EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITY

The use of high quality nutrient media comprising protein hydrolysates as the main components for maintaining their nutrient value is a critical prerequisite for appropriate fnal product preparation in FMD vaccine biotechnology. The incoming control of raw materials, in particular testing blood prot...

Full description

Bibliographic Details
Main Authors: M. N. Guseva, M. I. Doronin, M. A. Shevchenko, D. V. Mikhalishin, A. A. Shishkova
Format: Article
Language:English
Published: Da Vinci Media 2019-04-01
Series:Ветеринария сегодня
Subjects:
Online Access:https://veterinary.arriah.ru/jour/article/view/402
_version_ 1797224860523429888
author M. N. Guseva
M. I. Doronin
M. A. Shevchenko
D. V. Mikhalishin
A. A. Shishkova
author_facet M. N. Guseva
M. I. Doronin
M. A. Shevchenko
D. V. Mikhalishin
A. A. Shishkova
author_sort M. N. Guseva
collection DOAJ
description The use of high quality nutrient media comprising protein hydrolysates as the main components for maintaining their nutrient value is a critical prerequisite for appropriate fnal product preparation in FMD vaccine biotechnology. The incoming control of raw materials, in particular testing blood protein hydrolysates of different batches for their quality, is of considerable importance. Currently, there are different methods for the determination of hydrolysate efcacy using cell cultures and unicellular organisms as test systems. We used suspended baby hamster kidney (ВНК-21) cell line as a model for testing blood protein hydrolysates in the raw materials intended for FMD vaccine production for their biological activity and toxicity. The validation of the proposed method was carried out to confrm the reliability of the test results obtained. The following main validation characteristics were determined through testing 560 blood protein hydrolysate samples: trueness, specifcity, sensitivity, as well as precision under repeatability and reproducibility conditions. The validation results for the proposed method demonstrated high reliability (Fisher’s criterion – 0.021; ≤0.050) and full compliance with acceptance criteria.
first_indexed 2024-03-09T02:49:02Z
format Article
id doaj.art-30718f4a50bb4d1cb2b08bc3c5cb041a
institution Directory Open Access Journal
issn 2304-196X
2658-6959
language English
last_indexed 2024-04-24T13:59:50Z
publishDate 2019-04-01
publisher Da Vinci Media
record_format Article
series Ветеринария сегодня
spelling doaj.art-30718f4a50bb4d1cb2b08bc3c5cb041a2024-04-03T12:48:49ZengDa Vinci MediaВетеринария сегодня2304-196X2658-69592019-04-0101515710.29326/2304-196X-2019-1-28-51-57398EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITYM. N. Guseva0M. I. Doronin1M. A. Shevchenko2D. V. Mikhalishin3A. A. Shishkova4FGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirFGBI "ARRIAH", VladimirThe use of high quality nutrient media comprising protein hydrolysates as the main components for maintaining their nutrient value is a critical prerequisite for appropriate fnal product preparation in FMD vaccine biotechnology. The incoming control of raw materials, in particular testing blood protein hydrolysates of different batches for their quality, is of considerable importance. Currently, there are different methods for the determination of hydrolysate efcacy using cell cultures and unicellular organisms as test systems. We used suspended baby hamster kidney (ВНК-21) cell line as a model for testing blood protein hydrolysates in the raw materials intended for FMD vaccine production for their biological activity and toxicity. The validation of the proposed method was carried out to confrm the reliability of the test results obtained. The following main validation characteristics were determined through testing 560 blood protein hydrolysate samples: trueness, specifcity, sensitivity, as well as precision under repeatability and reproducibility conditions. The validation results for the proposed method demonstrated high reliability (Fisher’s criterion – 0.021; ≤0.050) and full compliance with acceptance criteria.https://veterinary.arriah.ru/jour/article/view/402blood protein hydrolysatebiological activitytoxicityspecifcitytest-system sensitivitytrueness of methodsprecision
spellingShingle M. N. Guseva
M. I. Doronin
M. A. Shevchenko
D. V. Mikhalishin
A. A. Shishkova
EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITY
Ветеринария сегодня
blood protein hydrolysate
biological activity
toxicity
specifcity
test-system sensitivity
trueness of methods
precision
title EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITY
title_full EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITY
title_fullStr EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITY
title_full_unstemmed EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITY
title_short EVALUATION OF SUITABILITY OF METHODS FOR TESTING BLOOD PROTEIN HYDROLYSATES FOR THEIR BIOLOGICAL ACTIVITY AND TOXICITY
title_sort evaluation of suitability of methods for testing blood protein hydrolysates for their biological activity and toxicity
topic blood protein hydrolysate
biological activity
toxicity
specifcity
test-system sensitivity
trueness of methods
precision
url https://veterinary.arriah.ru/jour/article/view/402
work_keys_str_mv AT mnguseva evaluationofsuitabilityofmethodsfortestingbloodproteinhydrolysatesfortheirbiologicalactivityandtoxicity
AT midoronin evaluationofsuitabilityofmethodsfortestingbloodproteinhydrolysatesfortheirbiologicalactivityandtoxicity
AT mashevchenko evaluationofsuitabilityofmethodsfortestingbloodproteinhydrolysatesfortheirbiologicalactivityandtoxicity
AT dvmikhalishin evaluationofsuitabilityofmethodsfortestingbloodproteinhydrolysatesfortheirbiologicalactivityandtoxicity
AT aashishkova evaluationofsuitabilityofmethodsfortestingbloodproteinhydrolysatesfortheirbiologicalactivityandtoxicity