Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve

Abstract Background Fractional flow reverse (FFR) is the gold standard assessment of the hemodynamic significance of coronary stenoses. However, it requires the catheterization of the coronary artery to determine the pressure waveforms proximal and distal to the stenosis. On the contrary, computatio...

Full description

Bibliographic Details
Main Authors: R. Agujetas, M. R. González-Fernández, J. M. Nogales-Asensio, J. M. Montanero
Format: Article
Language:English
Published: BMC 2018-05-01
Series:BioMedical Engineering OnLine
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12938-018-0503-7
_version_ 1828401479249035264
author R. Agujetas
M. R. González-Fernández
J. M. Nogales-Asensio
J. M. Montanero
author_facet R. Agujetas
M. R. González-Fernández
J. M. Nogales-Asensio
J. M. Montanero
author_sort R. Agujetas
collection DOAJ
description Abstract Background Fractional flow reverse (FFR) is the gold standard assessment of the hemodynamic significance of coronary stenoses. However, it requires the catheterization of the coronary artery to determine the pressure waveforms proximal and distal to the stenosis. On the contrary, computational fluid dynamics enables the calculation of the FFR value from relatively non-invasive computed tomography angiography (CTA). Methods We analyze the flow across idealized highly-eccentric coronary stenoses by solving the Navier–Stokes equations. We examine the influence of several aspects (approximations) of the simulation method on the calculation of the FFR value. We study the effects on the FFR value of errors made in the segmentation of clinical images. For this purpose, we compare the FFR value for the nominal geometry with that calculated for other shapes that slightly deviate from that geometry. This analysis is conducted for a range of stenosis severities and different inlet velocity and pressure waveforms. Results and conclusions The errors made in assuming a uniform velocity profile in front of the stenosis, as well as those due to the Newtonian and laminar approximations, are negligible for stenosis severities leading to FFR values around the threshold 0.8. The limited resolution of the stenosis geometry reconstruction is the major source of error when predicting the FFR value. Both systematic errors in the contour detection of just 1-pixel size in the CTA images and a low-quality representation of the stenosis surface (coarse faceted geometry) may yield wrong outcomes of the FFR assessment for an important set of eccentric stenoses. On the contrary, the spatial resolution of images acquired with optical coherence tomography may be sufficient to ensure accurate predictions for the FFR value.
first_indexed 2024-12-10T09:47:40Z
format Article
id doaj.art-3045fa61238e411887328a9201c36fb4
institution Directory Open Access Journal
issn 1475-925X
language English
last_indexed 2024-12-10T09:47:40Z
publishDate 2018-05-01
publisher BMC
record_format Article
series BioMedical Engineering OnLine
spelling doaj.art-3045fa61238e411887328a9201c36fb42022-12-22T01:53:45ZengBMCBioMedical Engineering OnLine1475-925X2018-05-0117112210.1186/s12938-018-0503-7Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserveR. Agujetas0M. R. González-Fernández1J. M. Nogales-Asensio2J. M. Montanero3Depto. de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de ExtremaduraServicio de Cardiología, Hospital Infanta CristinaServicio de Cardiología, Hospital Infanta CristinaDepto. de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de ExtremaduraAbstract Background Fractional flow reverse (FFR) is the gold standard assessment of the hemodynamic significance of coronary stenoses. However, it requires the catheterization of the coronary artery to determine the pressure waveforms proximal and distal to the stenosis. On the contrary, computational fluid dynamics enables the calculation of the FFR value from relatively non-invasive computed tomography angiography (CTA). Methods We analyze the flow across idealized highly-eccentric coronary stenoses by solving the Navier–Stokes equations. We examine the influence of several aspects (approximations) of the simulation method on the calculation of the FFR value. We study the effects on the FFR value of errors made in the segmentation of clinical images. For this purpose, we compare the FFR value for the nominal geometry with that calculated for other shapes that slightly deviate from that geometry. This analysis is conducted for a range of stenosis severities and different inlet velocity and pressure waveforms. Results and conclusions The errors made in assuming a uniform velocity profile in front of the stenosis, as well as those due to the Newtonian and laminar approximations, are negligible for stenosis severities leading to FFR values around the threshold 0.8. The limited resolution of the stenosis geometry reconstruction is the major source of error when predicting the FFR value. Both systematic errors in the contour detection of just 1-pixel size in the CTA images and a low-quality representation of the stenosis surface (coarse faceted geometry) may yield wrong outcomes of the FFR assessment for an important set of eccentric stenoses. On the contrary, the spatial resolution of images acquired with optical coherence tomography may be sufficient to ensure accurate predictions for the FFR value.http://link.springer.com/article/10.1186/s12938-018-0503-7CFDStenosisFractional flow reserve
spellingShingle R. Agujetas
M. R. González-Fernández
J. M. Nogales-Asensio
J. M. Montanero
Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve
BioMedical Engineering OnLine
CFD
Stenosis
Fractional flow reserve
title Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve
title_full Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve
title_fullStr Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve
title_full_unstemmed Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve
title_short Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve
title_sort numerical analysis of the pressure drop across highly eccentric coronary stenoses application to the calculation of the fractional flow reserve
topic CFD
Stenosis
Fractional flow reserve
url http://link.springer.com/article/10.1186/s12938-018-0503-7
work_keys_str_mv AT ragujetas numericalanalysisofthepressuredropacrosshighlyeccentriccoronarystenosesapplicationtothecalculationofthefractionalflowreserve
AT mrgonzalezfernandez numericalanalysisofthepressuredropacrosshighlyeccentriccoronarystenosesapplicationtothecalculationofthefractionalflowreserve
AT jmnogalesasensio numericalanalysisofthepressuredropacrosshighlyeccentriccoronarystenosesapplicationtothecalculationofthefractionalflowreserve
AT jmmontanero numericalanalysisofthepressuredropacrosshighlyeccentriccoronarystenosesapplicationtothecalculationofthefractionalflowreserve