcrohnsdiseasediagnostics